{"product_id":"kit-de-torre-arriostrada-de-piso-de-30-m-altura-con-tramo-stz30-galvanizado-electrolitico-no-incluye-retenida","title":"30m Guyed Tower Kit for Ground Installation with STZ30 Electro-Galvanized Section (Guy wires not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/logotipos\/syscom_towers.png\" alt=\"SYSCOM TOWERS Logo\"\u003e \u003c\/h3\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under ISO 9001:2015 standards.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHigh elevation \/ Low cost.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e100% section-by-section assembly inspection.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eElectrolytic galvanization according to ASTM B-633 standards.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIdeal for dry, corrosion-free areas.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePhysical Characteristics\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaximum Axial Load:\u003c\/strong\u003e 200 kg.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 30 meters (10 sections).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eWind Resistance:\u003c\/strong\u003e 200 km\/hr.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAnti-corrosion protection:\u003c\/strong\u003e Electrolytic Galvanization (ASTM B-633).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Outdoor (Desert or low-humidity areas).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eIncludes the following components:\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e10 units:\u003c\/strong\u003e STZ30 - 30 cm face width tower section\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e SCZ30P - 30 cm tower top cap with set screw for lightning rod\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e SBA30 - Base for 30 cm tower\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e SAB30 - Tower base anchor\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e5 units:\u003c\/strong\u003e SJB30 - Guy wire clamp flange\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e3 units:\u003c\/strong\u003e SAP02 - Floor anchor for guy wire\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e30 units:\u003c\/strong\u003e CUELLO-14-HDG - Thimble for guy cable\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e90 units:\u003c\/strong\u003e NUDO-316-FJG - 3\/16' wire rope clip\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003cp style=\"color: inherit; font-weight: bold; margin: 0 0 10px;\"\u003e\u003cstrong\u003eGuy cable not included.\u003c\/strong\u003e 480 meters of 1\/8' guy wire (SRET-318-CAM) or larger diameters are recommended.\u003c\/p\u003e \u003cp style=\"color: inherit; margin: 0 0 10px;\"\u003e\u003cstrong\u003eTurnbuckles not included.\u003c\/strong\u003e 15 1\/2' x 6' turnbuckles (TEN1\/2X6OGJ or TEN1\/2X6OQJ) are recommended.\u003c\/p\u003e \u003cp style=\"color: inherit; font-size: 12px; margin: 0;\"\u003e \u003cem\u003e**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy anchors is considered a forfeiture of the equipment warranty, and any additional modifications are the responsibility of the installer.**\u003c\/em\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eComplementary accessories (Not included)\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003ch4 style=\"margin-top: 0; margin-bottom: 15px; font-size: 16px; color: inherit; opacity: 0.9;\"\u003eSignaling\/Lighting System (Not included)\u003c\/h4\u003e \u003cul style=\"padding-left: 20px; margin: 0 0 15px; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e2 units:\u003c\/strong\u003e EIGSLSE - Autonomous LED strobe with photocell, solar panel, and battery. Type L810\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e2 units:\u003c\/strong\u003e HLU3R2 - Mount for EIGSLSE obstruction light\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"margin: 0 0 10px; font-size: 12px;\"\u003e *Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 in orange-red and 3 in white. \u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eLifeline system (Not included)\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e SHE-LV - Pair of mounting brackets\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e S-GULV - Line guide\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e33 units:\u003c\/strong\u003e SRET-338CAM - 3\/8' cable\u003c\/li\u003e \u003cli style=\"margin-bottom: 6 units:\u0026lt;\/strong\u0026gt; NUDO-38FJG - 3\/8' forged wire rope clip\u0026lt;\/li\u0026gt; \u0026lt;li style=\" margin-bottom:\u003e\n\n\u003cstrong\u003e2 units:\u003c\/strong\u003e CUELLO-38-HDG - 3\/8' thimble\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e TRY-ACC-SLIDER - Safety Slider for installer (Optional)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e SYS-USA7B - Suspension harness (Optional)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"margin: 15px 0 0; font-size: 12px;\"\u003e *NOM-009 mandates the use of systems that arrest accidental falls on a structure. \u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eNew! Lightning Rod Kit + Grounding with cable (Not included)\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cp style=\"margin: 0 0 10px;\"\u003e \u003cstrong\u003eKLP-TZ30-PRO\u003c\/strong\u003e - Everything included! Ideal for 30m towers with corona dipole, wiring, and electrodes. \u003c\/p\u003e \u003cp style=\"margin: 0 0 10px; font-size: 12px;\"\u003e Alternatively, you may individually quote the following Grounding or Lightning Rod components: \u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eRecommended Grounding System for Tower and equipment mounted on it (Not included)\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e TG45AB - 45A grounding electrode with electrode, filter, and H2Ohm compound\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e S610 - Plastic inspection well\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e3 units:\u003c\/strong\u003e TGCR11 - Eye connector\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e2 units:\u003c\/strong\u003e TGAB18 - Rod connector\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e TGBUSG10 - 1000A capacity ground bus bar with insulators (without cabinet)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"margin: 15px 0 0; font-size: 12px;\"\u003e *Use of 4 AWG coated copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. For tower equipment, 6 AWG (SLY-291-GRN) can be used. \u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eRecommended Basic Lightning Rod System for Tower (Not included)\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e TGTDPC - Lightning rod tip with aluminum mast (MASTIL1.2)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e TG45AB - 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e S610 - Small plastic inspection well\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e1 unit:\u003c\/strong\u003e ANTIOX - Spray for terminal protection\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e3 units:\u003c\/strong\u003e TGCR11 - Eye connector\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e2 units:\u003c\/strong\u003e TGAB18 - Rod connector\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e20 units:\u003c\/strong\u003e TGAC - Tower insulator\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"margin: 15px 0 0; font-size: 12px;\"\u003e *The dipole tip offers a 72° protection cone below the coil. Recommended for low lightning incidence areas. \u003c\/p\u003e \u003cp style=\"margin: 15px 0 0; font-size: 12px;\"\u003e *2\/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering a maximum electrode installation distance of 3 meters from the tower, approx. 8 meters are used. \u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003cp style=\"margin: 0 0 10px; color: inherit; font-size: 14px;\"\u003e See the Grounding + Lightning Rod connection diagram in the following \u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2019\/03\/27\/2ed55\/01REV02-DIPOLO%20CORONA%20Y%20EQUIPO%20EN%20TORRE.pdf\" style=\"color: currentColor; text-decoration: underline;\" target=\"_blank\" rel=\"noopener\"\u003eDIAGRAM\u003c\/a\u003e. \u003c\/p\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRecommendations\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEnsure installation is performed by a trained professional.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan to check guy tensions and tighten hardware.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA structural stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in orange-red and white, in 7 equal-height bands starting and ending with orange-red (SYSCOM does not perform tower painting).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIt is recommended to light the tower at least at the tip with a red lamp.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRepresentative Diagram: Guy wire installation Version 2.0\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" alt=\"Guy wire installation diagram Version 2.0\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInstallation images\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/ARRIOSTRADAS\/TORRES%20IMAGEN.png\" alt=\"Tower installation image\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828320325791,"sku":"KTZ-30E-030","price":31299.0,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/KTZ30E030-p.png?v=1783708079","url":"https:\/\/store.glaretum.com\/en\/products\/kit-de-torre-arriostrada-de-piso-de-30-m-altura-con-tramo-stz30-galvanizado-electrolitico-no-incluye-retenida","provider":"Glaretum","version":"1.0","type":"link"}