{"product_id":"kit-de-torre-arriostrada-de-piso-de-21-m-altura-con-tramo-stz35g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","title":"21 m Guyed Ground Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wire not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/logotipos\/syscom_towers.png\" alt=\"Logo SYSCOM TOWERS\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eHighlighted Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under \u003cstrong style=\"color: #d10404;\"\u003e\u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e\u003c\/strong\u003e standards.\n\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eHigh Elevation \/ Low cost.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e100% Section-by-Section Assembly Inspection.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eHot-dip galvanized in accordance with \u003cstrong style=\"color: #d10404;\"\u003e\u003cstrong\u003eNMX-H-004-SCFI-2008\u003c\/strong\u003e.\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px; text-align: left;\"\u003eIdeal for coastal areas with high humidity or industrial zones.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003ePhysical Characteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eMaximum Axial Load: 350 Kg.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eHeight: 21 meters (7 sections).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eWind resistance: 200 km\/h.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAnticorrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eApplication: Outdoor (Humid zones).\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eIncludes the following components:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cdiv style=\"border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eKit Components\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 7 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/STZ-35G-SYSCOM-TOWERS-31577.html\" target=\"_blank\" rel=\"noopener\"\u003eSTZ35G\u003c\/a\u003e - Tower section with 35 cm face width.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SCZ-35-PG-SYSCOM-TOWERS-169014.html\" target=\"_blank\" rel=\"noopener\"\u003eSCZ35PG\u003c\/a\u003e - 35 cm tower top with set screw for lightning rod.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SBZ-35G-SYSCOM-TOWERS-29193.html\" target=\"_blank\" rel=\"noopener\"\u003eSBZ35G\u003c\/a\u003e - 35 cm tower base.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SAB-45G-SYSCOM-TOWERS-29014.html\" target=\"_blank\" rel=\"noopener\"\u003eSAB45G\u003c\/a\u003e - Anchor for 35\/45 tower base.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 3 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SJB-35G-SYSCOM-TOWERS-29955.html\" target=\"_blank\" rel=\"noopener\"\u003eSJB35G\u003c\/a\u003e - Guy wire attachment flange.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 3 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SAZ-45G-SYSCOM-TOWERS-29086.html\" target=\"_blank\" rel=\"noopener\"\u003eSAZ45G\u003c\/a\u003e - Floor anchor for guy wire.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 18 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-14-HDG-SYSCOM-TOWERS-199560.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-14-HDG\u003c\/a\u003e - Thimble for guy wire.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 54 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/NUDO-316-FJG-SYSCOM-TOWERS-199580.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-316-FJG\u003c\/a\u003e - 3\/16' cable clamp.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp style=\"margin: 20px 0 10px 0;\"\u003e\u003cstrong style=\"color: #c0392b;\"\u003eGuy wire not included.\u003c\/strong\u003e 215 meters of 3\/16' guy wire (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/S-RET-474-CAM-CAMESA-151128.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-474-CAM\u003c\/a\u003e or \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SRET-316-DA-SYSCOM-TOWERS-208681.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-316-DA\u003c\/a\u003e) or larger diameters are recommended.\u003c\/p\u003e\n\n\u003cp style=\"margin: 10px 0;\"\u003e\u003cstrong style=\"color: #c0392b;\"\u003eTurnbuckles not included.\u003c\/strong\u003e 9 turnbuckles of 5\/8' x 9' are recommended (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/TEN5\/8X9OGJ-SYSCOM-TOWERS-209938.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN5\/8X9OGJ\u003c\/a\u003e or \u003ca href=\"https:\/\/www.syscom.mx\/producto\/TEN5\/8X9OQJ-SYSCOM-TOWERS-209835.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN5\/8X9OQJ\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003cdiv style=\"margin: 20px 0; padding: 15px; border-left: 4px solid #e67e22; background-color: rgba(255, 255, 255, 0.03);\"\u003e\u003cem\u003e\u003cstrong style=\"color: #000000;\"\u003e**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional adaptation is the responsibility of the installer.**\u003c\/strong\u003e\u003c\/em\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eComplementary accessories \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003ch4 style=\"font-size: 18px; margin-top: 15px; margin-bottom: 10px; color: #c0392b; font-weight: 600;\"\u003e\u003cspan style=\"font-size: 14px; color: inherit; font-weight: bold; line-height: 18px;\"\u003eSignaling\/Lighting System \u003cspan style=\"font-size: 10px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e:\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cdiv style=\"border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column; margin-bottom: 20px;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSignaling Components\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/EI-GSL-SE-EPCOM-INDUSTRIAL-155623.html\" target=\"_blank\" rel=\"noopener\"\u003eEIGSLSE\u003c\/a\u003e - Autonomous LED strobe with photocell, solar panel, and battery. Type L810.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/HLU-3R2-EPCOM-INDUSTRIAL-196712.html\" target=\"_blank\" rel=\"noopener\"\u003eHLU3R2\u003c\/a\u003e - Mount for EIGSLSE obstruction lamp.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp style=\"margin: 20px 0 10px 0;\"\u003e\u003cem\u003e\u003cspan style=\"font-size: 12px;\"\u003e*Signaling regulations state that the tower must be painted in 7 equal-sized bands; 4 bands in reddish-orange and 3 in white.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch4 style=\"font-size: 18px; margin-top: 15px; margin-bottom: 10px; color: #c0392b; font-weight: 600;\"\u003e\u003cspan style=\"font-size: 14px; color: inherit; font-weight: bold; line-height: 18px;\"\u003eLifeline system \u003cspan style=\"font-size: 10px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e:\u003c\/span\u003e\u003c\/h4\u003e\n\n\u003cdiv style=\"border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column; margin-bottom: 20px;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eLifeline Components\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=SHE-LV-SYSCOM-TOWERS-29815\u0026amp;autodetect=shelv\"\u003eSHE-LV\u003c\/a\u003e - Pair of mounting brackets.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=S-GULV-SYSCOM-TOWERS-29794\u0026amp;autodetect=sgul\"\u003eS-GULV\u003c\/a\u003e - Cable guide.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 24 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SRET-338-SYSCOM-31077.html\"\u003eSRET-338CAM\u003c\/a\u003e - 3\/8' cable.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 6 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/NUDO-38-FJG-SYSCOM-TOWERS-199587.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-38FJG\u003c\/a\u003e - 3\/8' forged cable clamp.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-38-HDG-SYSCOM-TOWERS-199562.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-38-HDG\u003c\/a\u003e - 3\/8' thimble.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=TRY-ACC-SLIDER-Trylon-161793\u0026amp;autodetect=carro\"\u003eTRY-ACC-SLIDER\u003c\/a\u003e - (Optional) Safety slider for installer.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=SYS-USA7B-URREA-174988\u0026amp;autodetect=sysusa\"\u003eSYS-USA7B\u003c\/a\u003e - (Optional) Suspension harness.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp style=\"margin: 20px 0 10px 0;\"\u003e\u003cem\u003e*NOM-009 mandates the use of systems that arrest accidental falls on a structure.\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eRecommended Physical Grounding System for Tower and Mounted Equipment \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cdiv style=\"border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column; margin-bottom: 20px;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eGrounding Components\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\"\u003eTG45AB\u003c\/a\u003e - 45 A grounding electrode with electrode, filter, and H2Ohm compound.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\"\u003eS610\u003c\/a\u003e - Plastic inspection box.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 3 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\"\u003eTGCR11\u003c\/a\u003e - Eye connector.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\"\u003eTGAB18\u003c\/a\u003e - Rod connector.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGBUSG10-TOTAL-GROUND-75914.html\"\u003eTGBUSG10\u003c\/a\u003e - 1000A capacity busbar with insulators (no enclosure).\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp style=\"margin: 20px 0;\"\u003e\u003cem\u003e*Using 4 AWG jacketed copper wire (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SLY-287-GRN-INDIANA-176933.html\"\u003eSLY-287-GRN\u003c\/a\u003e) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SL-Y-291-GRN-100-INDIANA-87721.html\"\u003eSLY-291-GRN\u003c\/a\u003e) can be used.\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eRecommended Basic Lightning Rod System for Tower \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cdiv style=\"border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column; margin-bottom: 20px;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eLightning Rod Components\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGTDPC-TOTAL-GROUND-76020.html\"\u003eTGTDPC\u003c\/a\u003e - Lightning rod tip with aluminum mast (MASTIL1.2).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\"\u003eTG45AB\u003c\/a\u003e - 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\"\u003eS610\u003c\/a\u003e - Small plastic inspection box.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/ANTIOX-TOTAL-GROUND-75931.html\"\u003eANTIOX\u003c\/a\u003e - Spray for terminal protection.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 3 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\"\u003eTGCR11\u003c\/a\u003e - Eye connector.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\"\u003eTGAB18\u003c\/a\u003e - Rod connector.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 14 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/TG-AC-114-TOTAL-GROUND-85849.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAC114\u003c\/a\u003e - Tower insulator.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp style=\"margin: 20px 0;\"\u003e\u003cem\u003e*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin: 10px 0;\"\u003e\u003cem\u003e*2\/0 gauge copper wire is recommended for the integration (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SLY-346-BLK-INDIANA-176872.html\"\u003eSLY-346-BLK\u003c\/a\u003e). Considering an electrode installation at most 3 meters from the tower, approx. 8 meters are used.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin: 20px 0;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2019\/03\/27\/2ed55\/01REV02-DIPOLO%20CORONA%20Y%20EQUIPO%20EN%20TORRE.pdf\"\u003eDIAGRAM\u003c\/a\u003e\u003c\/strong\u003e for Physical Ground + Lightning Rod connection\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cstrong\u003eRecommendations:\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEnsure installation is carried out by a trained professional.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan for checking guy tension and adjusting hardware.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eA stress study must be conducted when an eccentric load is placed on the tower. This can cause excessive torsion and bending, leading to structural failure.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in reddish-orange and white, in 7 equal-height bands starting and ending in reddish-orange (SYSCOM does not perform tower painting).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eIt is recommended to illuminate the tower, at least at the top, with a red lamp.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRepresentative Diagram: Guy Wire Installation Version 2.0\u003c\/h3\u003e\n\n\u003cdiv style=\"border: 1px solid rgba(150,150,150,0.3); border-radius: 8px; overflow: hidden; margin: 20px 0;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: none;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" alt=\"Guy Wire Installation Diagram Version 2.0\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInstallation Images\u003c\/h3\u003e\n\n\u003cdiv style=\"border: 1px solid rgba(150,150,150,0.3); border-radius: 8px; overflow: hidden; margin: 20px 0;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: none;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/ARRIOSTRADAS\/TORRES%20IMAGEN.png\" alt=\"Installation Images\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828325240991,"sku":"KTZ-35G-021","price":41399.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/KTZ35G021-p.png?v=1783708291","url":"https:\/\/store.glaretum.com\/en\/products\/kit-de-torre-arriostrada-de-piso-de-21-m-altura-con-tramo-stz35g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","provider":"Glaretum","version":"1.0","type":"link"}