3m x 30cm Guyed Tower Section, Electrolytic Galvanized, Up to 30m Elevation. Dry Zones.
- $ 2,399.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: STZ-30
Highlights Product manufactured under standard: ISO 9001:2015 Each section is manufactured using CNC machinery Includes hardware for installation Recommended for Dry Zones (35% humidity or less) and free of corrosive...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:STZ-30 , supplier:Syscom , syscom
Highlights
- Product manufactured under standard: ISO 9001:2015
- Each section is manufactured using CNC machinery
- Includes hardware for installation
- Recommended for Dry Zones (35% humidity or less) and free of corrosive agents such as salt spray or other chemicals that accelerate the oxidation process
- Complies with electrolytic galvanizing standard: ASTMB-633
Physical Characteristics
- Maximum Load: 200 kg
- Maximum Height: 30 m (10 sections)
- Wind Resistance: 200 km/hr
- Material: 7/8' industrial tube (18 gauge)
- Diagonal Bracing (Zig-zag): 5/16' round
- Nipple: 10 cm
- Face width: 30 cm
- Weight: 12.5 kg
- Dimensions: 3 m length
- Structure material: Steel (A-36)
- Maximum load recommendations must be evaluated in conjunction with the engineering department
- Installation of dishes without a Radome is not recommended
- Anti-corrosive protection: Electrolytic galvanizing (ASTMB-633)
Application
- Point-to-Point systems
- Point-to-Multipoint systems
- Cellular signal amplification
- Lightning rod systems
- Base repeater radios
- Monitoring points
- Lighting
- Emergency audible signaling
- And more
Key Technical Notes
- Ensure installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- All dish antennas must use a radome as an accessory to reduce wind drag
- The use of dishes larger than 2 feet (60 cm) in diameter is not recommended on this tower (check with engineering)
- The stated weight is for the equipment without accessories and without packaging
- Towers can be purchased in complete kits VIEW TOWER KITS
Warning
- Electrolytic galvanizing is not recommended for humid areas, saline and/or corrosive environments such as coasts, dams, or industrial parks with gas discharge VIEW AREA MAP
- The tower must be painted in accordance with (at minimum) the CFE D8500-02 specification (7 symmetrical stripes, alternating orange and white, starting and ending with orange)
- Must include night lighting, at least two fixtures, one in the middle and one at the top
- Removing basic installation components will cause instability or excessive tower torsion
- Local municipal regulations must be consulted to ensure a correct and legal tower installation
- We recommend following the guy wire installation recommendations at all times: VIEW GUY WIRE INSTALLATION DIAGRAM