{"product_id":"detector-de-humo-por-aspiracion-cirrus-hybrid-4-tubos-1-zona","title":"Aspirating Smoke Detector | Cirrus Hybrid 4 Pipe 1 Zone","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\u003cdiv style=\"display: flex; flex-direction: column; gap: 20px;\"\u003e\n\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003ch1 style=\"font-size: 28px; margin: 0 0 10px 0; color: inherit;\"\u003eCirrus Hybrid\u003c\/h1\u003e\n\n\u003ch2 style=\"font-size: 20px; margin: 0; color: #2880b9; opacity: 0.9;\"\u003eAdvanced aspiration detection. The most sensitive technology on the market\u003c\/h2\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 15px; color: inherit;\"\u003e\u003cp style=\"margin: 0 0 15px 0;\"\u003eHistory tells us that, in reality, there are only two types of aspiration detection technology. These technologies are 'cloud chamber' aspiration detection, which identifies optically invisible fire particles, and 'optical' aspiration detection using laser or LED, which identifies small amounts of visible smoke. Cirrus HYBRID is the only aspiration detector available that identifies optically invisible fire particles through the use of the unique 'Cloud Chamber Detection' (CCD) technology. Depending on the materials burning—particularly in the many modern applications for aspiration detection systems—some fires burn with only a small amount of visible smoke, while others burn with larger volumes of visible smoke. Cirrus HYBRID also detects these 'smokier,' broad-spectrum types of fires. Early Warning Smoke Detection (EWSD) is provided using high-performance optical 'scattering chamber detectors' (SCD) that identify small and large smoke particles entering the detector. By utilizing the two most effective methods of aspiration system technologies (CCD and EWSD) in a single detector, the Cirrus HYBRID detector provides a device capable of detecting fire and smoke across the widest range of fire types. However, what makes this totally new and genuinely unique concept in aspiration fire and smoke detection technology so different is that these two technologies work independently of one another, and through the use of complex algorithms, they also interact together to provide truly intelligent alarm decision-making. The result of this synergy of technologies is a device that can verify true alarm conditions across the widest variety of fire types. An additional and equally important result of this synergy of technologies is the discrimination of unwanted or false alarms that have historically plagued so many optical-only aspiration detectors.\u003c\/p\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eFeatures\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCloud chamber technology as the only primary detection of its kind on the market\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eOptical scattering chamber detector as secondary detection\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eIndependent, intelligent alarm signal\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eWidest sensitivity range of any aspiration detector: 0% obs\/min - 20% obs\/min\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eHybrid 'Smart Signal' for verifying and discriminating false alarms\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e7\" color multifunction touch LCD screen\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eLive camera stream for up to 6 IP color cameras\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eOn-screen animated fault function\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eElectrical Specifications\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eVoltage: 20-29 VDC\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eConsumption: 16.8 W\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eElectrical draw: 500 mA with blower at 30% - 700 mA with blower at 100%\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eIP Rating: IP30\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAlarm indicators: Pre-alarm, Fire 1, Fire 2, Fire\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eCoverage\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eThe detector has an approximate coverage of 5,000 square meters (54,000 sq ft)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eApproximately 90m of pipe length (depends on software calculations)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTo protect open spaces, aspiration points are placed every 9 meters (30ft) when the height is no greater than 9 meters. When the height is greater than 9 meters, aspiration points are every 4.5 meters\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTo protect vents, air conditioners, HVAC, or the inside of ducts, sampling points are every 15cm – 30cm\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFor drop ceilings, a capillary is placed from the piping to the false ceiling. You would need to know the distance from the actual ceiling to the false ceiling to perform the calculations\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eSolution for Lithium Batteries\u003c\/h3\u003e\n\n\u003cdiv style=\"font-size: 15px; color: inherit;\"\u003e\n\n\u003cp style=\"margin-bottom: 15px;\"\u003eThe ideal solution for detecting fires in Lithium batteries\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 15px;\"\u003eThere are solutions on the market for detecting potential fires in Lithium battery banks that are difficult to program, install, and maintain, and the cost is excessively high. With Safe technology in aspiration detectors + Macurco detectors, it is possible to achieve reliable detection in these types of projects without making the solution prohibitively expensive:\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; justify-content: center; gap: 30px; margin-top: 20px;\"\u003e\n\n\u003cdiv style=\"width: 100%; max-width: 560px;\"\u003e\u003cdiv style=\"position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; margin-bottom: 30px;\"\u003e\u003cvideo style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" controls=\"controls\" width=\"300\" height=\"150\"\u003e \u003csource src=\"https:\/\/drive.google.com\/file\/d\/1jawzcoqMsRIDqfdQs4doO-0RtNdv20kd\/view?usp=sharing\"\u003e\u003c\/source\u003e\u003c\/video\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"width: 100%; max-width: 560px;\"\u003e\u003cdiv style=\"position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; margin-bottom: 30px;\"\u003e\u003ciframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: none;\" src=\"\/\/www.youtube.com\/embed\/XbuebxOPZJs\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e","brand":"SAFE FIRE DETECTION INC.","offers":[{"title":"Default Title","offer_id":62828172312735,"sku":"61986H4-FMUL4","price":165199.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/61986H4FMUL4-p.png?v=1783700746","url":"https:\/\/store.glaretum.com\/en\/products\/detector-de-humo-por-aspiracion-cirrus-hybrid-4-tubos-1-zona","provider":"Glaretum","version":"1.0","type":"link"}