Wishlist

Deep Cycle Lithium Battery, 12.8 Vdc 100Ah LiFePO4 Metal Case, Solar, 100 A Maximum Discharge

  • $ 7,199.00
  • Brand: EPCOM POWER LINE BY RITAR
  • Availability: Out of stock
  • SKU: RLFP128100AMAX

Important Information The charging and discharging of this Lithium (LiFePO4) battery must be done in accordance with the parameters in the product specification. For solar power systems, it is recommended...

Tags: camera , categoria:Videovigilancia , marca:EPCOM POWER LINE BY RITAR , proveedor:Syscom , sku:RLFP128100AMAX , supplier:Syscom , surveillance , syscom , videovigilancia

Important Information

  • The charging and discharging of this Lithium (LiFePO4) battery must be done in accordance with the parameters in the product specification.
  • For solar power systems, it is recommended to use an EPEVER XTRA-XXXX-N or TRACER-XXXX-AN series charge controller; parameter programming for the (LiFePO4) battery is required.
Recommended Models
  • XTRA-2210N - 20A 12/24V MPPT Solar Controller, 100Vdc Voc
  • XTRA-3210N - 30A 12/24V MPPT Solar Controller, 100Vdc Voc
  • XTRA-4210N - 40A 12/24V MPPT Solar Controller, 100Vdc Voc
  • XTRA-4210N-XDS2-LI - 40A 12/24V MPPT Solar Controller, 100Vdc Voc
Documentation
  • Manual-Lithium-iron-phosphate-(LiFePO4)_
  • XTRA-XXXX-N Controller Parameter Programming for Lithium Battery (LiFePO4)_R2
Technical Specifications
  • Capacity: 100 Ah
  • Nominal Voltage: 12.8 Vdc
  • Cut-off Voltage: 11.2 Vdc
  • Normal Discharge Current: 100 A
  • Maximum Discharge Current: 100 A
  • Operating Temperature: -20°C to +60°C
  • Weight: 14 kg
  • Dimensions: 400 x 250 x 80 mm
Charging Parameters
  • Charging Mode: CC/CV
  • Charge Cycle Voltage: 14.4 Vdc
  • Float Voltage: 13.5 Vdc
  • Charging Current: 30 A
Precautions
  • Do not short-circuit terminals or reverse polarity
  • Do not disassemble or modify the battery
  • Keep the battery out of reach of children
  • Do not expose the battery to temperatures above 60°C
  • Do not use in vehicle starting systems
  • Do not connect more than 4 in parallel
  • Do not use in systems above 48 Vdc

Technical Support

For technical support, please contact our Engineering department