{"product_id":"modulo-de-entrada-de-zona-convencional-para-caja-4-clase-a-y-b-0400-01840","title":"Conventional Zone Input Module for 4\" Box, Class A and B (0400-01840)","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eMain Features\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMonitors:\u003c\/strong\u003e 2-wire 24VDC conventional smoke detectors\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eSupervision:\u003c\/strong\u003e External power source supply\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eReported states:\u003c\/strong\u003e Normal, Open, or Alarm\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003ePower requirement:\u003c\/strong\u003e 24VDC external power source\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Class A or Class B SLC loops\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eSupply voltage (S-SC):\u003c\/strong\u003e 25.3 ~ 39 VDC\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAuxiliary voltage:\u003c\/strong\u003e 18.8 ~ 27.2 VDC\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAverage consumption (on S-SC line):\u003c\/strong\u003e 670µA\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e2-wire detector loop current:\u003c\/strong\u003e 1mA Max. in standby\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCurrent from auxiliary source:\u003c\/strong\u003e 60mA Max.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eEOL resistor:\u003c\/strong\u003e 4.7K ohms\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaximum quantity per loop:\u003c\/strong\u003e 127\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAlarm threshold:\u003c\/strong\u003e \u0026lt;1.5K ohms\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOpen circuit threshold:\u003c\/strong\u003e \u0026gt;10K ohms\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaximum loop resistance:\u003c\/strong\u003e 50 ohms (total cable length)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eOperating Conditions\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e 0°C ~ 49°C (32°F ~ 120°F)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 90% RH non-condensing\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eCertifications\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eUL 864 9th Edition Listed\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCalifornia State Fire Marshal 3033215\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eUL Listed 1481\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eDimensions\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e4.2\" Wide x 4.7\" High x 1.4\" Deep\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eMounting in 4\" square electrical box\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eCompatibility\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eWith conventional detectors\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSLR, SIJ, SLK, SLV, DCD, DFE and SIH series\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDCP (Digital Communication Protocol)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eInstallation\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAddressable via handheld programmer\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eProgrammable address: 1 to 127\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eMaximum 127 devices per SLC loop\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eMaximum 25 detectors per zone\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eAdditional Features\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eBi-color LED for status indication\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSupplied with plastic cover\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eMonitoring LED visible from the outside\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDesigned for analog addressable systems\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eReliable and fast communication in emergencies\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eApplications\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAnalog fire alarm systems\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eMonitoring of zones with conventional detectors\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSystems with UL 864 9th Edition requirements\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCommercial and industrial installations\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eConnections\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTB1 connector for power supply connection\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTB2 connector for SLC loop connection\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eJumpers for wiring configuration\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eLimitations\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDo not mix alarm and supervisory devices in the same module\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eLimited to 25 conventional detectors per zone\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eRequires correct jumper configuration based on wiring type\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\n\n\n\u003c\/div\u003e","brand":"HOCHIKI","offers":[{"title":"Default Title","offer_id":62836744388767,"sku":"CZM","price":1399.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/CZM-p.png?v=1784841079","url":"https:\/\/store.glaretum.com\/en\/products\/modulo-de-entrada-de-zona-convencional-para-caja-4-clase-a-y-b-0400-01840","provider":"Glaretum","version":"1.0","type":"link"}