{"product_id":"kit-de-torre-arriostrada-de-piso-de-39-m-altura-con-tramo-stz45g-galvanizado-por-inmersion-en-caliente-no-incluye-retenida","title":"39 m Height Guyed Floor Tower Kit with Hot-Dip Galvanized STZ45G Section. (Guy wires not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/logotipos\/syscom_towers.png\" alt=\"SYSCOM TOWERS Logo\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eProduct manufactured under \u003cstrong style=\"color: #d10404;\"\u003eISO 9001:2015\u003c\/strong\u003e standards.\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eHigh elevation \/ Low cost.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e100% inspection of section-by-section assembly.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\u003cspan style=\"box-sizing: border-box;\"\u003eHot-dip galvanized in accordance with \u003cstrong style=\"color: #d10404;\"\u003eNMX-H-004-SCFI-2008\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eIdeal for high-humidity coastal zones or industrial areas.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003ePhysical Specifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eMaximum Axial Load: 500 kg.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eHeight: 39 meters (13 sections).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eWind resistance: 200 km\/hr.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAnti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eApplication: Outdoor (Humid zones).\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eIncludes the following components:\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e13 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/STZ-45G-SYSCOM-TOWERS-31580.html\" target=\"_blank\" rel=\"noopener\"\u003eSTZ45G\u003c\/a\u003e: 45 cm face width tower section.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SCZ-45G-SYSCOM-TOWERS-29420.html\" target=\"_blank\" rel=\"noopener\"\u003eSCZ45G\u003c\/a\u003e: 45 cm tower top cap with lightning rod clamp.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SBZ-45G-SYSCOM-TOWERS-29196.html\" target=\"_blank\" rel=\"noopener\"\u003eSBZ45G\u003c\/a\u003e: Base for 45 cm tower.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SAB-45G-SYSCOM-TOWERS-29014.html\" target=\"_blank\" rel=\"noopener\"\u003eSAB45G\u003c\/a\u003e: Anchor for 35\/45 tower base.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e5 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SJB-45G-SYSCOM-TOWERS-29958.html\" target=\"_blank\" rel=\"noopener\"\u003eSJB45G\u003c\/a\u003e: Guy wire clamp.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e3 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SAZ-45G-SYSCOM-TOWERS-29086.html\" target=\"_blank\" rel=\"noopener\"\u003eSAZ45G\u003c\/a\u003e: Floor anchor for guy wire.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e30 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-14-HDG-SYSCOM-TOWERS-199560.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-14-HDG\u003c\/a\u003e: Thimble for guy wire.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e90 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/NUDO-14-FJG-SYSCOM-TOWERS-199581.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-14-FJG\u003c\/a\u003e: 1\/4' wire rope clip.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eRecommended accessories\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\n\u003cp style=\"margin: 0 0 10px 0;\"\u003e\u003cstrong style=\"color: #c0392b;\"\u003eGuy wire is not included.\u003c\/strong\u003e We recommend 600 meters of 1\/4' guy wire (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/S-RET-635CAM-CAMESA-151130.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-635-CAM\u003c\/a\u003e) or larger diameters.\u003c\/p\u003e\n\n\u003cp style=\"margin: 0 0 10px 0;\"\u003e\u003cstrong style=\"color: #c0392b;\"\u003eTurnbuckles are not included\u003c\/strong\u003e. We recommend 15 turnbuckles of 5\/8' x 9' (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/TEN5\/8X9OGJ-SYSCOM-TOWERS-209938.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN5\/8X9OGJ\u003c\/a\u003e or \u003ca href=\"https:\/\/www.syscom.mx\/producto\/TEN5\/8X9OQJ-SYSCOM-TOWERS-209835.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN5\/8X9OQJ\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003cp style=\"margin: 0;\"\u003e\u003cem\u003e*Failure to use installation accessories such as clamps, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the responsibility of the installer.\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\n\n\u003cspan style=\"color: #c0392b;\"\u003eSignaling\/Lighting System \u003c\/span\u003e\u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\n\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e2 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/EI-GSL-SE-EPCOM-INDUSTRIAL-155623.html\" target=\"_blank\" rel=\"noopener\"\u003eEIGSLSE\u003c\/a\u003e: Autonomous LED strobe with photocell, solar panel, and battery. Type L810.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e2 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/HLU-3R2-EPCOM-INDUSTRIAL-196712.html\" target=\"_blank\" rel=\"noopener\"\u003eHLU3R2\u003c\/a\u003e: Mounting for EIGSLSE obstruction light.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp style=\"margin: 15px 0 0 0;\"\u003e\u003cem\u003e*Signaling standards dictate that the tower must be painted in 7 alternating bands of equal size; 4 orange-red bands and 3 white bands.\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\n\n\u003cspan style=\"color: #c0392b;\"\u003eLifeline System\u003c\/span\u003e \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\n\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=SHE-LV-SYSCOM-TOWERS-29815\u0026amp;autodetect=shelv\" target=\"_blank\" rel=\"noopener\"\u003eSHE-LV\u003c\/a\u003e: Pair of mounting brackets.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e2 - \u003ca href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=S-GULV-SYSCOM-TOWERS-29794\u0026amp;autodetect=sgul\" target=\"_blank\" rel=\"noopener\"\u003eS-GULV\u003c\/a\u003e: Line guide.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e42 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SRET318CAM-CAMESA-151126.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-338CAM\u003c\/a\u003e: 3\/8' cable.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e6 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/NUDO-38-FJG-SYSCOM-TOWERS-199587.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-38FJG\u003c\/a\u003e: 3\/8' forged wire rope clip.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e2 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-38-HDG-SYSCOM-TOWERS-199562.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-38-HDG\u003c\/a\u003e: 3\/8' thimble.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=TRY-ACC-SLIDER-Trylon-161793\u0026amp;autodetect=carro\" target=\"_blank\" rel=\"noopener\"\u003eTRY-ACC-SLIDER\u003c\/a\u003e: (Optional) Safety Slider for installer.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=SYS-USA7B-URREA-174988\u0026amp;autodetect=sysusa\" target=\"_blank\" rel=\"noopener\"\u003eSYS-USA7B\u003c\/a\u003e: (Optional) Full-body harness.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp style=\"margin: 15px 0 0 0;\"\u003e\u003cem\u003e*NOM-009 requires the use of systems that arrest accidental falls from a structure.\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\n\n\u003cspan style=\"color: #c0392b;\"\u003eRecommended Grounding System for Tower and Mounted Equipment\u003c\/span\u003e \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\n\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e: 45A grounding electrode with filter and H2Ohm compound.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e: Plastic inspection well.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 3 - \u0026lt;a href=\" http: target=\"_blank\" rel=\"noopener\"\u003eTGCR11: Eye connector.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e2 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e: Rod connector.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGBUSG10-TOTAL-GROUND-75914.html\" target=\"_blank\" rel=\"noopener\"\u003eTGBUSG10\u003c\/a\u003e: 1000A capacity grounding busbar (no cabinet).\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp style=\"margin: 15px 0 0 0;\"\u003e\u003cem\u003e*We recommend 4 AWG jacketed copper wire (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SLY-287-GRN-INDIANA-176933.html\" target=\"_blank\" rel=\"noopener\"\u003eSLY-287-GRN\u003c\/a\u003e) for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SL-Y-291-GRN-100-INDIANA-87721.html\" target=\"_blank\" rel=\"noopener\"\u003eSLY-291-GRN\u003c\/a\u003e) can be used.\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\n\n\u003cspan style=\"color: #c0392b;\"\u003eRecommended Basic Lightning Protection System for Tower\u003c\/span\u003e \u003cspan style=\"font-size: 12px; color: #95a5a6;\"\u003e(Not included)\u003c\/span\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\n\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGTDPC-TOTAL-GROUND-76020.html\" target=\"_blank\" rel=\"noopener\"\u003eTGTDPC\u003c\/a\u003e: Lightning rod tip with aluminum mast (MASTIL1.2).\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e: 45 Amp electrode with impedance-improving compound (H2OHM), compass, and level.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e: Small plastic inspection well.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e1 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/ANTIOX-TOTAL-GROUND-75931.html\" target=\"_blank\" rel=\"noopener\"\u003eANTIOX\u003c\/a\u003e: Protective spray for terminals.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e3 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\" target=\"_blank\" rel=\"noopener\"\u003eTGCR11\u003c\/a\u003e: Eye connector.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e2 - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e: Rod connector.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e26 - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/TG-AC-114-TOTAL-GROUND-85849.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAC114\u003c\/a\u003e: Tower insulator.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp style=\"margin: 15px 0 0 0;\"\u003e\u003cem\u003e*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.\u003cbr\u003e*We recommend 2\/0 gauge copper wire for integration (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SLY-346-BLK-INDIANA-176872.html\" target=\"_blank\" rel=\"noopener\"\u003eSLY-346-BLK\u003c\/a\u003e). Assuming the electrode is installed at a maximum of 3 meters from the tower, approx. 8 meters are used.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin: 15px 0 0 0;\"\u003e\u003cstrong\u003eView Grounding + Lightning Protection connection diagram:\u003c\/strong\u003e \u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2019\/03\/27\/2ed55\/01REV02-DIPOLO%20CORONA%20Y%20EQUIPO%20EN%20TORRE.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDIAGRAM\u003c\/a\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cstrong\u003eRecommendations:\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEnsure installation is performed by a trained professional.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEstablish a maintenance plan for checking guy wire tension and hardware tightening.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eA stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive twisting and bending, leading to structural failure.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted orange-red and white, in 7 bands of equal height, starting and ending with orange-red (SYSCOM does not perform painting).\u003c\/li\u003e\n\n\u003cli\u003eIt is recommended to illuminate the tower at the top with at least one red lamp.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRepresentative Diagram: Guy Wire Installation Version 2.0\u003c\/h3\u003e\n\n\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" alt=\"Guy wire installation diagram\"\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; margin-bottom: 15px; color: inherit; opacity: 0.8;\"\u003eInstallation Images\u003c\/h3\u003e\n\n\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/ARRIOSTRADAS\/TORRES%20IMAGEN.png\" alt=\"Guyed Tower Installation\"\u003e\n\n\u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828345131167,"sku":"KTZ-45G-039","price":85599.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/KTZ45G039-p.png?v=1783709250","url":"https:\/\/store.glaretum.com\/en\/products\/kit-de-torre-arriostrada-de-piso-de-39-m-altura-con-tramo-stz45g-galvanizado-por-inmersion-en-caliente-no-incluye-retenida","provider":"Glaretum","version":"1.0","type":"link"}