{"product_id":"accesorio-de-sellado-de-aire-cool-boot®-para-entradas-de-cable-por-piso-falso-con-retardante-de-llama-y-disipador-electrostatico-de-304-8-x-203-2-mm","title":"Cool Boot® Air Sealing Accessory, for Raised Floor Cable Openings, flame retardant and electrostatic dissipative, 304.8 x 203.2 mm","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDesigned for hot aisle\/cold aisle systems\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eReduces airflow, improves equipment cooling\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e304.8 mm total width for precise entry\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eOperational range: -40°C to 60°C\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eComplies with RoHS environmental regulations\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eTechnical Specifications\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eTotal width:\u003c\/strong\u003e 304.8 mm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eTotal depth:\u003c\/strong\u003e 15.2 mm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eTotal height:\u003c\/strong\u003e 203.2 mm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -40°C to 60°C\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Electrostatic dissipative and flame retardant polycarbonate\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e RoHS, NEC Article 645 Section 5(D)(4), UL94 V-0\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eApplications\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCooling optimization in data centers\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAirflow control in hot\/cold aisles\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSealing of raised floor cable entries\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCompatibility with PatchRunner™ and NetRunner™ systems\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIntegration with Net-Access™ Cabinet\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eMechanical Properties\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eLow-profile design:\u003c\/strong\u003e \u0026lt; 18 mm above floor\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCable protection:\u003c\/strong\u003e Covered inner edge\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Screw holes\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eCable Capacity\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCat. 6A (0.300'):\u003c\/strong\u003e 447 cables\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCat. 6\/6A-SD (0.240'):\u003c\/strong\u003e 698 cables\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCat. 5e (0.225'):\u003c\/strong\u003e 794 cables\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eCompatibility\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePatchRunner™ Vertical Cable Managers\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eNetRunner™ High-Capacity Vertical Cable Managers\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eNet-Access™ Cabinet (models N8512B, N8519B, S8512B, etc.)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eKey Benefits\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMinimizes uncontrolled airflow\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProtects against dust and debris accumulation\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAdaptable design for new and existing installations\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEasy installation without moving infrastructure\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFire-resistant and ESD materials\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eDimensions\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eTotal dimensions:\u003c\/strong\u003e 304.8 x 203.2 mm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRequired cutout:\u003c\/strong\u003e 266.7 x 158.8 mm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eEffective dimensions:\u003c\/strong\u003e 259.1 x 158.8 mm\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eCertifications\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRoHS compliant\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eConforms to NEC Article 645 Section 5(D)(4)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eUL94 V-0 materials\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFAR 25.853 flame-resistant fabric\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"PANDUIT","offers":[{"title":"Default Title","offer_id":62837102018719,"sku":"RFG12X8SMY","price":2899.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/RFG12X8SMY-p.png?v=1784917778","url":"https:\/\/store.glaretum.com\/en\/products\/accesorio-de-sellado-de-aire-cool-boot%c2%ae-para-entradas-de-cable-por-piso-falso-con-retardante-de-llama-y-disipador-electrostatico-de-304-8-x-203-2-mm","provider":"Glaretum","version":"1.0","type":"link"}