{"product_id":"supresor-de-pico-clase-c-con-voltaje-de-operacion-277-480-vca-3-fases-200-ka","title":"Class C Surge Suppressor with Operating Voltage 277\/480 VAC, 3-Phase, 200 KA","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003c!-- Imagen principal --\u003e\u003cdiv style=\"width: 100%; margin-bottom: 30px;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KDALU\/76017-total_ground.jpg\" alt=\"\"\u003e\u003c\/div\u003e\n\n\u003c!-- Sección de descripción --\u003e\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003cp style=\"font-size: 15px; margin-bottom: 15px; color: inherit;\"\u003eSUPRECTOR class C transient suppressors are designed to provide the best protection for main electrical panels, especially those with critical loads.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 15px; margin-bottom: 15px; color: inherit;\"\u003eSUPRECTOR brand suppressors feature hybrid technology that includes varistors of different capacities to suit various protection needs. In addition, the varistors integrate a high-precision thermal fuse that opens the circuit in the event of an overcurrent, preventing flame emission and stopping the varistor from short-circuiting. They also offer modular protection for easy replacement, repair, and scalability.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 15px; margin-bottom: 15px; color: inherit;\"\u003eAnother strength of SUPRECTOR is the wave tracking circuit, which functions to filter the noise generated by transient voltage clipping.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Sección de aplicaciones --\u003e\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eAPPLICATIONS\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 15px; margin-bottom: 15px; color: inherit;\"\u003eClass C suppressors are designed to provide protection in main or distribution panels.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Sección de especificaciones --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eFEATURES\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e NEMA 4\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 30 x 20 x 12 cm\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 277\/480 VAC\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e 200 KA\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003ePhases:\u003c\/strong\u003e 3\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eWires:\u003c\/strong\u003e 5\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eProtection Modes\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eLine-Neutral (L-N)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eLine-Ground (L-G)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eNeutral-Ground (N-G)\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eLine-Line (L-L) (Upon Request)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Sección de estado de operación --\u003e\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eOPERATION DIAGNOSTICS\u003c\/h3\u003e\n\n\u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cspan style=\"color: #27ae60; font-weight: bold;\"\u003eGREEN\u003c\/span\u003e = PROTECTED\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cspan style=\"color: #c0392b; font-weight: bold;\"\u003eRED\u003c\/span\u003e = UNPROTECTED\u003c\/li\u003e\n\n\u003cli style=\"margin-bottom: 5px;\"\u003eLED(s) OFF = \u003cstrong\u003eDISCONNECTED\u003c\/strong\u003e. Replace the suppressor module after checking the line voltage and the installation diagram.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Sección de recomendación de uso --\u003e\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eUsage Recommendation\u003c\/h3\u003e\n\n\u003cdiv style=\"width: 100%; margin: 20px 0;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/SUPR2003FC\/76146-supresores_tabla_recomendacion_uso.png\" alt=\"\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Sección de selección de supresor --\u003e\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eHow to Select a Total Ground Class C Suppressor?\u003c\/h3\u003e\n\n\u003cdiv style=\"width: 100%; margin: 20px 0;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/SUPR2003FC\/76146-tabla_voltaje_c.png\" alt=\"\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"width: 100%; margin: 20px 0;\"\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/SUPR2003FC\/76146-supresor_medidad.png\" alt=\"\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Garantía --\u003e\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eWARRANTY\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 15px; color: inherit;\"\u003e5 years\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- Separador final --\u003e\u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e\n\n\n\u003c\/div\u003e","brand":"TOTAL GROUND","offers":[{"title":"Default Title","offer_id":62828387860639,"sku":"SUPR-200-3FC","price":28599.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/SUPR2003FC-p.png?v=1783712453","url":"https:\/\/store.glaretum.com\/en\/products\/supresor-de-pico-clase-c-con-voltaje-de-operacion-277-480-vca-3-fases-200-ka","provider":"Glaretum","version":"1.0","type":"link"}