{"product_id":"tramo-de-torre-arriostrada-de-3m-x-35cm-galvanizado-por-electrolisis-hasta-45-m-de-elevacion-zonas-secas","title":"3m x 35cm Guyed Tower Section, Electrolytic Galvanized, Up to 45m Elevation. Dry Zones.","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"width: 100%; margin-bottom: 30px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/STZ30\/31572-imagen.png\" alt=\"\"\u003e \u003c\/div\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eHighlights\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under standard: \u003cstrong style=\"color: inherit;\"\u003eISO 9001:2015\u003c\/strong\u003e\n\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEach section is manufactured using numerical control machinery\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIncludes hardware for installation\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRecommended for Dry Zones (35% average humidity or less) and free of corrosive agents such as salt spray or other chemicals that accelerate the oxidation process\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eComplies with electrolytic galvanizing standard: \u003cstrong style=\"color: inherit;\"\u003eASTMB-633\u003c\/strong\u003e\n\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePhysical Characteristics\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eMaximum Load:\u003c\/strong\u003e 350 kg\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eMaximum Height:\u003c\/strong\u003e 45 m (15 sections)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eWind Resistance:\u003c\/strong\u003e 200 km\/h\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eMaterial:\u003c\/strong\u003e 1 1\/4\" industrial pipe (14 Gauge)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eZig-zag Bracing:\u003c\/strong\u003e 5\/16\" round bar\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eNipple:\u003c\/strong\u003e 12 cm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eFace width:\u003c\/strong\u003e 35 cm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eWeight:\u003c\/strong\u003e 20.75 kg\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eDimensions:\u003c\/strong\u003e 3 m Length\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eStructure material:\u003c\/strong\u003e Steel (A-36)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong style=\"color: inherit;\"\u003eAnticorrosive protection:\u003c\/strong\u003e Electrolytic galvanizing (ASTMB-633)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eApplication\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePoint-to-Point systems\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePoint-to-Multipoint systems\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCellular signal amplification\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLightning rod systems\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eBase repeater radios\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMonitoring points\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLighting\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEmergency audible signaling\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnd more\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 20px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eImportant Technical Notes\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEnsure that the installation is performed by a trained professional\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan to check guy wire tension and tighten hardware\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe stated weight is for equipment without accessories and without packaging\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eTowers can be purchased in complete kits \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2021\/07\/27\/a827a\/KITS%20DE%20TORRES.pdf\" target=\"_blank\" rel=\"noopener\"\u003eVIEW TOWER KITS\u003c\/a\u003e\n\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 20px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eWarning\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eElectrolytic galvanizing is not recommended for humid zones, salt spray environments, and\/or corrosive areas such as coasts, dams, or industrial parks with gas discharge \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/GALVANIZADO%20EN%20M%C3%89XICO%20(1).png\" target=\"_blank\" rel=\"noopener\"\u003eVIEW AREA MAP\u003c\/a\u003e\n\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in accordance with (at minimum) CFE D8500-02 specifications (7 symmetrical orange and white alternating stripes, starting and ending with orange)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMust include night lighting, with at least two beacons, one in the middle and one at the top\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLocal municipal regulations must be consulted to ensure a correct and legal tower installation\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eWe strongly recommend following the guy wire installation guidelines at all times: \u003ca style=\"color: inherit; text-decoration: underline;\" href=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" target=\"_blank\" rel=\"noopener\"\u003eVIEW GUY WIRE INSTALLATION DIAGRAM\u003c\/a\u003e\n\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 20px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eInstallation Videos\u003c\/h3\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 300px;\"\u003e \u003cdiv style=\"position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden;\"\u003e \u003ciframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: none;\" src=\"https:\/\/www.youtube.com\/embed\/MR65qhmHJwE\" allowfullscreen\u003e\u003c\/iframe\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 300px;\"\u003e \u003cdiv style=\"position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden;\"\u003e \u003ciframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: none;\" src=\"https:\/\/www.youtube.com\/embed\/oSMsW5y3ayk\" allowfullscreen\u003e\u003c\/iframe\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828319834271,"sku":"STZ-35","price":3299.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/STZ35-p.png?v=1783708055","url":"https:\/\/store.glaretum.com\/en\/products\/tramo-de-torre-arriostrada-de-3m-x-35cm-galvanizado-por-electrolisis-hasta-45-m-de-elevacion-zonas-secas","provider":"Glaretum","version":"1.0","type":"link"}