{"product_id":"kit-de-torre-arriostrada-de-techo-de-12-m-con-tramo-stz30g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","title":"12 m Roof-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003c!-- Logo --\u003e \u003cdiv style=\"text-align: center; margin: 30px 0;\"\u003e \u003cimg style=\"width: 100%; max-width: 300px; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/logotipos\/syscom_towers.png\" alt=\"Logo SYSCOM TOWERS\"\u003e \u003c\/div\u003e \u003c!-- Características Destacadas --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under \u003cstrong style=\"color: inherit;\"\u003eISO 9001:2015\u003c\/strong\u003e standard\n\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHigh elevation \/ Low cost\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e100% section-by-section assembly inspection\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHot-dip galvanized in accordance with \u003cstrong style=\"color: inherit;\"\u003eNMX-H-004-SCFI-2008\u003c\/strong\u003e\n\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIdeal for coastal areas with high humidity or industrial zones\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Características Físicas --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePhysical Characteristics\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMaximum Axial Load: 200 kg\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHeight: 12 meters (4 sections)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eWind resistance: 200 km\/h\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCorrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eApplication: Outdoors (Humid zones)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Componentes del Kit --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eIncludes the following components\u003c\/h3\u003e \u003cp style=\"color: inherit; font-size: 15px; margin-top: 10px; margin-bottom: 20px;\"\u003eGuy wire not included. 100 meters of 1\/8' guy wire \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SRET318CAM-CAMESA-151126.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-318-CAM\u003c\/a\u003e or larger diameters are recommended.\u003c\/p\u003e \u003cp style=\"color: inherit; font-size: 15px; margin-top: 10px; margin-bottom: 20px;\"\u003eTurnbuckles not included. 6 turnbuckles of 1\/2' x 6' are recommended. \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OGJ-SYSCOM-TOWERS-199554.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OGJ\u003c\/a\u003e or \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OQJ-SYSCOM-TOWERS-199557.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OQJ\u003c\/a\u003e.\u003c\/p\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-top: 20px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eKit Components\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 4 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/STZ-30G-SYSCOM-TOWERS-31574.html\" target=\"_blank\" rel=\"noopener\"\u003eSTZ30G\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 30 cm face width tower section\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SCZ-30-PG-SYSCOM-TOWERS-169012.html\" target=\"_blank\" rel=\"noopener\"\u003eSCZ30PG\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 30 cm tower top with lightning rod set screw\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SBA-30G-SYSCOM-TOWERS-29104.html\" target=\"_blank\" rel=\"noopener\"\u003eSBA30G\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 30 cm tower base\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SAB-30G-SYSCOM-TOWERS-29012.html\" target=\"_blank\" rel=\"noopener\"\u003eSAB30G\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Tower base anchor\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SJB-30G-SYSCOM-TOWERS-29952.html\" target=\"_blank\" rel=\"noopener\"\u003eSJB30G\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Guy wire bracket\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 3 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SAP-01G-SYSCOM-TOWERS-29052.html\" target=\"_blank\" rel=\"noopener\"\u003eSAP01G\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Slab or wall anchor for guy wire\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 12 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-14-HDG-SYSCOM-TOWERS-199560.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-14-HDG\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Thimble for guy wire\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 36 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-316-FJG-SYSCOM-TOWERS-199580.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-316-FJG\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 3\/16' cable clamp\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Accesorios Complementarios --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eComplementary accessories (Not included)\u003c\/h3\u003e \u003cdiv style=\"margin-top: 20px;\"\u003e \u003ch4 style=\"font-size: 18px; color: inherit; margin-top: 20px; margin-bottom: 10px;\"\u003eSignaling\/Lighting System (Not included)\u003c\/h4\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSignaling\/Lighting System\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/EI-GSL-SE-EPCOM-INDUSTRIAL-155623.html\" target=\"_blank\" rel=\"noopener\"\u003eEIGSLSE\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Autonomous LED strobe with photocell, solar panel, and battery. Type L810\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/HLU-3R2-EPCOM-INDUSTRIAL-196712.html\" target=\"_blank\" rel=\"noopener\"\u003eHLU3R2\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Mount for EIGSLSE obstruction light\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003cem\u003e* Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 in orange-red and 3 in white.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Sistema de Línea de Vida --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch4 style=\"font-size: 18px; color: inherit; margin-top: 20px; margin-bottom: 10px;\"\u003eLifeline system (Not included)\u003c\/h4\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eLifeline System\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SHE-LV-SYSCOM-TOWERS-29815.html\" target=\"_blank\" rel=\"noopener\"\u003eSHE-LV\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Pair of fastening brackets\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/S-GULV-SYSCOM-TOWERS-29794.html\" target=\"_blank\" rel=\"noopener\"\u003eS-GULV\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Cable guide\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 15 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/S-RET-338CAM-CAMESA-151134.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-338CAM\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 3\/8' cable\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 6 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/NUDO-38-FJG-SYSCOM-TOWERS-199587.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-38FJG\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 3\/8' forged clamp\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-38-HDG-SYSCOM-TOWERS-199562.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-38-HDG\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 3\/8' thimble\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/TRY-ACC-SLIDER2-Trylon-192532.html\" target=\"_blank\" rel=\"noopener\"\u003eTRY-ACC-SLIDER\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e (Optional) Safety slider for installer\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SYS-USA7B-URREA-174988.html\" target=\"_blank\" rel=\"noopener\"\u003eSYS-USA7B\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e (Optional) Suspension harness\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003cem\u003e*NOM-009 mandates the use of systems to arrest accidental falls on a structure.\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Kit Pararrayo --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eNew! Lightning Rod + Grounding Kit with Cable. LINKEDPRO Brand (Not included)\u003c\/h3\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/KLP-TZ12-PRO-LINKEDPRO-BY-EPCOM-192185.html\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eKLP-TZ12-PRO\u003c\/strong\u003e\u003c\/a\u003e - All-inclusive! Ideal for 12m towers with corona dipole, wiring, and electrodes. \u003c\/p\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e \u003cem\u003eOr you can individually quote the following Grounding or Lightning Rod components:\u003c\/em\u003e \u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Sistema de Tierra Física --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRecommended Grounding System for Tower and Equipment (Not included)\u003c\/h3\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eGrounding System\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 45A grounding electrode with electrode, filter, and H2Ohm compound\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Plastic inspection box\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 3 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\" target=\"_blank\" rel=\"noopener\"\u003eTGCR11\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Eye connector\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Rod connector\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGBUSG10-TOTAL-GROUND-75914.html\" target=\"_blank\" rel=\"noopener\"\u003eTGBUSG10\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 1000A capacity ground bus bar with insulators (without cabinet)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e* 4 AWG insulated copper cable \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SLY-287-GRN-INDIANA-176933.html\"\u003eSLY-287-GRN\u003c\/a\u003e is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SL-Y-291-GRN-100-INDIANA-87721.html\"\u003eSLY-291-GRN\u003c\/a\u003e can be used.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Sistema de Pararrayos --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eBasic Recommended Lightning Rod System for Tower (Not included)\u003c\/h3\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eLightning Rod System\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGTDPC-TOTAL-GROUND-76020.html\" target=\"_blank\" rel=\"noopener\"\u003eTGTDPC\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Lightning rod tip with aluminum mast (MASTIL1.2)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e 45 Amp electrode. Includes a bag of impedance-improving compound (H2OHM), compass, and level\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Small plastic inspection box\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/ANTIOX-TOTAL-GROUND-75931.html\" target=\"_blank\" rel=\"noopener\"\u003eANTIOX\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Terminal protection spray\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 3 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGCR11-TOTAL-GROUND-76026.html\" target=\"_blank\" rel=\"noopener\"\u003eTGCR11\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Eye connector\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 2 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Rod connector\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 8 | \u003cstrong\u003eModel:\u003c\/strong\u003e \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/www.syscom.mx\/producto\/TGAC-TOTAL-GROUND-76016.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAC\u003c\/a\u003e | \u003cstrong\u003eDescription:\u003c\/strong\u003e Tower insulator\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.\u003c\/p\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e*2\/0 gauge copper cable \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/www.syscom.mx\/producto\/SLY-346-BLK-INDIANA-176872.html\"\u003eSLY-346-BLK\u003c\/a\u003e is recommended for the integration. Considering a maximum installation distance of 3 meters from the tower, approximately 8 meters are used.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e\n\u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003eSee the Earth Ground + Lightning Rod connection diagram in the following \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2019\/03\/27\/2ed55\/01REV02-DIPOLO%20CORONA%20Y%20EQUIPO%20EN%20TORRE.pdf\"\u003eDIAGRAM\u003c\/a\u003e.\u003c\/p\u003e \u003c\/div\u003e  \u003c!-- Recomendaciones --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRecommendations\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; margin-top: 15px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEnsure the installation is performed by a trained professional\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan to check guy wire tension and tighten hardware\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA stress study must be conducted when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in orange-red and white, in 7 bands of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting work)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIt is recommended to illuminate the tower at least at the tip with a red light\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Diagrama Representativo --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eRepresentative Diagram: Guy Wire Installation Version 2.0\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" alt=\"Guy Wire Installation Diagram Version 2.0\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Imágenes de Instalación --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInstallation Images\u003c\/h3\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/ARRIOSTRADAS\/TORRES%20IMAGEN.png\" alt=\"Installation Images\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Separador final --\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e ","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828323537055,"sku":"KTZ-30G-012P","price":18699.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/KTZ30G012P-p.png?v=1783708201","url":"https:\/\/store.glaretum.com\/en\/products\/kit-de-torre-arriostrada-de-techo-de-12-m-con-tramo-stz30g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","provider":"Glaretum","version":"1.0","type":"link"}