{"product_id":"pdu-monitoreable-y-switchable-ms-para-distribucion-de-energia-enchufe-de-entrada-nema-l6-30p-con-12-salidas-c13-y-4-salidas-c19-horizontal-19in-208-vca-30-amp-2ur","title":"Monitored and Switched (MS) Power Distribution PDU, NEMA L6-30P Input Plug, with 12 C13 Outlets and 4 C19 Outlets, 19in Horizontal, 208 VAC, 30 Amp, 2U","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003cp style=\"font-size: 15px; color: inherit; margin: 0 0 15px 0;\"\u003eThe Panduit SmartZone G5 iPDU is more than just a power distribution unit and energy meter. These iPDU units monitor power in a data center environment (at the cabinet level) by continuously scanning for electrical circuit overloads and physical environmental conditions that put critical IT equipment at risk. Panduit iPDUs provide comprehensive and accurate power metering data to efficiently utilize power resources, make informed capacity planning decisions, improve uptime, measure PUE (Power Usage Effectiveness), and drive green data center initiatives to save energy and money.\u003c\/p\u003e \u003cp style=\"font-size: 15px; color: inherit; margin: 0 0 15px 0;\"\u003ePanduit Rack iPDUs are easily installed in Panduit or third-party cabinets. They securely and efficiently manage and distribute power to multiple devices through a single power input connector per PDU to improve scalability as a network grows.\u003c\/p\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; margin-bottom: 15px; color: inherit; opacity: 0.8;\"\u003eSwitched Monitoring Series (MS)\u003c\/h3\u003e \u003cp style=\"font-size: 15px; color: inherit; margin: 0 0 15px 0;\"\u003ePDUs with aggregated power monitoring and outlet-level switching capabilities, either individual or by group. Allows for power-on sequencing, rebooting equipment, or restricting unauthorized use of each outlet.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003ePDU Power Metering and Monitoring\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMeter for energy consumption, watt-hour, PDU level (kWh), PDU level power measurements (W), Input Phase level power measurements (V, A, VA, kWh, pf), and circuit breaker level current measurements.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEmbedded memory log to record\/query\/report historical data.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAlarm thresholds and custom user-defined notifications.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAlarm thresholds and custom user-defined notifications.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eOutlet-Level Control\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRemote On\/Off control per individual outlet.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eUser-defined power-on time delay to sequence IT equipment.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAutomatic sequencing to prevent inrush current overload.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eUser security at the outlet level, with assignable roles and user access.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eSecurity and Environmental Management\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eOptional Plug \u0026amp; Play environmental sensors. Include temperature, humidity, dry contact, and water leak.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAlarm thresholds and custom user-defined notifications.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eNetwork Management and Local Display Interface\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eOLED display, the largest in its class, high visibility.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eFull network management and alerting capabilities, supporting HTTP, HTTPS, SSH, Telnet, SNMP, FTP, and email.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eStrong encryption, passwords, and advanced authorization options, including local permissions, LDAP\/S, and Active Directory.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDaisy-chaining for PDUs in up to 4 racks and 32 environmental sensors through a single IP address.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003eTechnical Specifications\u003c\/div\u003e \u003cdiv style=\"padding: 15px; color: inherit;\"\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 208 VAC\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 208 VAC\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 30 Amp\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eApparent Power:\u003c\/strong\u003e 5 kVA\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eInput Plug Type:\u003c\/strong\u003e NEMA L6-30P\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\u003cimg style=\"width: 40px; height: 40px; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/www.cyberpower.com\/mx\/es\/File\/GetImageByDocId\/GeneralAttribute-246\" alt=\"\"\u003e\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 3 m.\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eReceptacle Types:\u003c\/strong\u003e 12 C13 and 4 C19\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 444 x 87 x 270 mm (Width x Height x Depth)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRack Units:\u003c\/strong\u003e 2\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 10 to 60 ºC\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -20 to 60 ºC\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOperating Relative Humidity:\u003c\/strong\u003e 5 to 95%\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eStorage Relative Humidity:\u003c\/strong\u003e 5 to 95%\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003c\/div\u003e","brand":"PANDUIT","offers":[{"title":"Default Title","offer_id":62837124792479,"sku":"P16E19M","price":36899.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/P16E19M-p.png?v=1784919599","url":"https:\/\/store.glaretum.com\/en\/products\/pdu-monitoreable-y-switchable-ms-para-distribucion-de-energia-enchufe-de-entrada-nema-l6-30p-con-12-salidas-c13-y-4-salidas-c19-horizontal-19in-208-vca-30-amp-2ur","provider":"Glaretum","version":"1.0","type":"link"}