{"product_id":"kit-de-torre-arriostrada-de-piso-de-15-m-altura-con-tramo-stz35g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","title":"15m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wires not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 30px;\"\u003e \u003cdiv\u003e \u003cdiv style=\"text-align: center; margin-bottom: 20px;\"\u003e \u003cimg style=\"width: 100%; max-width: 300px; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/logotipos\/syscom_towers.png\" alt=\"SYSCOM TOWERS Logo\"\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 20px;\"\u003e \u003cdiv\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit; list-style: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under ISO 9001:2015 standards.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHigh elevation \/ Low cost.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e100% section-by-section assembly inspection.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHot-dip galvanized according to NMX-H-004-SCFI-2008.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIdeal for high-humidity coastal zones or industrial areas.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePhysical Characteristics\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit; list-style: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMaximum Axial Load: 350 kg.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHeight: 15 meters (5 sections).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eWind Resistance: 200 km\/h.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eApplication: Outdoor (Humid zones).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eIncludes the following components\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto; margin: 15px 0;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003cthead style=\"background-color: rgba(192, 57, 43, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e5\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/STZ-35G-SYSCOM-TOWERS-31577.html\" target=\"_blank\" rel=\"noopener\"\u003eSTZ35G\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e35 cm face width tower section.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SCZ-35-PG-SYSCOM-TOWERS-169014.html\" target=\"_blank\" rel=\"noopener\"\u003eSCZ35PG\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e35 cm tower top with lightning rod clamp.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SBZ-35G-SYSCOM-TOWERS-29193.html\" target=\"_blank\" rel=\"noopener\"\u003eSBZ35G\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e35 cm tower base.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SAB-45G-SYSCOM-TOWERS-29014.html\" target=\"_blank\" rel=\"noopener\"\u003eSAB45G\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eAnchor for 35\/45 tower base.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SJB-35G-SYSCOM-TOWERS-29955.html\" target=\"_blank\" rel=\"noopener\"\u003eSJB35G\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eGuy wire support clamp.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SAZ-45G-SYSCOM-TOWERS-29086.html\" target=\"_blank\" rel=\"noopener\"\u003eSAZ45G\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eFloor anchor for guy wire.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e12\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-14-HDG-SYSCOM-TOWERS-199560.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-14-HDG\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eThimble for guy wire\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e36\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-316-FJG-SYSCOM-TOWERS-199580.html\"\u003eNUDO-316-FJG\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/16' wire rope clip.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"color: #c0392b; font-weight: bold; margin: 15px 0;\"\u003eDoes not include guy wire. 115 meters of 3\/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.\u003c\/p\u003e \u003cp style=\"color: #c0392b; font-weight: bold; margin: 15px 0;\"\u003eDoes not include turnbuckles. 6 turnbuckles of 5\/8' x 9' (TEN5\/8X9OGJ or TEN5\/8X9OQJ) are recommended.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eComplementary accessories (Not included)\u003c\/h3\u003e \u003cp style=\"font-style: italic; margin: 15px 0;\"\u003e*Failure to use installation accessories such as clamps, tower base, tower anchor, or guy anchors is considered a voiding of the equipment warranty, and any additional modifications are the responsibility of the installer.\u003c\/p\u003e \u003cdiv style=\"margin: 20px 0;\"\u003e \u003ch4 style=\"color: #c0392b; font-size: 18px; margin-top: 0;\"\u003eSignaling\/Lighting System \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e:\u003c\/h4\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003cthead style=\"background-color: rgba(192, 57, 43, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/EI-GSL-SE-EPCOM-INDUSTRIAL-155623.html\" target=\"_blank\" rel=\"noopener\"\u003eEIGSLSE\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eAutonomous LED strobe with photocell, solar panel, and battery. Type L810.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/HLU-3R2-EPCOM-INDUSTRIAL-196712.html\" target=\"_blank\" rel=\"noopener\"\u003eHLU3R2\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eMounting for EIGSLSE obstruction light\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"font-size: 14px; font-style: italic; margin: 15px 0;\"\u003e*Signaling regulations dictate that the tower must be painted in 7 strips of equal size; 4 strips in reddish-orange and 3 in white.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"margin: 20px 0;\"\u003e \u003ch4 style=\"color: #c0392b; font-size: 18px; margin-top: 0;\"\u003eLifeline System \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e:\u003c\/h4\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003cthead style=\"background-color: rgba(192, 57, 43, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=SHE-LV-SYSCOM-TOWERS-29815\u0026amp;autodetect=shelv\"\u003eSHE-LV\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003ePair of mounting brackets\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=S-GULV-SYSCOM-TOWERS-29794\u0026amp;autodetect=sgul\"\u003eS-GULV\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eLine guide\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e18\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SRET318CAM-CAMESA-151126.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-338CAM\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8' cable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e6\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-38-FJG-SYSCOM-TOWERS-199587.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-38FJG\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8' forged rope clip\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-38-HDG-SYSCOM-TOWERS-199562.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-38-HDG\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8' thimble\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=TRY-ACC-SLIDER-Trylon-161793\u0026amp;autodetect=carro\"\u003eTRY-ACC-SLIDER\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e(Optional) Safety carriage for installer.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=SYS-USA7B-URREA-174988\u0026amp;autodetect=sysusa\"\u003eSYS-USA7B\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e(Optional) Suspension harness.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"font-size: 14px; font-style: italic; margin: 15px 0;\"\u003e*NOM-009 mandates the use of systems that arrest accidental falls on a structure.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"margin: 20px 0;\"\u003e \u003ch4 style=\"color: #c0392b; font-size: 18px; margin-top: 0;\"\u003eGrounding System Recommended for Tower and Mounted Equipment \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e:\u003c\/h4\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003cthead style=\"background-color: rgba(192, 57, 43, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\"\u003eTG45AB\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e45 A grounding electrode with electrode, filter, and H2Ohm compound\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\"\u003eS610\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003ePlastic access box.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\"\u003eTGCR11\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eEye connector\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\"\u003eTGAB18\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eRod connector\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGBUSG10-TOTAL-GROUND-75914.html\"\u003eTGBUSG10\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eGrounding bus bar with insulators, 1000A capacity (without cabinet)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 15px 0; font-size: 14px;\"\u003e*The use of 4 AWG jacketed copper wire (SLY-287-GRN) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"margin: 20px 0;\"\u003e \u003ch4 style=\"color: #c0392b; font-size: 18px; margin-top: 0;\"\u003eBasic Lightning Protection System Recommended for Tower \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e:\u003c\/h4\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid rgba(150,150,150,0.3);\"\u003e \u003cthead style=\"background-color: rgba(192, 57, 43, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGTDPC-TOTAL-GROUND-76020.html\"\u003eTGTDPC\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eLightning rod with aluminum mast (MASTIL1.2)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\"\u003eTG45AB\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e45 Amp electrode. With one bag of impedance improvement compound (H2OHM), compass, and level.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\"\u003eS610\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eSmall plastic access box.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/ANTIOX-TOTAL-GROUND-75931.html\"\u003eANTIOX\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eAerosol for terminal protection.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\"\u003eTGCR11\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eEye connector.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\"\u003eTGAB18\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eRod connector.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e10\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/TG-AC-114-TOTAL-GROUND-85849.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAC114\u003c\/a\u003e \u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eTower insulator.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 15px 0; font-size: 14px;\"\u003e*The dipole-type tip offers a 72° protection cone under the coil. Recommended for areas with low lightning incidence.\u003c\/p\u003e \u003cp style=\"margin: 15px 0; font-size: 14px;\"\u003e*2\/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.\u003c\/p\u003e \u003cp style=\"margin: 15px 0; font-size: 14px;\"\u003eSee the Physical Ground + Lightning Rod connection diagram in the following \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2019\/03\/27\/2ed55\/01REV02-DIPOLO%20CORONA%20Y%20EQUIPO%20EN%20TORRE.pdf\"\u003eDIAGRAM\u003c\/a\u003e.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"margin: 20px 0;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRecommendations\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit; list-style: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEnsure that the installation is performed by a trained professional.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan for checking guy wire tension and tightening hardware.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA stress analysis must be performed when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in an orange-red and white tone, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting work).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIt is recommended to illuminate the tower at least at the top with a red lamp.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"margin: 20px 0;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRepresentative Diagram: Guy Wire Installation Version 2.0\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" alt=\"Guy Wire Installation Diagram\"\u003e \u003c\/div\u003e \u003cdiv style=\"margin: 20px 0;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInstallation Images\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/ARRIOSTRADAS\/TORRES%20IMAGEN.png\" alt=\"Installation Images\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828327796895,"sku":"KTZ-35G-015","price":31899.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/KTZ35G015-p.png?v=1783708416","url":"https:\/\/store.glaretum.com\/en\/products\/kit-de-torre-arriostrada-de-piso-de-15-m-altura-con-tramo-stz35g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","provider":"Glaretum","version":"1.0","type":"link"}