{"product_id":"pdu-monitoreable-mi-para-distribucion-de-energia-enchufe-de-entrada-nema-5-15p-con-8-salidas-5-20r-horizontal-19in-120-vca-20-amp-1ur","title":"Metered Input (MI) PDU for Power Distribution, NEMA 5-15P Input Plug, with 8 5-20R Outlets, 19in Horizontal, 120 VAC, 20 Amp, 1U","description":"\u003cp\u003e\u003c\/p\u003e\u0026lt; div style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u0026gt;\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eGeneral Description\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 15px; color: inherit;\"\u003ePanduit SmartZone G5 iPDUs are more than just power distribution units and power meters. These iPDUs monitor power in the data center environment (at the cabinet level) by continuously scanning for electrical circuit overloads and physical environmental conditions that put critical IT equipment at risk. Panduit iPDUs provide comprehensive and accurate power metering data to use power resources efficiently, make informed capacity planning decisions, improve uptime, measure PUE (Power Usage Effectiveness), and drive green data center initiatives to save energy and money.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 15px; color: inherit;\"\u003ePanduit Rack iPDUs are easily installed in Panduit or third-party cabinets. They securely and efficiently manage and distribute power to multiple devices via a single power input connector, per PDU, to improve scalability as a network grows.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSwitched Monitoring Series (MS)\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\u003cli style=\"margin-bottom: 5px;\"\u003ePDUs with aggregate power monitoring and outlet-level switching capabilities, individual or by group. Allows for power-on sequencing, rebooting equipment, or restricting unauthorized use of each outlet.\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eEnergy Metering and Monitoring\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eMeter for energy consumption, watt-hour, PDU level (kWh), power measurements at PDU level (W), input phase level power measurements (V, A, VA, kWh, pf), and circuit breaker level current measurements.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEmbedded memory log to record\/query\/report historical data.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAlarm thresholds and user-customizable notifications.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAlarm thresholds and user-customizable notifications.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eOutlet-Level Control\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eRemote On\/Off control per individual outlet.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eUser-defined power-on delay to sequence IT equipment.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAutomatic sequencing to prevent inrush current overload.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eUser security at the outlet level, with assignable roles and user access.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSecurity and Environmental Management\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eOptional Plug \u0026amp; Play environmental sensors. Include temperature, humidity, dry contact, and water leak.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAlarm thresholds and user-customizable notifications.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eNetwork Management and Local Display Interface\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eOLED screen, the largest in its class, high visibility.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFull network management and alerting capabilities, supporting HTTP, HTTPS, SSH, Telnet, SNMP, FTP, and email.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eStrong encryption, passwords, and advanced authorization options, including local permissions, LDAP\/S, and Active Directory.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eDaisy-chaining for PDUs in up to 4 racks, and 32 environmental sensors, via a single IP address.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eTechnical Specifications\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eInput voltage:\u003c\/strong\u003e 120 VAC\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOutput voltage:\u003c\/strong\u003e 120 VAC\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eInput current:\u003c\/strong\u003e 20 Amp\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eApparent power:\u003c\/strong\u003e 1.9 kVA\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eInput Plug Type:\u003c\/strong\u003e NEMA 5-20P\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCable length:\u003c\/strong\u003e 3 m.\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eReceptacle Types:\u003c\/strong\u003e (8) NEMA 5-20R\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 433.5 x 43.5 x 270 mm (Width x Height x Depth)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRack Units:\u003c\/strong\u003e 1\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 10 to 60 ºC\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -20 to 60 ºC\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eNon-operating relative humidity:\u003c\/strong\u003e 5 to 95%\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eStorage relative humidity:\u003c\/strong\u003e 5 to 95%\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n","brand":"PANDUIT","offers":[{"title":"Default Title","offer_id":62828101402783,"sku":"P08D10M","price":22099.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/portada_0S400_b8b79a68-dc8a-497b-8356-9a02aa1c6884.png?v=1783695620","url":"https:\/\/store.glaretum.com\/en\/products\/pdu-monitoreable-mi-para-distribucion-de-energia-enchufe-de-entrada-nema-5-15p-con-8-salidas-5-20r-horizontal-19in-120-vca-20-amp-1ur","provider":"Glaretum","version":"1.0","type":"link"}