{"product_id":"rack-de-cuatro-postes-estandar-de-19-rieles-con-orificio-para-tuerca-enjaulada-profundidad-ajustable-de-23-a-42-in-45-unidades-de-rack-color-negro","title":"Standard 19\" 4-Post Rack, Cage Nut Rails, Adjustable Depth 23-42 in, 45U, Black","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\u003cp style=\"text-align: justify; font-size: 16px; color: inherit; opacity: 0.9;\"\u003eThe Panduit Adjustable Depth 4-Post Rack System is designed to support network equipment in data centers, telecommunications rooms, and laboratory environments. Manufactured from UL-certified welded steel with a load capacity of 2000 lbs (907 kg), it complies with the EIA\/ECA-310-E standard for mounting 19-inch wide EIA equipment. Its adjustable depth from 23\" to 42\" (584.2 to 1066.8 mm) in 0.5\" increments offers maximum flexibility with a single part number, while the self-squaring design with front-to-back braces installed on two axes ensures rack squareness during assembly. The structure, fully electrically bonded via paint-piercing hardware, eliminates the need for additional grounding components and incorporates eight masked grounding locations for optimal ground terminal connection. Available in 7-foot (45 RU, 84.13\" \/ 2136.9 mm high) and 8-foot (52 RU, 96.13\" \/ 2441.7 mm high) versions in black or white, this rack accepts NetRunner™ and PatchRunner™ 2 vertical cable managers, as well as accessories like PDU brackets, vertical tie-down brackets, and top trays, forming a comprehensive cable management system that maximizes airflow and accessibility.\u003c\/p\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003eGeneral Features\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eStandard:\u003c\/strong\u003e EIA\/ECA-310-E\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRack Units (RU):\u003c\/strong\u003e 45 RU (7 ft) \u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMounting Width:\u003c\/strong\u003e 19\" for EIA equipment\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAdjustable Depth:\u003c\/strong\u003e 23\" to 42\" in 0.5\" increments (584.2 to 1066.8 mm)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Welded steel\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eLoad Capacity:\u003c\/strong\u003e 2000 lbs (907 kg)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCertification:\u003c\/strong\u003e UL Listed\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMounting Rails:\u003c\/strong\u003e #12-24 threaded (AR4P) or cage nut style with square opening (AR4PCN)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRU Numbering:\u003c\/strong\u003e Printed on rails, numbered bottom-to-top\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eSelf-Squaring Design:\u003c\/strong\u003e Front-to-back braces on two axes\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eFeet:\u003c\/strong\u003e Inward-facing to reduce total footprint and improve tile alignment\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eBonded Structure:\u003c\/strong\u003e Paint-piercing hardware electrically bonds the rack during assembly\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eGrounding Points:\u003c\/strong\u003e 8 masked locations for ground terminal connection\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e PEM studs and carriage bolts eliminate the need for a second wrench\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAvailable Colors:\u003c\/strong\u003e Black (standard) and White (WH suffix)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Accepts shelves, equipment brackets, NetRunner™ and PatchRunner™ 2 vertical cable managers, PDUs, waterfalls, and vertical tie-down brackets\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003ePerformance and Capacity\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\n\n\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eLoad Capacity:\u003c\/strong\u003e 2000 lbs (907 kg)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRack Units:\u003c\/strong\u003e 45 RU (7 ft) or 52 RU (8 ft)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eDepth Range:\u003c\/strong\u003e 23\" to 42\" (584.2 to 1066.8 mm)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAdjustment Increments:\u003c\/strong\u003e 0.5\" (12.7 mm)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCompliance Standard:\u003c\/strong\u003e EIA\/ECA-310-E\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCertification:\u003c\/strong\u003e UL Listed\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRail Type:\u003c\/strong\u003e #12-24 threaded or cage nut (square opening)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eRack Numbering:\u003c\/strong\u003e Printed bottom-to-top for quick location\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eFoot Design:\u003c\/strong\u003e Inward-facing to reduce front-to-back footprint\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp style=\"font-size: 12px; opacity: 0.7; margin-top: 10px;\"\u003e*8-foot versions: add \"96\" suffix to the part number (Ex: AR4P96, AR4PCN96)\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003ePhysical and Electrical\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e45 RU Height:\u003c\/strong\u003e 84.13\" (2136.9 mm)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003e52 RU Height:\u003c\/strong\u003e 96.13\" (2441.7 mm)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 20.31\" (515.9 mm)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 23.00\" to 42.00\" (584.2 to 1066.8 mm) adjustable\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eConstruction Material:\u003c\/strong\u003e Welded steel\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eFinish:\u003c\/strong\u003e Black or White (WH suffix)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAssembly Method:\u003c\/strong\u003e PEM studs and carriage bolts — no second wrench required\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eElectrical Bonding:\u003c\/strong\u003e Paint-piercing hardware bonds the entire structure during assembly\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eGrounding Points:\u003c\/strong\u003e 8 masked locations for optimal terminal position selection\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Not specified — consult full technical specification sheet\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e Not specified — data center and telecom room environment\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 250px; border: 1px solid rgba(150, 150, 150, 0.4); border-radius: 8px; overflow: hidden; display: flex; flex-direction: column;\"\u003e\n\n\u003cdiv style=\"padding: 15px; border-bottom: 1px solid rgba(150, 150, 150, 0.2); font-weight: bold; font-size: 18px; color: inherit;\"\u003e\u003cspan style=\"font-size: 24px;\"\u003ePackage Contents\u003c\/span\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px; color: inherit;\"\u003e\u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; list-style-type: disc;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFront and rear weldments\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eFront-to-back braces for both axes\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eEquipment mounting rails (#12-24 threaded or cage nut depending on model)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eAssembly hardware with PEM studs and carriage bolts\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003ePaint-piercing hardware for electrical bonding\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eInward-facing feet\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e8 masked grounding points\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003c\/div\u003e\n\n\u003cbr\u003e\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"PANDUIT","offers":[{"title":"Default Title","offer_id":62837128069279,"sku":"AR4PCN","price":24799.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/portada_0S400_5a19ce31-0884-4c74-a7f3-340558a57e3b.png?v=1784919923","url":"https:\/\/store.glaretum.com\/en\/products\/rack-de-cuatro-postes-estandar-de-19-rieles-con-orificio-para-tuerca-enjaulada-profundidad-ajustable-de-23-a-42-in-45-unidades-de-rack-color-negro","provider":"Glaretum","version":"1.0","type":"link"}