{"product_id":"fibra-para-compuesto-sellador-60-gr","title":"Fiber for Sealant Compound (60 g).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e60 grams of fiber for increased strength\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCompatibility with multiple sealing compounds\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eReinforcement for sealing in industrial applications\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFibrous structure for better adhesion\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEasy to mix into existing compounds\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eTechnical Specifications\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Sealing in Class I, II, and III, Divisions 1 and 2 hazardous areas\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e With sealing compounds requiring fibrous reinforcement\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Special fiber for sealing compound\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eUse:\u003c\/strong\u003e To create an obstruction that prevents runoff during application\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eStandards:\u003c\/strong\u003e Designed to meet sealing requirements in classified areas\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eApplications\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eConduit sealing in hazardous areas\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProtection against gas and vapor passage\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePrevention of flame spread\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSealing in electrical systems\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eInstructions for Use\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePlace no more than 457 mm (18\") from heat-generating equipment\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFill 25% of the seal\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe cement thickness must not be less than the conduit diameter\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIn no case should the thickness be less than 16 mm (5\/8\")\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSealing Cement Properties\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSlight expansion upon application\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eResistant to solvents, acids, water, and oils\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eForms an airtight seal\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSpecific gravity: 3\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMelting point: 1300-1400°C\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003ePrecautions\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMay cause skin and eye irritation\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAvoid prolonged dust inhalation\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eUse of protective equipment is recommended\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not ingest, may cause digestive obstruction\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAvoid dust accumulation in work areas\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eComposition\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFused Calcium Aluminate 30-50%\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnhydrous Gypsum 5-20%\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCrystalline Silica Sand \u0026lt;5%\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePortland Cement \u0026lt;10%\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eClassification\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eClass I: Div. 1 and 2, groups A, B, C, D\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eClass II: Div. 1 and 2, groups E, F, G\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eClass III: Div. 1 and 2\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eStorage Recommendations\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eKeep product dry\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eStore in closed containers\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eWell-ventilated storage area\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePeriodic cleaning of work areas\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eAdditional Information\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRegulations:\u003c\/strong\u003e Complies with international safety standards\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e Electrical installations in classified areas\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003ePresentation:\u003c\/strong\u003e 60-gram pack\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eReference:\u003c\/strong\u003e Brochure RW 12 \/ 1908\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eManufacturing\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eProcess:\u003c\/strong\u003e 100% Domestic Manufacturing and Integration\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuality:\u003c\/strong\u003e Meets safety standards for hazardous areas\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eApproval:\u003c\/strong\u003e EYS Series Sections 6.1 and 6.2\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eUse:\u003c\/strong\u003e Conduit sealing in electrical systems\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eSafety Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eNFPA Rating:\u003c\/strong\u003e Health 2, Flammability 0, Instability 0\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCharacteristics:\u003c\/strong\u003e Non-flammable, non-combustible\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eReactions:\u003c\/strong\u003e Thermal decomposition at high temperatures produces sulfur oxides\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eProtective Equipment:\u003c\/strong\u003e Goggles, gloves, and respiratory protection\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eSafety Specifications\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eExposure Limits:\u003c\/strong\u003e Follow OSHA recommendations for components\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eDust Control:\u003c\/strong\u003e Minimize generation through adequate ventilation\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eSafe Handling:\u003c\/strong\u003e Use of NIOSH-approved respiratory protection\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eFirst Aid:\u003c\/strong\u003e Rinse with abundant water in case of skin\/eye contact\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"RAWELT","offers":[{"title":"Default Title","offer_id":62828114935967,"sku":"FB-06","price":1099.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/FB06-p.png?v=1783696958","url":"https:\/\/store.glaretum.com\/en\/products\/fibra-para-compuesto-sellador-60-gr","provider":"Glaretum","version":"1.0","type":"link"}