{"product_id":"kit-de-torre-arriostrada-de-piso-de-21-m-altura-con-tramo-stz30g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","title":"21 m Floor-Mounted Guyed Tower Kit with STZ30G Hot-Dip Galvanized Section (guy wires not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003c!-- Logo --\u003e \u003cdiv style=\"text-align: center; margin: 30px 0;\"\u003e \u003cimg style=\"width: 100%; max-width: 300px; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/logotipos\/syscom_towers.png\" alt=\"Logo SYSCOM TOWERS\"\u003e \u003c\/div\u003e \u003c!-- Características Destacadas --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under ISO 9001:2015 standards.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHigh elevation \/ Low cost.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e100% assembly inspection section by section.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHot-dip galvanized in accordance with NMX-H-004-SCFI-2008.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIdeal for high-humidity coastal zones or industrial areas.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Características Físicas --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePhysical Characteristics\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMaximum Axial Load: 200 Kg.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHeight: 21 meters (7 sections).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eWind Resistance: 200 km\/hr.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eApplication: Outdoor (Humid zones).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Componentes incluidos --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eIncludes the following components\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0; color: inherit;\"\u003e \u003cthead style=\"background-color: rgba(150,150,150,0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e7\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/STZ-30G-SYSCOM-TOWERS-31574.html\" target=\"_blank\" rel=\"noopener\"\u003eSTZ30G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eTower section with 30 cm face width.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SCZ-30-PG-SYSCOM-TOWERS-169012.html\" target=\"_blank\" rel=\"noopener\"\u003eSCZ30PG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e30 cm tower top with set screw for lightning rod.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SBA-30G-SYSCOM-TOWERS-29104.html\" target=\"_blank\" rel=\"noopener\"\u003eSBA30G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eBase for 30 cm tower.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SAB-30G-SYSCOM-TOWERS-29012.html\" target=\"_blank\" rel=\"noopener\"\u003eSAB30G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eAnchor for tower base.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e4\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SJB-30G-SYSCOM-TOWERS-29952.html\" target=\"_blank\" rel=\"noopener\"\u003eSJB30G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eGuy wire attachment flange.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SAP-02G-SYSCOM-TOWERS-29055.html\" target=\"_blank\" rel=\"noopener\"\u003eSAP02G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eFloor anchor for guy wire.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e24\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-14-HDG-SYSCOM-TOWERS-199560.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-14-HDG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eThimble for guy wire\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e72\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-316-FJG-SYSCOM-TOWERS-199580.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-316-FJG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/16' wire rope clip.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003eDoes not include guy wire. 290 meters of 1\/8' guy wire (\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SRET318CAM-CAMESA-151126.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-318-CAM\u003c\/a\u003e) or larger diameters are recommended.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- No incluye tensores --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003cp style=\"margin: 0 0 10px; font-size: 14px; color: inherit;\"\u003eDoes not include turnbuckles. 12 turnbuckles of 1\/2' x 6' are recommended. (\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OGJ-SYSCOM-TOWERS-199554.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OGJ\u003c\/a\u003e or \u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OQJ-SYSCOM-TOWERS-199557.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OQJ\u003c\/a\u003e).\u003c\/p\u003e \u003cp style=\"margin: 10px 0; font-size: 14px; color: inherit;\"\u003e\u003cem\u003e* NOT using installation accessories such as flanges, tower base, tower anchor, or guy wire anchors is considered a forfeiture of the equipment warranty, and any additional adaptation is the sole responsibility of the installer.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Accesorios complementarios --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eComplementary accessories (Not included)\u003c\/h3\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003cstrong\u003eSignaling\/Lighting System (Not included)\u003c\/strong\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sistema de línea de vida --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eLifeline system (Not included)\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0; color: inherit;\"\u003e \u003cthead style=\"background-color: rgba(150,150,150,0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SHE-LV-SYSCOM-TOWERS-29815.html\" target=\"_blank\" rel=\"noopener\"\u003eSHE-LV\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003ePair of mounting brackets\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/S-GULV-SYSCOM-TOWERS-29794.html\" target=\"_blank\" rel=\"noopener\"\u003eS-GULV\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eLine guide\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e24\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SRET318CAM-CAMESA-151126.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-338CAM\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8' cable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e6\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-38-FJG-SYSCOM-TOWERS-199587.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-38FJG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8' forged wire rope clip\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-38-HDG-SYSCOM-TOWERS-199562.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-38-HDG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8' thimble\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/TRY-ACC-SLIDER2-Trylon-192532.html\" target=\"_blank\" rel=\"noopener\"\u003eTRY-ACC-SLIDER\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e(Optional) Safety slider for installer.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SYS-USA7B-URREA-174988.html\" target=\"_blank\" rel=\"noopener\"\u003eSYS-USA7B\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e(Optional) Suspension harness.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 15px 0; font-size: 14px; color: inherit;\"\u003e\u003cem\u003e* NOM-009 mandates the use of systems that prevent accidental falls on a structure.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Kit Pararrayo --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eNew! Lightning Rod Kit + Grounding with Cable. Brand: LINKEDPRO (Not included)\u003c\/h3\u003e \u003cp style=\"margin: 10px 0; font-size: 14px; color: inherit;\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/KLP-TZ21-PRO-LINKEDPRO-BY-EPCOM-192188.html\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eKLP-TZ21-PRO\u003c\/strong\u003e\u003c\/a\u003e. - All inclusive! Ideal for 21m towers with corona dipole, wiring, and electrodes.\u003c\/p\u003e \u003cp style=\"margin: 10px 0; font-size: 14px; color: inherit;\"\u003e\u003cem\u003eOr you can quote the following Grounding or Lightning Rod components individually:\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sistema de Tierra Física --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRecommended Grounding System for Tower and mounted equipment (Not included)\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0; color: inherit;\"\u003e \u003cthead style=\"background-color: rgba(150,150,150,0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e45 A grounding electrode with electrode, filter, and H2Ohm compound\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003ePlastic access box.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\" target=\"_blank\" rel=\"noopener\"\u003eTGCR11\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eEye connector\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eRod connector\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/TGBUSG10-TOTAL-GROUND-75914.html\" target=\"_blank\" rel=\"noopener\"\u003eTGBUSG10\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e1000A capacity ground bus bar with insulators (No cabinet)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 15px 0; font-size: 14px; color: inherit;\"\u003e* 4 AWG insulated copper cable (\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SLY-287-GRN-INDIANA-176933.html\"\u003eSLY-287-GRN\u003c\/a\u003e) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SL-Y-291-GRN-100-INDIANA-87721.html\"\u003eSLY-291-GRN\u003c\/a\u003e) can be used.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sistema de Pararrayos --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRecommended Basic Lightning Rod System for Tower (Not included)\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0; color: inherit;\"\u003e \u003cthead style=\"background-color: rgba(150,150,150,0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/TGTDPC-TOTAL-GROUND-76020.html\" target=\"_blank\" rel=\"noopener\"\u003eTGTDPC\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eLightning rod tip with aluminum mast (MASTIL1.2)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eSmall plastic access box.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/ANTIOX-TOTAL-GROUND-75931.html\" target=\"_blank\" rel=\"noopener\"\u003eANTIOX\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eTerminal protection spray.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\" target=\"_blank\" rel=\"noopener\"\u003eTGCR11\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eEye connector.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eRod connector.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e14\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: none;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAC-TOTAL-GROUND-76016.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAC\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eTower insulator.\u003c\/td\u003e \u003c\/tr\u003e   \u003c\/div\u003e \u003cp style=\"margin: 15px 0; font-size: 14px; color: inherit;\"\u003e*The dipole-type tip offers a 72° protection cone under the coil. Recommended for areas with low lightning incidence.\u003cbr\u003e *2\/0 gauge copper cable is recommended for integration (\u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/www.syscom.mx\/producto\/SLY-346-BLK-INDIANA-176872.html\"\u003eSLY-346-BLK\u003c\/a\u003e). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.\u003c\/p\u003e \u003cp style=\"margin: 15px 0; font-size: 14px; color: inherit;\"\u003eSee the Grounding + Lightning Rod connection diagram in the following \u003ca style=\"color: inherit; text-decoration: none;\" href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2019\/03\/27\/2ed55\/01REV02-DIPOLO%20CORONA%20Y%20EQUIPO%20EN%20TORRE.pdf\"\u003eDIAGRAM\u003c\/a\u003e.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Recomendaciones --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRecommendations\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 14px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEnsure the installation is performed by a trained professional.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan to check guy wire tension and tighten hardware.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in orange-red and white tones, in 7 stripes of equal height, starting and ending in orange-red (SYSCOM does not perform tower painting services).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIt is recommended to illuminate the tower at least at the tip with a red lamp.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Diagrama de Instalación --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRepresentative Diagram: Guy Wire Installation Version 2.0\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px; margin: 15px 0;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" alt=\"Guy Wire Installation Diagram\"\u003e \u003c\/div\u003e \u003c!-- Imágenes de Instalación --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInstallation Images\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px; margin: 15px 0;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/ARRIOSTRADAS\/TORRES%20IMAGEN.png\" alt=\"Installation Images\"\u003e \u003c\/div\u003e \u003c!-- Separador final --\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150,150,150,0.3); margin: 30px 0;\"\u003e ","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828327403679,"sku":"KTZ-30G-021","price":25399.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/KTZ30G021-p.png?v=1783708393","url":"https:\/\/store.glaretum.com\/en\/products\/kit-de-torre-arriostrada-de-piso-de-21-m-altura-con-tramo-stz30g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","provider":"Glaretum","version":"1.0","type":"link"}