{"product_id":"fuente-de-poder-de-10a-a-24vcc-alimenta-circuitos-nac","title":"10A 24VDC Power Supply - Powers NAC Circuits","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003c!-- Descripción general --\u003e\u003cdiv style=\"margin-bottom: 30px;\"\u003e\u003cp style=\"font-size: 15px; color: inherit; margin: 0 0 15px 0;\"\u003eThe PS Series is a line of remote power supplies from Fire•Lite Alarms and is a direct replacement for the FCPS-4FS6\/8 series. The FLPS6 is a 6-amp and the FL-PS10 is a 10-amp remote power supply. The power supply includes a battery charger that can be connected to any 12- or 24-volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (Notification Appliance Circuits) configured as Class B or Class A (requires the optional ZNAC-PS card) with multiple synchronization protocol options. The PS Series also provides auxiliary power, constant or resettable, suitable for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can house two 7 AH or 18 AH batteries and can charge batteries up to 33 AH in a separate cabinet.\u003c\/p\u003e\u003c\/div\u003e\n\n\u003c!-- Sección de características --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eFeatures\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eUp to five (6-amp model) or seven (10-amp model) power-limited output circuits that are independently configurable for:\u003c\/li\u003e\n\n\u003cul style=\"padding-left: 25px; margin-top: 5px; margin-bottom: 10px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eClass B and\/or Class A NACs\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eClass B and\/or Class A 24V resettable or non-resettable auxiliary power\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDoor holder power\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eConverts Class B wiring to Class A without losing any outputs using the ZNAC-PS converter card (sold separately)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eOptimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eConfigurable for ANSI® Temporal 3 or Temporal 4 coded output\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eUL-listed NAC synchronization using System Sensor®, Wheelock®, Gentex®, or AMSECO® devices\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSynchronization can be triggered from the FACP NAC\/remote sync\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eoutputs, cascaded power supply, or a single or multi-control module that can be housed inside the power supply cabinet\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAbility to cascade up to four power supplies\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTwo (6-amp model) or three (10-amp model) inputs\/control circuits that can be programmed to any output\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTwo Form-C normally closed trouble relays for AC Trouble and General Trouble; ground fault relay available on Canadian models only\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e6 or 10-amp full-load output, respectively, with a maximum of 3 A\/circuit\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eIndividual NAC trouble and power LEDs for diagnostic efficiency\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTrouble history modes for diagnostic support\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eWide-range End-of-Line supervision value (standard: 2K-27K ohms)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSelectable ground fault detection (enable or disable)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAC trouble report delay timer\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFully configurable via built-in DIP switches, no additional software required\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSelf-contained in a compact, locking steel gauge cabinet with a corrosion-resistant powder coat chip and scratch-resistant finish\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCabinet designed with ten double knockouts and a removable door for easy installation and wiring\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eIncludes integral battery charger capable of charging up to 33 AH batteries\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eThe cabinet can house two 7 AH or 18 AH batteries\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\n\n\u003c!-- Sección de estándares y códigos --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eStandards and Codes\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eNFPA 72 National Fire Alarm Code\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eUL Standard 864 for Control Units for Fire Alarm Systems (NAC expander mode), 10th edition\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eUL 1481 Power Supplies for Fire Alarm Systems\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eIBC 2009 (when using SEISKIT-MULTI-1)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCBC 2007 (when using SEISKIT-MULTI-1)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\n\n\u003c!-- Sección de listados y aprobaciones --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eAgency Listings and Approvals\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eUL Listed: S2424\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eULC Listed: S2424 (FL-PS6\/10C)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCSFM Approved: 7315-0075:0510\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFDNY Approved\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFM Approved\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp style=\"font-size: 14px; color: inherit; margin-top: 15px;\"\u003eThese listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or the listing may be in process. Consult the factory for the latest listing status.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\n\n\u003c!-- Separador final --\u003e\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\n\n\n\u003c\/div\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":62827159617695,"sku":"FL-PS10","price":14799.0,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/FLPS10-p.png?v=1783632036","url":"https:\/\/store.glaretum.com\/en\/products\/fuente-de-poder-de-10a-a-24vcc-alimenta-circuitos-nac","provider":"Glaretum","version":"1.0","type":"link"}