{"product_id":"kit-de-torre-arriostrada-de-piso-de-30-m-con-tramo-stz30g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","title":"30m Ground-Based Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wires not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003c!-- Sección de logo --\u003e \u003cdiv style=\"display: flex; justify-content: center; margin-bottom: 30px;\"\u003e \u003cimg style=\"width: 100%; max-width: 300px; height: auto;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/logotipos\/syscom_towers.png\" alt=\"Logo SYSCOM TOWERS\"\u003e \u003c\/div\u003e \u003c!-- Sección de características destacadas --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under \u003cstrong style=\"color: #d10404;\"\u003eISO 9001:2015\u003c\/strong\u003e standards.\n\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHigh Elevation \/ Low Cost.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e100% section-by-section assembly inspection.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHot-dip galvanized in accordance with \u003cstrong style=\"color: #d10404;\"\u003eNMX-H-004-SCFI-2008\u003c\/strong\u003e.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIdeal for high-humidity coastal zones or industrial areas.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Sección de características físicas --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePhysical Characteristics\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaximum Axial Load:\u003c\/strong\u003e 200 kg.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 30 meters (10 sections).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eWind Resistance:\u003c\/strong\u003e 200 km\/h.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCorrosion Protection:\u003c\/strong\u003e Hot-dip galvanized (NMX-H-004-SCFI-2008).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Outdoor (Humid Zones).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Sección de componentes incluidos --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eIncludes the following components\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px;\"\u003e \u003cthead style=\"background-color: rgba(150, 150, 150, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e10\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/STZ-30G-SYSCOM-TOWERS-31574.html\" target=\"_blank\" rel=\"noopener\"\u003eSTZ30G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eTower section, 30 cm face width.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SCZ-30-PG-SYSCOM-TOWERS-169012.html\" target=\"_blank\" rel=\"noopener\"\u003eSCZ30PG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e30 cm tower top with lightning rod clamp.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SBA-30G-SYSCOM-TOWERS-29104.html\" target=\"_blank\" rel=\"noopener\"\u003eSBA30G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e30 cm tower base.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SAB-30G-SYSCOM-TOWERS-29012.html\" target=\"_blank\" rel=\"noopener\"\u003eSAB30G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eTower base anchor.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e5\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SJB-30G-SYSCOM-TOWERS-29952.html\" target=\"_blank\" rel=\"noopener\"\u003eSJB30G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eGuy wire support bracket.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SAP-02G-SYSCOM-TOWERS-29055.html\" target=\"_blank\" rel=\"noopener\"\u003eSAP02G\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eGround anchor for guy wire.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e30\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-14-HDG-SYSCOM-TOWERS-199560.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-14-HDG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eGuy wire thimble.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e90\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-316-FJG-SYSCOM-TOWERS-199580.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-316-FJG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/16\" wire rope clip.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 20px; color: #c0392b;\"\u003e\u003cstrong\u003eGuy wire not included.\u003c\/strong\u003e 480 meters of 1\/8\" guy wire (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SRET318CAM-CAMESA-151126.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-318-CAM\u003c\/a\u003e) or larger diameters are recommended.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de no incluye tensores --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003cp style=\"color: #c0392b; margin-bottom: 5px;\"\u003e\u003cstrong\u003eTurnbuckles not included\u003c\/strong\u003e. 15 turnbuckles (1\/2\" x 6\") are recommended (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OGJ-SYSCOM-TOWERS-199554.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OGJ\u003c\/a\u003e or \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OQJ-SYSCOM-TOWERS-199557.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OQJ\u003c\/a\u003e).\u003c\/p\u003e \u003cp style=\"margin: 15px 0; font-size: 14px;\"\u003e\u003cem\u003e**Failure to use installation accessories such as brackets, tower base, tower anchor, or guy wire anchors will be considered a voidance of the equipment warranty, and any additional modifications remain the responsibility of the installer.**\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de accesorios complementarios --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eComplementary accessories \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/h3\u003e \u003ch4 style=\"font-size: 18px; color: inherit; opacity: 0.8; margin-top: 15px;\"\u003eSignaling\/Lighting System \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/h4\u003e \u003c!-- Tabla de señalización e iluminación --\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px;\"\u003e \u003cthead style=\"background-color: rgba(150, 150, 150, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/EI-GSL-SE-EPCOM-INDUSTRIAL-155623.html\" target=\"_blank\" rel=\"noopener\"\u003eEIGSLSE\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eSelf-contained LED strobe light with photocell, solar panel, and battery. Type L810.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/HLU-3R2-EPCOM-INDUSTRIAL-196712.html\" target=\"_blank\" rel=\"noopener\"\u003eHLU3R2\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eMounting bracket for EIGSLSE obstruction light\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 15px 0;\"\u003e\u003cem\u003e* Signaling standards dictate that the tower must be painted in 7 stripes of equal size; 4 orange-red stripes and 3 white stripes.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de sistema de línea de vida --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 18px; color: inherit; opacity: 0.8; margin-top: 0; margin-bottom: 15px;\"\u003eLifeline system \u003cspan style=\"font-size: 12px; color: #7e8c8d;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e \u003cthead style=\"background-color: rgba(150, 150, 150, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SHE-LV-SYSCOM-TOWERS-29815.html\" target=\"_blank\" rel=\"noopener\"\u003eSHE-LV\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003ePair of mounting brackets\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/S-GULV-SYSCOM-TOWERS-29794.html\" target=\"_blank\" rel=\"noopener\"\u003eS-GULV\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eLine guide\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e33\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SRET318CAM-CAMESA-151126.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-338CAM\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8\" cable\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e6\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-38-FJG-SYSCOM-TOWERS-199587.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-38FJG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8\" forged wire rope clip\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-38-HDG-SYSCOM-TOWERS-199562.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-38-HDG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8\" thimble\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/TRY-ACC-SLIDER2-Trylon-192532.html\" target=\"_blank\" rel=\"noopener\"\u003eTRY-ACC-SLIDER\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e(Optional) Safety slider for installer.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SYS-USA7B-URREA-174988.html\" target=\"_blank\" rel=\"noopener\"\u003eSYS-USA7B\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e(Optional) Suspension harness.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 15px 0;\"\u003e\u003cem\u003e* NOM-009 mandates the use of systems that stop accidental falls on a structure.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de pararrayo --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 18px; color: #e74c3c; margin-top: 0; margin-bottom: 15px;\"\u003e\n\n\u003cspan style=\"color: #e74c3c;\"\u003eNew!\u003c\/span\u003e Lightning Rod Kit + Grounding with cable. LINKEDPRO brand \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/h3\u003e \u003cp style=\"margin: 10px 0;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/KLP-TZ30-PRO-LINKEDPRO-BY-EPCOM-192191.html\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eKLP-TZ30-PRO\u003c\/strong\u003e\u003c\/a\u003e - All included! Ideal for 30m towers with crown dipole, wiring, and electrodes.\u003c\/p\u003e \u003cp style=\"margin: 10px 0;\"\u003e\u003cem\u003eAlternatively, you can quote the following individual grounding or lightning rod components:\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de tierra física --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 18px; color: inherit; opacity: 0.8; margin-top: 0; margin-bottom: 15px;\"\u003eGrounding system recommended for tower and mounted equipment \u003cspan style=\"font-size: 12px; color: #7e8c8d;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e \u003cthead style=\"background-color: rgba(150, 150, 150, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e45 A grounding electrode with electrode, filter, and H2Ohm compound\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003ePlastic junction box.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\" target=\"_blank\" rel=\"noopener\"\u003eTGCR11\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eEye connector\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eGround rod connector\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGBUSG10-TOTAL-GROUND-75914.html\" target=\"_blank\" rel=\"noopener\"\u003eTGBUSG10\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e1000A capacity busbar with insulators (without enclosure)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 15px 0;\"\u003e\u003cem\u003e* The use of 4 AWG coated copper cable (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SLY-287-GRN-INDIANA-176933.html\"\u003eSLY-287-GRN\u003c\/a\u003e) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SL-Y-291-GRN-100-INDIANA-87721.html\"\u003eSLY-291-GRN\u003c\/a\u003e) can be used.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de pararrayos --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 18px; color: inherit; opacity: 0.8; margin-top: 0; margin-bottom: 15px;\"\u003eBasic Lightning Rod System recommended for Tower \u003cspan style=\"font-size: 12px; color: #7e8c8d;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e \u003cthead style=\"background-color: rgba(150, 150, 150, 0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eQuantity\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGTDPC-TOTAL-GROUND-76020.html\" target=\"_blank\" rel=\"noopener\"\u003eTGTDPC\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eLightning rod tip with aluminum mast (MASTIL1.2)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003e45 Amp electrode. With a bag of impedance-improving compound (H2OHM), compass, and level.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eSmall plastic inspection box.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/ANTIOX-TOTAL-GROUND-75931.html\" target=\"_blank\" rel=\"noopener\"\u003eANTIOX\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eSpray for terminal protection.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\" target=\"_blank\" rel=\"noopener\"\u003eTGCR11\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eEye connector.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eRod connector.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e20\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAC-TOTAL-GROUND-76016.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAC\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 10px; border: 1px solid rgba(150,150,150,0.3);\"\u003eTower insulator.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 15px 0;\"\u003e\u003cem\u003e*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.\u003c\/em\u003e\u003c\/p\u003e \u003cp style=\"margin: 15px 0;\"\u003e\u003cem\u003eA 2\/0 gauge copper cable is recommended for the integration (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SLY-346-BLK-INDIANA-176872.html\"\u003eSLY-346-BLK\u003c\/a\u003e). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.\u003c\/em\u003e\u003c\/p\u003e \u003cp style=\"margin: 15px 0;\"\u003e\u003cem\u003eSee the Grounding + Lightning Rod connection diagram in the following \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2019\/03\/27\/2ed55\/01REV02-DIPOLO%20CORONA%20Y%20EQUIPO%20EN%20TORRE.pdf\"\u003eDIAGRAM\u003c\/a\u003e.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sección de recomendaciones --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRecommendations\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEnsure the installation is performed by a trained professional.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan for checking guy wire tension and adjusting hardware.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA stress study must be performed when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, resulting in structural failure.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not provide tower painting services).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIt is recommended to illuminate the tower at least at the top with a red lamp.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Imagen de instalación --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 18px; color: inherit; opacity: 0.8; margin-top: 0; margin-bottom: 15px;\"\u003eRepresentative Diagram: Guy Wire Installation Version 2.0\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" alt=\"Guy wire installation diagram version 2.0\"\u003e \u003c\/div\u003e \u003c!-- Imágenes adicionales --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 18px; color: inherit; opacity: 0.8; margin-top: 0; margin-bottom: 15px;\"\u003eInstallation Images\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/ARRIOSTRADAS\/TORRES%20IMAGEN.png\" alt=\"Tower installation images\"\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828317081759,"sku":"KTZ-30G-030","price":38399.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/KTZ30G030-p.png?v=1783707914","url":"https:\/\/store.glaretum.com\/en\/products\/kit-de-torre-arriostrada-de-piso-de-30-m-con-tramo-stz30g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","provider":"Glaretum","version":"1.0","type":"link"}