Wishlist

50 kVA UPS / Online Double Conversion / 3-Phase 200-240 Vac / PF 1.0 / Up to 6 in Parallel / Hardwired Terminal

  • $ 385,299.00
  • Brand: LinkedPro
  • Availability: In stock
  • SKU: LP50KYDC

LINKEDPRO BY EPCOM · LP50KYDC · Three-Phase UPS Power without compromise. 50 kVA of pure backup with 1.0 power factor. Double conversion, 94% efficiency, and up to 6 units in...

Tags: categoria:Redes e IT , marca:LINKEDPRO BY EPCOM , proveedor:Syscom , sku:LP50KYDC , supplier:Syscom , syscom

LINKEDPRO BY EPCOM · LP50KYDC · Three-Phase UPS

Power without compromise.

50 kVA of pure backup with 1.0 power factor. Double conversion, 94% efficiency, and up to 6 units in parallel with shared batteries. For the data center that cannot afford downtime.

LP50KYDC
50 kVA
Capacity
PF 1.0
Power factor
94%
Efficiency
0 ms
Transfer
6x
Parallel
132–275V
Input range
Real Power

Every watt counts. And here, they all do.

1.0 Power factor: 50 kVA means 50 real kW. No degradation factor, no fine print. The 3-level inverter delivers every watt with 94% efficiency, even under unbalanced, inductive, or capacitive loads.

THDi ≤3% · THDv ≤2% · Crest factor 3:1

LP50KYDC
Efficiency

Heat belongs in the AC bill.

3-level inverter technology with over 94% efficiency. Less thermal dissipation, less load on the equipment room HVAC. The smart fan adjusts speed according to load: it only spins fast when needed.

Noise <66 dB · 0–40 °C · Up to 1500 m without derating

Scalability

50 kVA today. 300 tomorrow.

Up to 6 units in redundant parallel with shared batteries. The system grows with your infrastructure without replacing equipment. The Power Walk-In function smooths the start-up with a generator: no tripped breakers, no stress on the plant.

16–26 batteries per group · 60 A charging current · ±192 to ±312 Vdc

LP50KYDC
Total Protection

Zero milliseconds. That is the promise.

0 ms transfer between grid and battery. Multilayer protection against short circuit, overload, overtemperature, excessive discharge, and fan failure. When the outside world fails, the LP50KYDC doesn't even blink.

Overload: 110% 60 min · 125% 10 min · 150% 1 min · >150% 1.2 s

Applications

Designed for where there is no margin for error.

Data Center
N+1 backup for server racks and SAN storage.
Hospitals
Uninterruptible power for imaging equipment and operating rooms.
Industry
Protection for PLCs, drives, and critical process control.
Telecom
Telephone exchanges, radio links, and communication towers.
Specifications

The numbers that matter.

Input
Nominal voltage: 208/120V or 220/127V (3Ph+N+PE)
Range: 132–275 Vac (50% load), 176–275 Vac (100%)
Frequency: 40–70 Hz
THDi: ≤3%
Input PF: ≥0.99
Output
Voltage: 208/120V or 220/127V
Regulation: ±1%
Frequency: 50/60 Hz ±0.02% (battery)
THDv: ≤2% linear, ≤5% non-linear
Crest factor: 3:1
Efficiency: >94%
Overload: 110% 60 min, 125% 10 min, 150% 1 min
Batteries
Configuration: 16–26 batteries per group
Voltage: ±192 to ±312 Vdc
Charging current: 60 A
Type: External (batteries not included)
Transfer: 0 ms
Physical and Certifications
Dimensions: 442 x 850 x 1200 mm
Weight: 165 kg
Temperature: 0–40 °C
Humidity: 0–95% non-condensing
Altitude: <1000 m (>1500 m derating)
Noise: <66 dB
Safety: UL 1778, CSA 22.2-107.3-14
EMC: FCC Part 15 Subpart B, ANSI C63.4
Efficiency: Energy Star 2.0
LINKEDPRO BY EPCOM

3-year warranty. Full coverage.

USB, RS232, RS485, SNMP, dry contact, and smart slot communication. Power Walk-In for soft start with generator. Tower type, not rack-mountable. External batteries are quoted separately.

Part number: PWRLP30KYDC · Technical support: ingenieria@syscom.mx

]]>