{"product_id":"fuente-de-poder-con-respaldo-12-o-24-vcc-4-a-48-w-8-salidas-para-control-de-acceso-entrada-115-vca","title":"Power Supply with Battery Backup, 12 or 24 VDC, 4 A, 48 W, 8 Outputs, For Access Control, 115 VAC Input","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInput\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e115VAC 60Hz input rated @ 3.5A.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003ePower supply input options:\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px; margin-left: 20px;\"\u003ea) One (1) common power input for ACM8 \/ ACM8CB and lock power (factory installed).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px; margin-left: 20px;\"\u003eb) Two (2) isolated power inputs: one (1) to power the ACM8 \/ ACM8CB and one (1) for lock accessory power (external power supply is required). (Current is determined by the connected power supply, which must not exceed 10A total).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEight (8) access control system trigger inputs.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInput Options\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003ea) Eight (8) normally open (NO) inputs.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eb) Eight (8) open collector inputs.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003ec) Any combination of the above.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eOutput\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e12VDC or 24VDC outputs.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e12VDC @ 4A supply current or 24VDC @ 3A supply current.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eClass 2 power-limited outputs.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEight (8) independently controlled outputs.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eOutput Options\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003ea) Eight (8) fail-safe and\/or fail-secure power outputs.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eb) Eight (8) form 'C' 5A rated relay outputs.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003ec) Any combination of the above.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEight (8) auxiliary power outputs (unswitched).\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eOutput Control\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEight (8) independently controlled outputs.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFuses are rated @ 3.5A.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFiltered and electronically regulated outputs (built-in power supply).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eThe ACM8 board main fuse is rated at 10A.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eSupervision\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAC fail supervision (form 'C' contacts). Notification trigger can be selected for 30 seconds (factory set) or 6 hours.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eLow battery and battery presence supervision (form 'C' contact).\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eFeatures\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFire alarm disconnect (latching or non-latching) can be individually selectable for any or all of the eight (8) outputs.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eWith battery backup capability.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eBattery not included.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSuggested batteries: PL4.512 \/ PL712 \/ PL912.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFire alarm disconnect input options:\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px; margin-left: 20px;\"\u003ea) Normally open (NO) or normally closed (NC) dry contact input.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px; margin-left: 20px;\"\u003eb) FACP signaling circuit polarity reversal input.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAlarm output relay indicates that FACP input is triggered (form 'C' contact rated 1A @ 28VDC, not evaluated by UL).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eShort circuit and thermal overload protection.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eVisual Indicators\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eShort circuit and thermal overload protection.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eRed LEDs indicate outputs are triggered (relays are energized).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eGreen LED indicates FACP disconnect is triggered.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAC input and DC output LED indicators.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eBattery backup.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAC input and DC output LED indicators.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eBuilt-in charger for sealed lead acid or gel type batteries.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAutomatic switch-over to standby battery when AC fails.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eZero voltage drop when unit switches over to battery backup (AC fail condition).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eBattery fail and battery presence supervision (form 'C' contact).\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eTemperature\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eOperating: 0ºC to 49ºC (32ºF to 120ºF).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eStorage: -20ºC to 70ºC (-4ºF to 158ºF).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eRelative humidity 85% +\/- 5%.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eBTU\/Hr. (approx.)\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e12VDC: 25 BTU\/Hr.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e24VDC: 37 BTU\/Hr.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eEnclosure\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eWall mount enclosure for indoor use.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAccommodates up to two (2) 12VDC\/12AH batteries.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDimensions 12.25\"W x 15.5\"H x 4.5\"D (311mm W x 394mm H x 114mm D).\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eWeight\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eProduct weight: 10.7 lbs. (4.85 kg).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eShipping weight: 12 lbs. (5.44 kg).\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\n\n\n\u003c\/div\u003e","brand":"ALTRONIX","offers":[{"title":"Default Title","offer_id":62826978771103,"sku":"AL400ULACM","price":10499.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/AL400ULACM-p.png?v=1783616778","url":"https:\/\/store.glaretum.com\/en\/products\/fuente-de-poder-con-respaldo-12-o-24-vcc-4-a-48-w-8-salidas-para-control-de-acceso-entrada-115-vca","provider":"Glaretum","version":"1.0","type":"link"}