Key features
- Log and trend measurements to pinpoint intermittent faults
- Transmit results wirelessly via the Fluke Connect® Measurements app
- Create and send reports from the field
- Stay safe and away from the arc flash zone with Bluetooth connectivity to Apple and Android devices
The Fluke 376 FC model is the direct replacement for the Fluke 376 clamp meter.
General specifications
-
AC current via jaw: 999.9 A
-
Resolution: 0.1 A
-
Accuracy: 2% ±5 digits (10 Hz to 100 Hz)
-
Accuracy: 2.5% ± 5 digits (100 to 500 Hz)
-
Crest factor (50/60 Hz): 3 at 500 A
-
Crest factor (50/60 Hz): 2.5 at 600 A
-
Crest factor (50/60 Hz): Add 2% for C.F. >2
-
AC current via flexible current probe: 2,500 A
-
Resolution: 0.1 A (≤ 600 A)
-
Resolution: 1 A (≤ 2500 A)
-
Accuracy: 3 % ± 5 digits (5 - 500 Hz)
-
Crest factor (50/60Hz): 3.0 at 1,100 A
-
Crest factor (50/60Hz): 2.5 at 1,400 A
-
Crest factor (50/60Hz): 1.42 at 2,500 A
-
Crest factor (50/60Hz): Add 2% for C.F. > 2
Position sensitivity
- i2500-10 Flex
- i2500-18 Flex
-
Distance from optimum position: 12.7 mm (0.5 in)
-
Distance from optimum position: 35.6 mm (1.4 in)
-
Error: ±0.5 %
-
Error: ±0.5 %
DC current
-
Range: 999.9 A
-
Resolution: 0.1 A
-
Accuracy: 2% ±5 digits
AC voltage
-
Range: 1000 V
-
Resolution: 0.1 V (≤600.0 V)
-
Resolution: 1 V (≤1000 V)
-
Accuracy: 1.5% ±5 digits (20 Hz to 500 Hz)
DC voltage
-
Range: 1000 V
-
Resolution: 0.1 V (≤600.0 V)
-
Resolution: 1 V (≤1000 V)
-
Accuracy: 1% ±5 digits
DC mV
-
Range: 500.0 mV
-
Resolution: 0.1 mV
-
Accuracy: 1% ±5 digits
Frequency via jaw
-
Range: 5.0 Hz to 500.0 Hz
-
Resolution: 0.1 Hz
-
Accuracy: 0.5% ±5 digits
-
Trigger level: 5 Hz to 10 Hz, ≥10 A
-
Trigger level: 10 Hz to 100 Hz, ≥5 A
-
Trigger level: 100 Hz to 500 Hz, ≥10 A
Frequency via flexible current probe
-
Range: 5.0 Hz to 500.0 Hz
-
Resolution: 0.1 Hz
-
Accuracy: 0.5% ±5 digits
-
Trigger level: 5 Hz to 20 Hz, ≥25 A
-
Trigger level: 20 Hz to 100 Hz, ≥20 A
-
Trigger level: 100 Hz to 500 Hz, ≥25 A
Resistance
-
Range: 60 kΩ
-
Resolution: 0.1 Ω (≤600 Ω)
-
Resolution: 1 Ω (≤6000 Ω)
-
Resolution: 10 Ω (≤60 kΩ)
-
Accuracy: 1% ±5 digits
Capacitance
-
Range: 1,000 μF
-
Resolution: 0.1 μF (≤ 100 μF)
-
Resolution: 1 μF (≤ 1000 μF)
-
Accuracy: 1% ±4 digits
Mechanical specifications
-
Maximum voltage between any terminal and earth ground: 1000 V
-
Batteries: 2 AA, NEDA 15A, IEC LR6
-
Operating temperature: -10 to +50 °C
-
Storage temperature: -40 °C to +60 °C
-
Operating humidity: ≤90% RH (at 10 °C to 30 °C)
-
Operating humidity: ≤75% RH (at 30 °C to 40 °C)
-
Operating humidity: ≤45% RH (at 40 °C to 50 °C)
-
Operating altitude: 2,000 m
-
Storage altitude: 12,000 m
-
Size (L x W x H): 249 x 85 x 45 mm
-
Weight: 395 g
-
Jaw opening: 34 mm
-
Flexible current probe diameter: 7.5 mm
-
Flexible current probe cable length: 1.8 m
Safety
-
IEC 61010-1: Pollution degree 2
-
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
-
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
-
IP Rating: IEC 60529: IP30, in standby
-
Radio frequency certification FCC ID: T68-FBLE IC:6627A-FBLE
Electromagnetic compatibility (EMC)
-
International: IEC 61326-1: portable, electromagnetic environment, IEC 61326-2-2
-
CISPR 11: Group 1, Class A
-
Group 1: The equipment intentionally generates or uses conductively coupled radio frequency energy that is necessary for the internal functioning of the equipment.
-
Class A: The equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network which supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments, due to conducted and radiated disturbances. Emissions may be generated that exceed the levels required by CISPR 11 when the equipment is connected to a test object.
-
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
-
Class A: This equipment complies with the requirements for industrial electromagnetic wave equipment and the seller or user should be aware of this. This equipment is intended for use in commercial, not domestic, environments.
-
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients
Add 0.1 x specified accuracy for each degree Celsius above 28 °C or below 18 °C
Measurement uncertainty assumes the presence of a primary conductor centered in an optimum position, with no external magnetic or electric field, and within the operating temperature range.