{"product_id":"kit-de-torre-arriostrada-de-techo-de-21-m-con-tramo-stz30g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","title":"21 m Roof Guyed Tower Kit with Hot-Dip Galvanized STZ30G Section (Guy wire not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 20px;\"\u003e \u003cdiv style=\"display: flex; justify-content: center;\"\u003e\u003cimg style=\"width: 100%; max-width: 300px; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/logotipos\/syscom_towers.png\" alt=\"SYSCOM TOWERS Logo\"\u003e\u003c\/div\u003e \u003cdiv\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Features\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under \u003cstrong style=\"color: inherit;\"\u003eISO 9001:2015\u003c\/strong\u003e standards.\n\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHigh elevation \/ Low cost.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e100% section-by-section assembly inspection.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHot-dip galvanized in accordance with \u003cstrong style=\"color: inherit;\"\u003eNMX-H-004-SCFI-2008\u003c\/strong\u003e.\n\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIdeal for high-humidity coastal areas or industrial sites.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePhysical Characteristics\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMaximum Axial Load: 200 kg.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eHeight: 21 meters (7 sections).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eWind Resistance: 200 km\/h.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eApplication: Outdoor (Humid zones).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eIncludes the following components\u003c\/h3\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-top: 15px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 280px; border: 1px solid rgba(150,150,150,0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150,150,150,0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eTower Components\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e7 units - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/STZ-30G-SYSCOM-TOWERS-31574.html\" target=\"_blank\" rel=\"noopener\"\u003eSTZ30G\u003c\/a\u003e: 30 cm face width tower section.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SCZ-30-PG-SYSCOM-TOWERS-169012.html\" target=\"_blank\" rel=\"noopener\"\u003eSCZ30PG\u003c\/a\u003e: 30 cm tower top with lightning rod set screw.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SBA-30G-SYSCOM-TOWERS-29104.html\" target=\"_blank\" rel=\"noopener\"\u003eSBA30G\u003c\/a\u003e: 30 cm tower base.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SAB-30G-SYSCOM-TOWERS-29012.html\" target=\"_blank\" rel=\"noopener\"\u003eSAB30G\u003c\/a\u003e: Tower base anchor.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e4 units - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SJB-30G-SYSCOM-TOWERS-29952.html\" target=\"_blank\" rel=\"noopener\"\u003eSJB30G\u003c\/a\u003e: Guy wire attachment flange.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e3 units - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SAP-01G-SYSCOM-TOWERS-29052.html\" target=\"_blank\" rel=\"noopener\"\u003eSAP01G\u003c\/a\u003e: Slab or wall anchor for guy wire.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e24 units - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-14-HDG-SYSCOM-TOWERS-199560.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-14-HDG\u003c\/a\u003e: Guy wire thimble.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e72 units - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/NUDO-316-FJG-SYSCOM-TOWERS-199580.html\" target=\"_blank\" rel=\"noopener\"\u003eNUDO-316-FJG\u003c\/a\u003e: 3\/16' cable clamp.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; color: inherit;\"\u003e\u003cstrong style=\"color: inherit;\"\u003eGuy wire not included.\u003c\/strong\u003e 290 meters of 1\/8' guy wire (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SRET318CAM-CAMESA-151126.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-318-CAM\u003c\/a\u003e) or larger diameters are recommended.\u003c\/p\u003e \u003cp style=\"margin-top: 15px; color: inherit;\"\u003e\u003cstrong style=\"color: inherit;\"\u003eTurnbuckles not included.\u003c\/strong\u003e 12 1\/2' x 6' turnbuckles are recommended (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OGJ-SYSCOM-TOWERS-199554.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OGJ\u003c\/a\u003e or \u003ca href=\"https:\/\/www.syscom.mx\/producto\/TEN-1\/2X6-OQJ-SYSCOM-TOWERS-199557.html\" target=\"_blank\" rel=\"noopener\"\u003eTEN1\/2X6OQJ\u003c\/a\u003e).\u003c\/p\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003cem\u003e**Failure to use installation accessories such as flanges, tower base, tower anchor, or guy wire anchors will be considered a voiding of the equipment warranty, and any additional adaptation is the responsibility of the installer.**\u003c\/em\u003e\u003c\/p\u003e \u003c\/div\u003e \u003cdiv\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eComplementary Accessories (Not included)\u003c\/h3\u003e \u003ch4 style=\"font-size: 18px; margin-top: 15px; color: inherit; opacity: 0.8;\"\u003eSignaling\/Lighting System (Not included)\u003c\/h4\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-top: 10px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 280px; border: 1px solid rgba(150,150,150,0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150,150,150,0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eComponents\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e2 units - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/EI-GSL-SE-EPCOM-INDUSTRIAL-155623.html\" target=\"_blank\" rel=\"noopener\"\u003eEIGSLSE\u003c\/a\u003e: Autonomous LED strobe light with photocell, solar panel, and battery. Type L810.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e2 units - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/HLU-3R2-EPCOM-INDUSTRIAL-196712.html\" target=\"_blank\" rel=\"noopener\"\u003eHLU3R2\u003c\/a\u003e: Mounting for EIGSLSE obstruction light.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003cem\u003e*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 bands in reddish-orange and 3 in white.\u003c\/em\u003e\u003c\/p\u003e \u003ch4 style=\"font-size: 18px; margin-top: 15px; color: inherit; opacity: 0.8;\"\u003eLifeline system (Not included)\u003c\/h4\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-top: 10px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 280px; border: 1px solid rgba(150,150,150,0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150,150,150,0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eComponents\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SHE-LV-SYSCOM-TOWERS-29815.html\" target=\"_blank\" rel=\"noopener\"\u003eSHE-LV\u003c\/a\u003e: Pair of mounting brackets.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/S-GULV-SYSCOM-TOWERS-29794.html\" target=\"_blank\" rel=\"noopener\"\u003eS-GULV\u003c\/a\u003e: Line guide.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e24 units - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/S-RET-338CAM-CAMESA-151134.html\" target=\"_blank\" rel=\"noopener\"\u003eSRET-338CAM\u003c\/a\u003e: 3\/8' cable.\u003c\/li\u003e \u003cli style=\"margin-bottom: 6 units - \u0026lt;a href=\" https: target=\"_blank\" rel=\"noopener\"\u003eNUDO-38FJG: 3\/8' forged cable clamp.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e2 units - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/CUELLO-38-HDG-SYSCOM-TOWERS-199562.html\" target=\"_blank\" rel=\"noopener\"\u003eCUELLO-38-HDG\u003c\/a\u003e: 3\/8' thimble.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/TRY-ACC-SLIDER2-Trylon-192532.html\" target=\"_blank\" rel=\"noopener\"\u003eTRY-ACC-SLIDER\u003c\/a\u003e: (Optional) Safety carriage for installer.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"https:\/\/www.syscom.mx\/producto\/SYS-USA7B-URREA-174988.html\" target=\"_blank\" rel=\"noopener\"\u003eSYS-USA7B\u003c\/a\u003e: (Optional) Suspension harness.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003cem\u003e*NOM-009 mandates the use of systems that stop accidental falls on a structure.\u003c\/em\u003e\u003c\/p\u003e \u003ch4 style=\"font-size: 18px; margin-top: 15px; color: inherit; opacity: 0.8;\"\u003eNew! Lightning Rod Kit + Grounding with Cable (Not included)\u003c\/h4\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003ca href=\"https:\/\/www.syscom.mx\/producto\/KLP-TZ21-PRO-LINKEDPRO-BY-EPCOM-192188.html\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eKLP-TZ21-PRO\u003c\/strong\u003e\u003c\/a\u003e - All-inclusive! Ideal for 21m towers with corona dipole, wiring, and electrodes.\u003c\/p\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003cem\u003eYou can also quote the following Grounding or Lightning Rod components individually:\u003c\/em\u003e\u003c\/p\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 25px; color: inherit; opacity: 0.8;\"\u003eRecommended Grounding System for Tower and Mounted Equipment (Not included)\u003c\/h3\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-top: 15px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 280px; border: 1px solid rgba(150,150,150,0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150,150,150,0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eComponents\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e: 45A grounding electrode with electrode, filter, and H2Ohm compound.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e: Plastic access box.\u003c\/li\u003e \u003cli style=\"margin-bottom: 3 units - \u0026lt;a href=\" http: target=\"_blank\" rel=\"noopener\"\u003eTGCR11: Eye connector.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e2 units - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e: Rod connector.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGBUSG10-TOTAL-GROUND-75914.html\" target=\"_blank\" rel=\"noopener\"\u003eTGBUSG10\u003c\/a\u003e: Connection bar with 1000A capacity insulators (No cabinet).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e* 4 AWG coated copper cable (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SLY-287-GRN-INDIANA-176933.html\" target=\"_blank\" rel=\"noopener\"\u003eSLY-287-GRN\u003c\/a\u003e) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SL-Y-291-GRN-100-INDIANA-87721.html\" target=\"_blank\" rel=\"noopener\"\u003eSLY-291-GRN\u003c\/a\u003e) can be used.\u003c\/p\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 25px; color: inherit; opacity: 0.8;\"\u003eRecommended Basic Lightning Protection System for Tower (Not included)\u003c\/h3\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px; margin-top: 15px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 280px; border: 1px solid rgba(150,150,150,0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150,150,150,0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eComponents\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGTDPC-TOTAL-GROUND-76020.html\" target=\"_blank\" rel=\"noopener\"\u003eTGTDPC\u003c\/a\u003e: Corona dipole lightning rod tip.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TG45AB-TOTAL-GROUND-75917.html\" target=\"_blank\" rel=\"noopener\"\u003eTG45AB\u003c\/a\u003e: 45 Amp electrode. With one bag of improving compound (H2OHM), compass, and level.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/S610-TOTAL-GROUND-75929.html\" target=\"_blank\" rel=\"noopener\"\u003eS610\u003c\/a\u003e: Small plastic access box.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e1 unit - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/ANTIOX-TOTAL-GROUND-75931.html\" target=\"_blank\" rel=\"noopener\"\u003eANTIOX\u003c\/a\u003e: Terminal protection spray.\u003c\/li\u003e \u003cli style=\"margin-bottom: 3 units - \u0026lt;a href=\" http: target=\"_blank\" rel=\"noopener\"\u003eTGCR11: Eye connector.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e2 units - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGAB18-TOTAL-GROUND-76028.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAB18\u003c\/a\u003e: Rod connector.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e14 units - \u003ca href=\"http:\/\/www.syscom.mx\/producto\/TGAC-TOTAL-GROUND-76016.html\" target=\"_blank\" rel=\"noopener\"\u003eTGAC\u003c\/a\u003e: Down conductor insulator.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003cem\u003e*The dipole tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.\u003c\/em\u003e\u003c\/p\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003e\u003cem\u003e*2\/0 gauge copper cable is recommended for integration (\u003ca href=\"https:\/\/www.syscom.mx\/producto\/SLY-346-BLK-INDIANA-176872.html\" target=\"_blank\" rel=\"noopener\"\u003eSLY-346-BLK\u003c\/a\u003e). Considering the electrode is installed at a maximum of 3 meters from the tower, approx. 8 meters are used.\u003c\/em\u003e\u003c\/p\u003e \u003cp style=\"margin-top: 15px; font-size: 14px; color: inherit;\"\u003eSee the Grounding + Lightning Rod connection diagram in the following \u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2019\/03\/27\/2ed55\/01REV02-DIPOLO%20CORONA%20Y%20EQUIPO%20EN%20TORRE.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDIAGRAM\u003c\/a\u003e.\u003c\/p\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 25px; color: inherit; opacity: 0.8;\"\u003eRecommendations\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; margin-top: 15px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEnsure installation is carried out by a trained professional.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan for checking guy wire tension and adjusting hardware.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending, leading to structural failure.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in reddish-orange and white, in 7 bands of equal height, starting and ending with reddish-orange (SYSCOM does not perform tower painting).\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIt is recommended to light the tower at least at the top with a red lamp.\u003c\/li\u003e \u003c\/ul\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 25px; color: inherit; opacity: 0.8;\"\u003eRepresentative Diagram: Guy Wire Installation Version 2.0\u003c\/h3\u003e \u003cdiv style=\"margin-top: 15px; margin-bottom: 30px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" alt=\"Guy Wire Installation Diagram Version 2.0\"\u003e \u003c\/div\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 25px; color: inherit; opacity: 0.8;\"\u003eInstallation Images\u003c\/h3\u003e \u003cdiv style=\"margin-top: 15px; margin-bottom: 30px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/ARRIOSTRADAS\/TORRES%20IMAGEN.png\" alt=\"Installation Images\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828330582175,"sku":"KTZ-30G-021P","price":29099.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/KTZ30G021P-p.png?v=1783708563","url":"https:\/\/store.glaretum.com\/en\/products\/kit-de-torre-arriostrada-de-techo-de-21-m-con-tramo-stz30g-galvanizada-por-inmersion-en-caliente-no-incluye-retenida","provider":"Glaretum","version":"1.0","type":"link"}