{"product_id":"base-para-torre-seccion-stz-30-galvanizada-por-electrolisis","title":"Base for STZ-30 tower section, electro-galvanized.","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduction compliant with recognized ISO 9000 standards\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRobust 1\/4\" steel base plate\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eElectrolytic galvanized 3\/4\" steel nipple\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDesigned for specialized concrete installation\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRequires engineering consultation for roof installations\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eTechnical Specifications\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e 1\/4\" steel base plate\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e 3\/4\" steel nipple\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eGalvanization:\u003c\/strong\u003e Electrolytic\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eTechnical Notes\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 14px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower base is designed to be installed on a concrete foundation specifically prepared for the load of the tower to be built\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFor ground-level installation, the provided reference can be used as an example diagram\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFor roof installations, it is recommended to consult a civil engineer who can ensure the stability of the structure where it will be installed\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInstallation Notes\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 14px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eTowers with stabilizers are recommended for installations with heavy weight loads, large antenna surface loads, and strong wind currents\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFor the calculation of extra guy wires on towers with stabilizers, it is assumed that the stabilizer replaces the flange located at 3\/4 of the tower height or the one closest to this height\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIt is always recommended to install obstruction lights\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eGuy wire lengths are calculated to place the anchors at 70% of the total tower height\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eInstallation must be performed only by experts\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eApplications\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSpecialized concrete installations\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSupports heavy weight loads\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHigh resistance to wind currents\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRoof installation with civil engineer consultation\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eRecommendations\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eConduct a soil resistance study\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eInstall anchors at 70% of the total height\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eReplace ground anchors with wall anchors depending on the application\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eDimensions\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHeight: 3m to 60m (various models)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnchoring distances: See tables by model\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSelection Tables\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cp style=\"margin: 0 0 10px 0; font-size: 14px; color: inherit;\"\u003eComponent selection varies according to tower height and specific requirements. Tables available for:\u003c\/p\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eBasic and stabilizer towers\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDifferent models (03ZT, 53ZT, 54ZT)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHeights from 3m to 60m\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eComponents by height level\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eComponents by Height\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cp style=\"margin: 0 0 10px 0; font-size: 14px; color: inherit;\"\u003eThe tables provide detailed information on components required based on height:\u003c\/p\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMaterial quantities\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnchoring distances\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFlange installation heights\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eGuy wire configuration\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828318490783,"sku":"SBA-30","price":899.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/SBA30-p.png?v=1783707988","url":"https:\/\/store.glaretum.com\/en\/products\/base-para-torre-seccion-stz-30-galvanizada-por-electrolisis","provider":"Glaretum","version":"1.0","type":"link"}