{"product_id":"bobina-de-cable-utp-305-metros-1000-pies-cat-6-24-awg-color-negro-uso-en-exterior-100-cobre-aplicaciones-de-cctv-y-redes-de-datos","title":"UTP Cable Spool 305 Meters (1000 Feet) \/ Cat 6 (24 AWG) \/ Black Color \/ Outdoor Use \/ 100% Copper \/ CCTV and Data Network Applications","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003c!-- Main image --\u003e\u003cdiv style=\"width: 100%; margin-bottom: 30px;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/DS1LN5ES\/158799-banner3.png\" alt=\"Main banner\" class=\"fr-fic fr-dii\"\u003e\u003c\/div\u003e\n\n\u003c!-- Main features --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eMain features\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCable for \u003cstrong\u003eVoice\/Data and Video networks\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\u003cstrong\u003e305m spool\u003c\/strong\u003e\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eThis is a UTP (Unshielded Twisted Pair) cable\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eRecommended for Megapixel IP CCTV\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eRecommended for data networks\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eRecommended for wireless networks\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003ePoE 802.af\/at applications\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003e100% copper\u003c\/strong\u003e conductors (wires)\n\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFor \u003cstrong\u003eoutdoor\u003c\/strong\u003e installations of houses, offices, buildings, etc.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEach conductor is \u003cstrong\u003e24 (AWG)\u003c\/strong\u003e gauge\n\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eApprovals: ANSI\/TIA-568.2-D, IEC61156, ISO\/IEC11801\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eQuality verified by Fluke brand equipment\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eExternal cable diameter: \u003cstrong\u003e0.515± 0.01 mm 24AWG\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFrequency: 250 MHz\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eColor: Black\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eMaterial: PVC (complies RoHS), CM\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eOperating temperature: \u003cstrong\u003e-20ºC to 50ºC\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTwisted pair cable (4 pairs)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eRecommended connector model \u003ca href=\"https:\/\/www.syscom.mx\/producto\/LP-KJ-6A-17U-LINKEDPRO-BY-EPCOM-192972.html\" style=\"color: inherit; text-decoration: underline;\"\u003eLP-KJ-6A-17U\u003c\/a\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\n\n\u003c!-- Separator --\u003e\u003chr style=\"border: 0; border-top: 1px solid rgba(150,150,150,0.3); margin: 30px 0;\"\u003e\n\n\u003c!-- General characteristics --\u003e\u003ch2 style=\"text-align: center; font-size: 20px; margin-bottom: 25px; color: inherit;\"\u003eGeneral characteristics regarding cable construction\u003c\/h2\u003e\n\n\u003c!-- Content with image and text --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/DS1LN5EOUU\/E\/174448-par_trenzado.png\" alt=\"Twisted pair cable\" class=\"fr-fic fr-dii\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 18px; margin-top: 0; color: inherit;\"\u003eWhat is balanced twisted pair cable used for?\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 14px; color: inherit;\"\u003eBalanced twisted pair \u003cstrong\u003eis used to cancel or decrease interference\u003c\/strong\u003e, improving data transmission. In other words, for telecommunications it implies a great advantage, because \u003cstrong\u003eit makes the quality of data transmission and reception maintain high quality\u003c\/strong\u003e or reduces to the maximum everything that could interfere. \u003cstrong\u003eThe twisting of the pairs is used for this, decreasing crosstalk and increasing power\u003c\/strong\u003e.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Differences between categories --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 18px; margin-top: 0; color: inherit;\"\u003eDifferences between cable performance categories\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 14px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eWhen talking about bandwidth\u003c\/strong\u003e, it is the part used in the electromagnetic spectrum and \u003cstrong\u003eis measured in MHz\u003c\/strong\u003e; what refers to \u003cstrong\u003eGbps\u003c\/strong\u003e is the \u003cstrong\u003edata transmission speed (it is the bits per second)\u003c\/strong\u003e.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eThe term channel width \u003cstrong\u003eDOES NOT EXIST\u003c\/strong\u003e in structured cabling.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/DS1LN5EOUU\/E\/174448-categor%C3%ADas.png\" alt=\"Cable categories\" class=\"fr-fic fr-dii\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Types of cable construction --\u003e\u003ch2 style=\"text-align: center; font-size: 20px; margin-bottom: 25px; color: inherit;\"\u003eThere are different types of cable construction, for example:\u003c\/h2\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eUTP\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\n\u003cp style=\"margin: 0 0 10px; font-size: 14px;\"\u003eUnshielded Twisted Pair\u003c\/p\u003e\n\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eIt is the cable that does not have shielding or screening\u003c\/p\u003e\n\n\u003cimg style=\"width: 100%; height: auto; border-width: medium; border-style: none; border-color: currentcolor; border-image: initial;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/DS1LN5EOUU\/E\/174448-utp.png\" alt=\"UTP\" class=\"fr-fic fr-dii\"\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eFTP\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\n\u003cp style=\"margin: 0 0 10px; font-size: 14px;\"\u003eFoiled Twisted Pair\u003c\/p\u003e\n\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eIt is the cable that has general shielding or screening for all wires\u003c\/p\u003e\n\n\u003cimg style=\"width: 100%; height: auto; border-width: medium; border-style: none; border-color: currentcolor; border-image: initial;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/DS1LN5EOUU\/E\/174448-f-utp.png\" alt=\"FTP\" class=\"fr-fic fr-dii\"\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSTP\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\n\u003cp style=\"margin: 0 0 10px; font-size: 14px;\"\u003eShielded Twisted Pair\u003c\/p\u003e\n\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eIt is the cable that has general mesh and shielding or screening for each pair of wires\u003c\/p\u003e\n\n\u003cimg style=\"width: 100%; height: auto; border-width: medium; border-style: none; border-color: currentcolor; border-image: initial;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/DS1LN5EOUU\/E\/174448-s-ftp.png\" alt=\"STP\" class=\"fr-fic fr-dii\"\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Final image --\u003e\u003cdiv style=\"width: 100%; margin-top: 30px;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/DS1LN5ES\/158799-bannerabajo.png\" alt=\"Bottom banner\" class=\"fr-fic fr-dii\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"HIKVISION","offers":[{"title":"Default Title","offer_id":62827181277343,"sku":"DS-1LN6OUTPE","price":4099.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/CP-HIKVISION-DS-1LN6OUTPE-0008d0.jpg?v=1793046295","url":"https:\/\/store.glaretum.com\/en\/products\/bobina-de-cable-utp-305-metros-1000-pies-cat-6-24-awg-color-negro-uso-en-exterior-100-cobre-aplicaciones-de-cctv-y-redes-de-datos","provider":"Glaretum","version":"1.0","type":"link"}