{"product_id":"tramo-de-torre-arriostrada-de-3m-x-45cm-galvanizado-por-electrolisis-hasta-60-m-de-elevacion-zonas-secas","title":"3m x 45cm Guyed Tower Section, Electrolytic Galvanized, Up to 60m Elevation. Dry Zones.","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cp style=\"margin: 0; padding: 0; height: 1px;\"\u003e\u003c\/p\u003e \u003c!-- Main image --\u003e \u003cdiv style=\"width: 100%; margin-bottom: 30px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150,150,150,0.3); border-radius: 8px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/STZ30\/31572-imagen.png\" alt=\"\"\u003e \u003c\/div\u003e \u003cp style=\"margin: 0; padding: 0; height: 1px;\"\u003e\u003c\/p\u003e \u003c!-- Features section --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eHighlights\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eProduct manufactured under standard: \u003cstrong style=\"color: #e74c3c;\"\u003eISO 9001:2015\u003c\/strong\u003e\n\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEach section is manufactured using CNC machinery\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\u003cstrong style=\"text-decoration: underline; color: inherit;\"\u003eIncludes hardware for installation\u003c\/strong\u003e\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eRecommended for dry areas (35% average humidity or less) free of corrosive agents such as salt air or other chemicals that accelerate the oxidation process\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIn accordance with electrolytic galvanizing standard: \u003cstrong\u003eASTMB-633\u003c\/strong\u003e\n\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003ePhysical Characteristics\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaximum Load:\u003c\/strong\u003e 500 kg\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaximum Height:\u003c\/strong\u003e 60 m (20 sections)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eWind Resistance:\u003c\/strong\u003e 200 km\/h\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e 1 1\/4\" Industrial pipe (14 ga.)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eLattice (Zig-zag):\u003c\/strong\u003e 3\/8\" round\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eNipple:\u003c\/strong\u003e 12 cm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eFace width:\u003c\/strong\u003e 45 cm\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 26 kg\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 3 m length\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eStructure material:\u003c\/strong\u003e Steel (A-36)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003e\n\n\u003cstrong\u003eAnti-corrosion protection:\u003c\/strong\u003e Electrolytic galvanizing (ASTMB-633)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eApplication\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePoint-to-Point systems\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003ePoint-to-Multipoint systems\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eCellular signal amplification\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLightning rod systems\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eBase repeater radios\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eMonitoring points\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLighting\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEmergency audio signaling\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eAnd more\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Technical notes section --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eKey Technical Notes\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eEnsure installation is performed by a trained professional\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eSchedule a maintenance plan to check guy wire tension and tighten hardware\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eDo not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eA stress study must be conducted when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe stated weight is for equipment without accessories and without packaging\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eTowers can be purchased in complete kits \u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2021\/07\/27\/a827a\/KITS%20DE%20TORRES.pdf\" style=\"color: #005cb9; text-decoration: none; font-weight: bold;\" target=\"_blank\" rel=\"noopener\"\u003eVIEW TOWER KITS\u003c\/a\u003e\n\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Warnings section --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eWarning\u003c\/h3\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 5px; color: #ed0808;\"\u003eElectrolytic galvanizing is not recommended for humid zones, salt air, and\/or corrosive environments such as coastal areas, dams, or industrial parks with gas discharge \u003ca href=\"http:\/\/ftp3.syscom.mx\/usuarios\/dcarreon\/TORRES\/GALVANIZADO%20EN%20M%C3%89XICO%20(1).png\" style=\"color: #005cb9; text-decoration: none; font-weight: bold;\" target=\"_blank\" rel=\"noopener\"\u003eVIEW AREA MAP\u003c\/a\u003e\n\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eThe tower must be painted in accordance with (at minimum) CFE D8500-02 specification (7 symmetrical orange and white alternating stripes, starting and ending in orange)\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eIt must include night lighting, at least two beacons: one at the midpoint and one at the top\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eLocal municipal regulations must be consulted to ensure correct and legal tower installation\u003c\/li\u003e \u003cli style=\"margin-bottom: 5px;\"\u003eWe recommend following the guy wire installation recommendations at all times: \u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/KTZ30G030\/75810-recomendaci%C3%B3n_de_instalaci%C3%B3n_de_retenida_2.0.png\" style=\"color: #005cb9; text-decoration: none; font-weight: bold;\" target=\"_blank\" rel=\"noopener\"\u003eVIEW GUY WIRE INSTALLATION DIAGRAM\u003c\/a\u003e\n\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Videos section --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-bottom: 30px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003cdiv style=\"position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden;\"\u003e \u003ciframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: none;\" src=\"https:\/\/www.youtube.com\/embed\/MR65qhmHJwE\" allowfullscreen\u003e\u003c\/iframe\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 280px;\"\u003e \u003cdiv style=\"position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden;\"\u003e \u003ciframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: none;\" src=\"https:\/\/www.youtube.com\/embed\/oSMsW5y3ayk\" allowfullscreen\u003e\u003c\/iframe\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin: 0; padding: 0; height: 1px;\"\u003e\u003c\/p\u003e \u003c\/div\u003e","brand":"SYSCOM TOWERS","offers":[{"title":"Default Title","offer_id":62828320063647,"sku":"STZ-45","price":4199.0,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/STZ45-p.png?v=1783708065","url":"https:\/\/store.glaretum.com\/en\/products\/tramo-de-torre-arriostrada-de-3m-x-45cm-galvanizado-por-electrolisis-hasta-60-m-de-elevacion-zonas-secas","provider":"Glaretum","version":"1.0","type":"link"}