{"product_id":"terminal-hospitalaria-empotrable-nx0015-controlador-ip-para-sistema-de-llamada-paciente-enfermera-voip-sip-poe-12-entradas-digitales-bus-rs485","title":"NX0015 Recessed Hospital Terminal \/ IP Controller for Nurse Call System \/ VoIP SIP \/ PoE \/ 12 Digital Inputs \/ RS485 Bus","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e\n\n\u003c!-- ========== HERO ========== --\u003e\u003cdiv style=\"position: relative; width: 100%; margin-bottom: 40px; border-radius: 12px; overflow: hidden;\"\u003e\n\n\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/imagenes_syscom\/AI\/agente\/ai_1783624314390_quvmn9.png\" alt=\"NX0015 Hospital Headboard Terminal\" style=\"width: 100%; height: auto; display: block;\"\u003e\u003cdiv style=\"position: absolute; bottom: 0; left: 0; right: 0; padding: 40px 30px; background: linear-gradient(transparent, rgba(11,26,48,0.85));\"\u003e\n\n\u003cp style=\"font-size: 13px; letter-spacing: 2px; text-transform: uppercase; color: #EBA833; margin: 0 0 8px 0;\"\u003eIBERNEX · NX0015 · Hospital Terminal\u003c\/p\u003e\n\n\u003ch2 style=\"font-size: 32px; font-weight: bold; color: #FFFFFF; margin: 0 0 10px 0; line-height: 1.2;\"\u003eThe silent core of hospital care.\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 16px; color: #FFFFFF; opacity: 0.9; margin: 0; max-width: 600px;\"\u003e12 digital inputs. VoIP SIP. PoE. All recessed in a 62 mm depth.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- ========== STATS RIBBON ========== --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 0; margin-bottom: 50px; border: 2px solid #0B1A30; border-radius: 12px; overflow: hidden; background-color: #0B1A30;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 150px; text-align: center; padding: 25px 15px; border-right: 1px solid rgba(235,168,51,0.3); border-bottom: 1px solid rgba(235,168,51,0.3);\"\u003e\n\n\u003cdiv style=\"font-size: 36px; font-weight: bold; color: #EBA833; line-height: 1;\"\u003e12\u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 12px; color: #FFFFFF; opacity: 0.8; margin-top: 5px; text-transform: uppercase; letter-spacing: 1px;\"\u003eDigital Inputs\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 150px; text-align: center; padding: 25px 15px; border-right: 1px solid rgba(235,168,51,0.3); border-bottom: 1px solid rgba(235,168,51,0.3);\"\u003e\n\n\u003cdiv style=\"font-size: 36px; font-weight: bold; color: #EBA833; line-height: 1;\"\u003eSIP\u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 12px; color: #FFFFFF; opacity: 0.8; margin-top: 5px; text-transform: uppercase; letter-spacing: 1px;\"\u003eVoIP + FXS\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 150px; text-align: center; padding: 25px 15px; border-right: 1px solid rgba(235,168,51,0.3); border-bottom: 1px solid rgba(235,168,51,0.3);\"\u003e\n\n\u003cdiv style=\"font-size: 36px; font-weight: bold; color: #EBA833; line-height: 1;\"\u003ePoE\u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 12px; color: #FFFFFF; opacity: 0.8; margin-top: 5px; text-transform: uppercase; letter-spacing: 1px;\"\u003eIEEE 802.3af\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 150px; text-align: center; padding: 25px 15px; border-right: 1px solid rgba(235,168,51,0.3); border-bottom: 1px solid rgba(235,168,51,0.3);\"\u003e\n\n\u003cdiv style=\"font-size: 36px; font-weight: bold; color: #EBA833; line-height: 1;\"\u003eRS485\u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 12px; color: #FFFFFF; opacity: 0.8; margin-top: 5px; text-transform: uppercase; letter-spacing: 1px;\"\u003ePeripheral Bus\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 150px; text-align: center; padding: 25px 15px; border-right: 1px solid rgba(235,168,51,0.3); border-bottom: 1px solid rgba(235,168,51,0.3);\"\u003e\n\n\u003cdiv style=\"font-size: 36px; font-weight: bold; color: #EBA833; line-height: 1;\"\u003e2\u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 12px; color: #FFFFFF; opacity: 0.8; margin-top: 5px; text-transform: uppercase; letter-spacing: 1px;\"\u003eEthernet Ports\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 150px; text-align: center; padding: 25px 15px; border-bottom: 1px solid rgba(235,168,51,0.3);\"\u003e\n\n\u003cdiv style=\"font-size: 36px; font-weight: bold; color: #EBA833; line-height: 1;\"\u003e62\u003c\/div\u003e\n\n\u003cdiv style=\"font-size: 12px; color: #FFFFFF; opacity: 0.8; margin-top: 5px; text-transform: uppercase; letter-spacing: 1px;\"\u003emm Depth\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- ========== PILAR 1: COMUNICACION ========== --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 50px; align-items: center;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 400px; min-width: 280px;\"\u003e\n\n\u003cp style=\"font-size: 13px; letter-spacing: 2px; text-transform: uppercase; color: #EBA833; margin: 0 0 8px 0;\"\u003eCommunication\u003c\/p\u003e\n\n\u003ch3 style=\"font-size: 26px; font-weight: bold; color: #0B1A30; margin: 0 0 15px 0; line-height: 1.3;\"\u003eClear voice. No noise. No complications.\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 15px; color: inherit; opacity: 0.9; line-height: 1.7;\"\u003eThe patient presses a button. The nurse listens. The call travels via VoIP SIP over the existing Ethernet network, with an integrated FXS port for analog extensions. No dedicated infrastructure needed: the hospital's network is enough. The NX0015 turns every room into a professional communication node.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 350px; min-width: 280px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/IBERNEX\/NX0015\/NX0015-FRENTE-p.PNG\" alt=\"NX0015 Front View\" style=\"max-width: 100%; height: auto; border-radius: 8px; border: 2px solid #0B1A30;\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- ========== PILAR 2: INTEGRACION ========== --\u003e\u003cdiv style=\"width: 100%; background-color: #0B1A30; padding: 40px 30px; border-radius: 12px; margin-bottom: 50px;\"\u003e\u003cdiv style=\"max-width: 800px; margin: 0 auto;\"\u003e\n\n\u003cp style=\"font-size: 13px; letter-spacing: 2px; text-transform: uppercase; color: #EBA833; margin: 0 0 8px 0;\"\u003eIntegration\u003c\/p\u003e\n\n\u003ch3 style=\"font-size: 26px; font-weight: bold; color: #FFFFFF; margin: 0 0 15px 0; line-height: 1.3;\"\u003e12 inputs. One single controller.\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 15px; color: #FFFFFF; opacity: 0.9; line-height: 1.7;\"\u003eCall buttons, bathroom pull cords, presence sensors, code blue buttons. The NX0015 receives up to 12 digital signals via pluggable terminals and manages them centrally. The RS485 bus connects expansion modules — RFID readers, button panels, audio amplifiers — without saturating the IP network.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\n\n\u003c!-- ========== PILAR 3: ALIMENTACION ========== --\u003e\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 50px; align-items: center;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 350px; min-width: 280px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/scorrea\/A\/IBERNEX\/I\/nx0114ca_b.JPG\" alt=\"NX0015 Installation\" style=\"max-width: 100%; height: auto; border-radius: 8px; border: 2px solid #0B1A30;\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 400px; min-width: 280px;\"\u003e\n\n\u003cp style=\"font-size: 13px; letter-spacing: 2px; text-transform: uppercase; color: #EBA833; margin: 0 0 8px 0;\"\u003ePower Supply\u003c\/p\u003e\n\n\u003ch3 style=\"font-size: 26px; font-weight: bold; color: #0B1A30; margin: 0 0 15px 0; line-height: 1.3;\"\u003eOne cable. Data and power.\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 15px; color: inherit; opacity: 0.9; line-height: 1.7;\"\u003ePoE IEEE 802.3af: a single Ethernet cable powers the terminal and transmits data. If PoE infrastructure is not available, the 12 VDC auxiliary power supply guarantees continuous operation. Two Ethernet ports allow for redundant connectivity or network segmentation. Consumption of only 8.5 W via PoE.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- ========== TOPOLOGIA ========== --\u003e\u003cdiv style=\"width: 100%; margin-bottom: 50px; text-align: center;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; font-weight: bold; color: #0B1A30; margin: 0 0 10px 0;\"\u003eIP Connection Topology\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 14px; color: inherit; opacity: 0.7; margin: 0 0 20px 0;\"\u003eAll room terminals, nurse consoles, and doctor stations connect via Ethernet network to the database.\u003c\/p\u003e\n\n\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/scorrea\/A\/IBERNEX\/I\/topologia.png\" alt=\"IP Connection Topology\" style=\"width: 100%; max-width: 900px; height: auto; border-radius: 8px; border: 2px solid #0B1A30;\"\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- ========== APLICACIONES ========== --\u003e\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\n\u003cp style=\"font-size: 13px; letter-spacing: 2px; text-transform: uppercase; color: #EBA833; margin: 0 0 8px 0; text-align: center;\"\u003eApplications\u003c\/p\u003e\n\n\u003ch3 style=\"font-size: 22px; font-weight: bold; color: #0B1A30; margin: 0 0 25px 0; text-align: center;\"\u003eWhere care cannot wait.\u003c\/h3\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 220px; min-width: 200px; border: 1px solid rgba(11,26,48,0.3); border-radius: 10px; padding: 20px; border-top: 3px solid #EBA833;\"\u003e\n\n\u003ch4 style=\"font-size: 16px; font-weight: bold; color: #0B1A30; margin: 0 0 8px 0;\"\u003eHospitals\u003c\/h4\u003e\n\n\u003cp style=\"font-size: 13px; color: inherit; opacity: 0.8; margin: 0;\"\u003ePatient rooms with nurse call, code blue, and assisted bathroom monitoring.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 220px; min-width: 200px; border: 1px solid rgba(11,26,48,0.3); border-radius: 10px; padding: 20px; border-top: 3px solid #EBA833;\"\u003e\n\n\u003ch4 style=\"font-size: 16px; font-weight: bold; color: #0B1A30; margin: 0 0 8px 0;\"\u003eClinics\u003c\/h4\u003e\n\n\u003cp style=\"font-size: 13px; color: inherit; opacity: 0.8; margin: 0;\"\u003eConsultation rooms and recovery areas with direct communication to medical staff.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 220px; min-width: 200px; border: 1px solid rgba(11,26,48,0.3); border-radius: 10px; padding: 20px; border-top: 3px solid #EBA833;\"\u003e\n\n\u003ch4 style=\"font-size: 16px; font-weight: bold; color: #0B1A30; margin: 0 0 8px 0;\"\u003eResidences\u003c\/h4\u003e\n\n\u003cp style=\"font-size: 13px; color: inherit; opacity: 0.8; margin: 0;\"\u003eGeriatric care centers with immediate assistance and continuous supervision.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 220px; min-width: 200px; border: 1px solid rgba(11,26,48,0.3); border-radius: 10px; padding: 20px; border-top: 3px solid #EBA833;\"\u003e\n\n\u003ch4 style=\"font-size: 16px; font-weight: bold; color: #0B1A30; margin: 0 0 8px 0;\"\u003eLaboratories\u003c\/h4\u003e\n\n\u003cp style=\"font-size: 13px; color: inherit; opacity: 0.8; margin: 0;\"\u003eIsolation areas and clean rooms with integrated emergency signaling.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- ========== EJEMPLOS DE USO ========== --\u003e\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\n\u003ch3 style=\"font-size: 22px; font-weight: bold; color: #0B1A30; margin: 0 0 10px 0; text-align: center;\"\u003eInstallation example\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 14px; color: inherit; opacity: 0.7; margin: 0 0 20px 0; text-align: center;\"\u003ePeripherals connect directly to the room terminal.\u003c\/p\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 15px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 400px; min-width: 280px;\"\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/scorrea\/A\/IBERNEX\/I\/ejemplo2.JPG\" alt=\"Usage example 1\" style=\"width: 100%; height: auto; border-radius: 8px; border: 2px solid #0B1A30;\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 400px; min-width: 280px;\"\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/scorrea\/A\/IBERNEX\/I\/ejemplo2b.JPG\" alt=\"Usage example 2\" style=\"width: 100%; height: auto; border-radius: 8px; border: 2px solid #0B1A30;\"\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- ========== ESPECIFICACIONES ========== --\u003e\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\n\u003cp style=\"font-size: 13px; letter-spacing: 2px; text-transform: uppercase; color: #EBA833; margin: 0 0 8px 0; text-align: center;\"\u003eSpecifications\u003c\/p\u003e\n\n\u003ch3 style=\"font-size: 22px; font-weight: bold; color: #0B1A30; margin: 0 0 25px 0; text-align: center;\"\u003eEvery detail, documented.\u003c\/h3\u003e\n\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px;\"\u003e\n\n\u003cdiv style=\"flex: 1 1 280px; min-width: 250px; border: 1px solid rgba(11,26,48,0.3); border-radius: 10px; overflow: hidden;\"\u003e\n\n\u003cdiv style=\"padding: 15px 20px; border-bottom: 1px solid rgba(11,26,48,0.15); font-weight: bold; font-size: 16px; color: #FFFFFF; background-color: #0B1A30;\"\u003eCommunication\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px 20px;\"\u003e\u003cdl style=\"margin: 0; font-size: 14px; color: inherit;\"\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eVoIP Protocol\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003eSIP\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eFXS Port\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003eIntegrated (analog extension)\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eEthernet Ports\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003e2 (Port 1 with PoE)\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eExpansion Bus\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003eRS485\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eSoftware\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003eHelpnex compatible\u003c\/dd\u003e\n\n\n\u003c\/dl\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 280px; min-width: 250px; border: 1px solid rgba(11,26,48,0.3); border-radius: 10px; overflow: hidden;\"\u003e\n\n\u003cdiv style=\"padding: 15px 20px; border-bottom: 1px solid rgba(11,26,48,0.15); font-weight: bold; font-size: 16px; color: #FFFFFF; background-color: #0B1A30;\"\u003eInputs \/ Outputs\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px 20px;\"\u003e\u003cdl style=\"margin: 0; font-size: 14px; color: inherit;\"\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eDigital Inputs\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003e12 (pluggable terminals)\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eAudio\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003eConnectors for speaker and microphone\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eCompatible peripherals\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003eNX0034, NX0037, NX0038, NX0062, NX0067, NX0080, NX0086A, NX0102, NX0101, NX0110, NX0176, NX0193, NX0195, NX0392, NX0394, NX0397R\u003c\/dd\u003e\n\n\n\u003c\/dl\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"flex: 1 1 280px; min-width: 250px; border: 1px solid rgba(11,26,48,0.3); border-radius: 10px; overflow: hidden;\"\u003e\n\n\u003cdiv style=\"padding: 15px 20px; border-bottom: 1px solid rgba(11,26,48,0.15); font-weight: bold; font-size: 16px; color: #FFFFFF; background-color: #0B1A30;\"\u003eElectrical and Physical\u003c\/div\u003e\n\n\u003cdiv style=\"padding: 15px 20px;\"\u003e\u003cdl style=\"margin: 0; font-size: 14px; color: inherit;\"\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003ePower Supply\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003e12 VDC \/ PoE IEEE 802.3af\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eCurrent\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003e620 mA at 12 VDC (8.5 W PoE)\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eDimensions\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003e267 x 164 x 62 mm\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eWeight\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003e0.2 kg\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eMounting\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003eRecessed in hospital headboard\u003c\/dd\u003e\n\n\u003cdt style=\"font-weight: bold; margin-top: 10px; color: #0B1A30;\"\u003eWarranty\u003c\/dt\u003e\n\n\u003cdd style=\"margin: 2px 0 0 0; opacity: 0.8;\"\u003e3 years\u003c\/dd\u003e\n\n\n\u003c\/dl\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003c!-- ========== CIERRE ========== --\u003e\u003cdiv style=\"text-align: center; padding: 30px 20px; border: 2px solid #0B1A30; border-radius: 12px; background-color: rgba(11,26,48,0.04);\"\u003e\n\n\u003cp style=\"font-size: 13px; letter-spacing: 2px; text-transform: uppercase; color: #EBA833; margin: 0 0 8px 0;\"\u003eCompatibility and Support\u003c\/p\u003e\n\n\u003ch3 style=\"font-size: 22px; font-weight: bold; color: #0B1A30; margin: 0 0 15px 0;\"\u003eIBERNEX Ecosystem. Helpnex Software. Mobile app available.\u003c\/h3\u003e\n\n\u003cp style=\"font-size: 14px; color: inherit; opacity: 0.8; margin: 0 0 15px 0; max-width: 600px; display: inline-block;\"\u003eThe NX0015 operates autonomously or integrated with Helpnex software for centralized call management. Compatible with the Helpnex mobile application for real-time notifications to medical staff.\u003c\/p\u003e\n\n\u003cp style=\"font-size: 13px; color: #0B1A30; margin: 15px 0 0 0; padding: 10px; background-color: rgba(235,168,51,0.15); border-radius: 6px; border-left: 4px solid #EBA833; display: inline-block;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Certification required for installation and to request technical support.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"IBERNEX","offers":[{"title":"Default Title","offer_id":62836766507167,"sku":"NX0015","price":12399.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/NX0015-p.png?v=1784843336","url":"https:\/\/store.glaretum.com\/en\/products\/terminal-hospitalaria-empotrable-nx0015-controlador-ip-para-sistema-de-llamada-paciente-enfermera-voip-sip-poe-12-entradas-digitales-bus-rs485","provider":"Glaretum","version":"1.0","type":"link"}