{"product_id":"kit-de-torre-arriostrada-de-techo-de-12-m-con-tramo-stz30-galvanizado-electrolitico-no-incluye-retenida","title":"12m Roof Guyed Tower Kit with STZ30 Electro-Galvanized Section (Guy wire not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 30px;\"\u003e \u003c!-- Logo --\u003e \u003cdiv style=\"width: 100%; display: flex; justify-content: center; align-items: center;\"\u003e \u003cimg style=\"width: 100%; max-width: 300px; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/logotipos\/syscom_towers.png\" alt=\"SYSCOM TOWERS Logo\"\u003e \u003c\/div\u003e \u003c!-- Características Destacadas --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit; list-style: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under ISO 9001:2015 standards.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHigh elevation \/ Low cost.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e100% inspection of section-by-section assembly.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eElectrolytic galvanization in accordance with ASTM B-633 standards.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIdeal for dry areas free of corrosion.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Características Físicas --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePhysical Characteristics\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit; list-style: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMaximum Axial Load: 200 kg.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHeight: 12 meters (4 sections).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eWind Resistance: 200 km\/h.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnti-corrosion protection: Electrolytic Galvanization (ASTM B-633).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eApplication: Outdoor (Desert or low-humidity zones).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Componentes Incluidos --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eIncludes the following components\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e \u003cthead style=\"background-color: rgba(150,150,150,0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e4\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/STZ-30-SYSCOM-TOWERS-31572.html\" target=\"_blank\" rel=\"noopener\"\u003eSTZ30\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e30 cm face width tower section.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SCZ-30-P-SYSCOM-TOWERS-191561.html\" target=\"_blank\" rel=\"noopener\"\u003eSCZ30P\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e30 cm tower cap with set screw for lightning rod.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SBA-30-SYSCOM-TOWERS-29102.html\" target=\"_blank\" rel=\"noopener\"\u003eSBA30\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e30 cm tower base.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SAB-30-SYSCOM-TOWERS-29011.html\" target=\"_blank\" rel=\"noopener\"\u003eSAB30\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eTower base anchor.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SJB-30-SYSCOM-TOWERS-29951.html\" target=\"_blank\" rel=\"noopener\"\u003eSJB30\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eGuy wire support flange.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SAP-01-SYSCOM-TOWERS-29051.html\" target=\"_blank\" rel=\"noopener\"\u003eSAP01\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eWall anchor for guy wire.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e12\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-14-HDG-SYSCOM-TOWERS-199560.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-14-HDG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eThimble for guy wire.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e36\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-316-FJG-SYSCOM-TOWERS-199580.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-316-FJG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/16' wire rope clip.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 20px 0; color: inherit;\"\u003eDoes not include guy wire. 100 meters of 1\/8' guy wire (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SRET318CAM-SYSCOM-151126.html\"\u003eSRET-318-CAM\u003c\/a\u003e) or larger diameters are recommended.\u003c\/p\u003e \u003cp style=\"margin: 20px 0; color: inherit;\"\u003eDoes not include turnbuckles. 6 turnbuckles of 1\/2' x 6' are recommended. (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OGJ-SYSCOM-TOWERS-199554.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OGJ\u003c\/a\u003e or \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OQJ-SYSCOM-TOWERS-199557.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OQJ\u003c\/a\u003e).\u003c\/p\u003e \u003cdiv style=\"margin: 20px 0; padding: 15px; border: 1px solid rgba(255, 0, 0, 0.3); border-left: 4px solid rgba(255, 0, 0, 0.5); background-color: rgba(255, 0, 0, 0.05);\"\u003e \u003cp style=\"margin: 0; font-weight: bold; color: inherit;\"\u003eWarning:\u003c\/p\u003e \u003cp style=\"margin: 10px 0 0 0; color: inherit;\"\u003eFailure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will result in the loss of the equipment warranty, and any additional modifications are the responsibility of the installer.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Accesorios Complementarios --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eComplementary accessories (Not included)\u003c\/h3\u003e \u003ch4 style=\"font-size: 18px; margin-top: 20px; color: inherit;\"\u003eSignaling\/Lighting System (Not included)\u003c\/h4\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e \u003cthead style=\"background-color: rgba(150,150,150,0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/EI-GSL-SE-EPCOM-INDUSTRIAL-155623.html\" target=\"_blank\" rel=\"noopener\"\u003eEIGSLSE\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eSelf-contained LED strobe with photocell, solar panel, and battery. Type L810.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/HLU-3R2-EPCOM-INDUSTRIAL-196712.html\" target=\"_blank\" rel=\"noopener\"\u003eHLU3R2\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eMount for EIGSLSE obstruction light.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 20px 0; color: inherit; font-style: italic;\"\u003e* The signaling standard dictates that the tower must be painted in 7 bands of equal size; 4 bands in reddish-orange and 3 in white.\u003c\/p\u003e \u003ch4 style=\"font-size: 18px; margin-top: 20px; color: inherit;\"\u003eLifeline system (Not included)\u003c\/h4\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e \u003cthead style=\"background-color: rgba(150,150,150,0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=SHE-LV-SYSCOM-TOWERS-29815\u0026amp;autodetect=shelv\" target=\"_blank\" rel=\"noopener\"\u003eSHE-LV\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003ePair of mounting brackets.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=S-GULV-SYSCOM-TOWERS-29794\u0026amp;autodetect=sgul\" target=\"_blank\" rel=\"noopener\"\u003eS-GULV\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eLine guide.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e15\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SRET-338-SYSCOM-31077.html\"\u003eSRET-338\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8' cable.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e6\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-38-FJG-SYSCOM-TOWERS-199587.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-38FJG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8' forged cable clip.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-38-HDG-SYSCOM-TOWERS-199562.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-38-HDG\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e3\/8' thimble.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=TRY-ACC-SLIDER-Trylon-161793\u0026amp;autodetect=carro\" target=\"_blank\" rel=\"noopener\"\u003eTRY-ACC-SLIDER\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e(Optional) Safety carriage for installer.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=SYS-USA7B-URREA-174988\u0026amp;autodetect=sysusa\" target=\"_blank\" rel=\"noopener\"\u003eSYS-USA7B\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e(Optional) Suspension harness.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 20px 0; color: inherit; font-style: italic;\"\u003e* NOM-009 makes it mandatory to use systems that stop accidental falls on a structure.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sistema Pararrayo --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eNew! Lightning rod + Grounding kit with cable (Not included)\u003c\/h3\u003e \u003cp style=\"margin: 20px 0; color: inherit;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/KLP-TZ12-PRO-LINKEDPRO-192185.html\" target=\"_blank\" rel=\"noopener\"\u003e \u003cstrong\u003eKLP-TZ12-PRO\u003c\/strong\u003e \u003c\/a\u003e - All-inclusive! Ideal for 12m towers with corona dipole, wiring, and electrodes. \u003c\/p\u003e \u003cp style=\"margin: 20px 0; color: inherit; font-style: italic;\"\u003eOr you can quote the following Grounding or Lightning rod components individually:\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sistema de Tierra Física --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eGrounding System Recommended for Tower and Mounted Equipment (Not included)\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e \u003cthead style=\"background-color: rgba(150,150,150,0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\"\u003eTG45AB\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e45A grounding electrode with electrode, filter, and H2Ohm compound.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\"\u003eS610\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003ePlastic access box.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\"\u003eTGCR11\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eEye connector.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\"\u003eTGAB18\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eRod connector.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGBUSG10-TOTAL-GROUND-75914.html\"\u003eTGBUSG10\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eGrounding bus bar with 1000A capacity insulators (no cabinet).\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 20px 0; color: inherit;\"\u003e* It is recommended to use insulated copper cable 4 AWG (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SLY-287-GRN-INDIANA-176933.html\"\u003eSLY-287-GRN\u003c\/a\u003e) to ground the electrode to the tower. For equipment on the tower, 6 AWG (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SL-Y-291-GRN-100-INDIANA-87721.html\"\u003eSLY-291-GRN\u003c\/a\u003e) can be used.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Sistema Pararrayos Básico --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eBasic Lightning Rod System Recommended for Tower (Not included)\u003c\/h3\u003e \u003cdiv style=\"overflow-x: auto;\"\u003e \u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e \u003cthead style=\"background-color: rgba(150,150,150,0.1);\"\u003e \u003ctr\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003eQuantity\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eModel\u003c\/th\u003e \u003cth style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eDescription\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGTDPC-TOTAL-GROUND-76020.html\"\u003eTGTDPC\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eLightning rod tip with aluminum mast (MASTIL1.2).\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\"\u003eTG45AB\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\"\u003eS610\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eSmall plastic inspection box.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e1\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/ANTIOX-TOTAL-GROUND-75931.html\"\u003eANTIOX\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eAerosol for terminal protection.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e3\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\"\u003eTGCR11\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eEye connector.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e2\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\"\u003eTGAB18\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eRod connector.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3); text-align: center;\"\u003e8\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003e\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAC-TOTAL-GROUND-76016.html\"\u003eTGAC\u003c\/a\u003e\u003c\/td\u003e \u003ctd style=\"padding: 12px; border: 1px solid rgba(150,150,150,0.3);\"\u003eTower insulator.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cp style=\"margin: 20px 0; color: inherit;\"\u003e*The dipole-type tip offers a 72° cone of protection below the coil. It is recommended for areas with low lightning incidence.\u003c\/p\u003e \u003cp style=\"margin: 20px 0; color: inherit;\"\u003e*2\/0 gauge copper cable is recommended for integration (\u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SLY-346-BLK-INDIANA-176872.html\"\u003eSLY-346-BLK\u003c\/a\u003e). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.\u003c\/p\u003e \u003cp style=\"margin: 20px 0; color: inherit;\"\u003eSee the Physical Ground + Lightning Rod connection diagram in the following \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2019\/03\/27\/2ed55\/01REV02-DIPOLO%20CORONA%20Y%20EQUIPO%20EN%20TORRE.pdf\"\u003eDIAGRAM\u003c\/a\u003e.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- Recomendaciones --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRecommendations\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit; list-style: disc;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEnsure the installation is performed by a trained professional.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan to check guy wire tension and tighten hardware.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA stress study must be performed when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in reddish-orange and white, in 7 stripes of equal height, starting and ending with reddish-orange (SYSCOM does not perform tower painting).\u003c\/li\u003e \u003cli\u003eIt is recommended to illuminate the tower, at least at the tip, with a red lamp.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Diagrama Representativo --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRepresentative Diagram: Guy Wire Installation Version 2.0\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" alt=\"Guy Wire Installation Diagram Version 2.0\"\u003e \u003c\/div\u003e \u003c!-- Imágenes de Instalación --\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInstallation Images\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/ARRIOSTRADAS\/TORRES%20IMAGEN.png\" alt=\"Installation Images\"\u003e \u003c\/div\u003e \u003c!-- Separador --\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150,150,150,0.3); margin: 30px 0;\"\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828326453407,"sku":"KTZ-30E-012P","price":14599.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/KTZ30E012P-p.png?v=1783708352","url":"https:\/\/store.glaretum.com\/en\/products\/kit-de-torre-arriostrada-de-techo-de-12-m-con-tramo-stz30-galvanizado-electrolitico-no-incluye-retenida","provider":"Glaretum","version":"1.0","type":"link"}