{"product_id":"panel-de-deteccion-de-incendio-direccionable-hasta-198-puntos-99-detectores-y-99-modulos-con-tecnologia-sk-incluye-comunicador-clss-modelo-hw-av-lte-m-la","title":"Fire Alarm Control Panel \/ Addressable \/ Up to 198 Points \/ 99 Detectors and 99 Modules with SK Technology \/ Includes CLSS Communicator Model HW-AV-LTE-M-LA","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003c!-- Contenedor de imágenes --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px; justify-content: center;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 200px; min-width: 150px;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.3); border-radius: 8px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/yhermosillo\/SILENT%20KNIGHT\/IntelliKnight.png\" alt=\"\" class=\"fr-fic fr-dii\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 200px; min-width: 150px;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/6808\/158633-paneles.jpg\" alt=\"\" class=\"fr-fic fr-dii\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 200px; min-width: 150px;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/6808\/158633-diagrama_sk.jpg\" alt=\"\" class=\"fr-fic fr-dii\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Sección de contenido --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eGeneral Description\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 15px; color: inherit;\"\u003eThe 6808 is an addressable Fire Alarm Control Panel (FACP) that can be configured to support up to a maximum of 198 points. It has a built-in Signaling Line Circuit (SLC), which can support 99 detectors and 99 System Sensor® (SK) modules or 127 Hochiki® (SD) devices.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\n\n\u003c!-- Sección de características --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eFeatures\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eA common communication and annunciation path of up to 17 panels can be connected via copper or fiber optics\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eA designated panel is configured as the communicator for the other panels within the network\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFeatures a dual POT phone line communicator and an IP communicator\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eA cellular communicator can be installed optionally\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCan be enhanced using modules such as the 6860 remote annunciator\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eThe 6860 remote annunciator has 4 programmable function keys that help automate tasks and reduce wasted time at the panel\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCompatibility with SWIFT® wireless devices provides intelligent detection options through a Class A mesh network\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eIdeal for locations where wiring is not permitted, or for a simple installation of a new fire detection system\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eTechnical Details\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSWIFT devices can be combined with other wired devices compatible with the 6808\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSWIFT devices are only compatible with System Sensor (SK) devices\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eNot compatible with Hochiki (SD) devices\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eHas one Form C trouble relay\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTwo programmable Form C relays\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDrift compensation\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003ePre-trouble and maintenance alert\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCalibration trouble alert\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Sección de compatibilidad --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eCompatibility\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSWIFT devices\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eSystem Sensor® (SK)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eHochiki® (SD) - Maximum 127 devices\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eCommunications\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eNetwork of up to 17 panels\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCopper or fiber optics\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDual POT phone line communicator\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eIP communicator (optional)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCellular communicator (optional)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eAdvanced Functions\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eForm C trouble relay\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eTwo programmable Form C relays\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDrift compensation\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003ePre-trouble and maintenance alert\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eCalibration trouble alert\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Separador final --\u003e\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\n\n\n\u003c\/div\u003e","brand":"SILENT KNIGHT BY HONEYWELL","offers":[{"title":"Default Title","offer_id":62828251873439,"sku":"6808-PAT","price":26099.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/portada_0S400_21a16f20-0953-458f-ad2e-032cbdb58324.png?v=1783704709","url":"https:\/\/store.glaretum.com\/en\/products\/panel-de-deteccion-de-incendio-direccionable-hasta-198-puntos-99-detectores-y-99-modulos-con-tecnologia-sk-incluye-comunicador-clss-modelo-hw-av-lte-m-la","provider":"Glaretum","version":"1.0","type":"link"}