{"product_id":"ups-de-20-kva-online-doble-conversion-3f-200-240-vac-de-entrada-200-240-vac-de-salida-terminal-hardwired-onda-senoidal-pura-no-incluye-banco-de-baterias","title":"20 KVA UPS, Online Double Conversion, 3P 200 - 240 Vac Input, 200 - 240 Vac Output, Hardwired Terminal, Pure Sine Wave (Battery bank not included).","description":"\u003cp\u003e\u003c\/p\u003e\u003cdiv style=\"width: 100%; max-width: 1200px; margin: 0 auto; font-family: sans-serif; line-height: 1.6; color: inherit; background-color: transparent;\"\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 24px; margin-top: 0; color: inherit; opacity: 0.95;\"\u003eUPS LP20KYDC – High-Efficiency Three-Phase Backup System (20 kVA \/ 20 kW)\u003c\/h3\u003e \u003cp style=\"font-size: 16px; margin: 10px 0 0; color: inherit; opacity: 0.8;\"\u003eLP10-100KYDC Series | Transformerless Online UPS | Online Double Conversion\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"margin-bottom: 30px; font-size: 15px; color: inherit;\"\u003e \u003cp\u003eThe LP20KYDC model is a transformerless three-phase UPS, designed with online double-conversion technology, which provides stable and continuous electrical protection for critical applications. With a 20 kVA \/ 20 kW capacity and a 1.0 output power factor, it is an ideal solution for data centers, telecommunications systems, industrial environments, and mission-critical applications.\u003c\/p\u003e \u003cp style=\"font-size: 16px; font-weight: bold; color: inherit; background-color: rgba(255, 255, 255, 0.05); padding: 15px; border-left: 4px solid rgba(255, 255, 255, 0.3); margin: 20px 0;\"\u003eEquipment does not include external battery bank or internal batteries; they must be quoted separately. Consult with the engineering department for the appropriate model and quantity.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch4 style=\"font-size: 20px; border-bottom: 2px solid rgba(150,150,150,0.3); padding-bottom: 8px; margin-top: 0; color: inherit; opacity: 0.85;\"\u003eMain Features:\u003c\/h4\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 20px; margin-top: 20px;\"\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 250px;\"\u003e \u003ch5 style=\"font-size: 16px; font-weight: bold; margin-top: 0; color: inherit; opacity: 0.9;\"\u003eSuperior energy performance:\u003c\/h5\u003e \u003cul style=\"padding-left: 20px; margin: 10px 0; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eEfficiency up to 94%\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eThree-phase input and output (3Ph+N+PE)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eInput power factor ≥0.99 and THDi ≤3%\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 250px;\"\u003e \u003ch5 style=\"font-size: 16px; font-weight: bold; margin-top: 0; color: inherit; opacity: 0.9;\"\u003eHigh reliability:\u003c\/h5\u003e \u003cul style=\"padding-left: 20px; margin: 10px 0; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e132-275 Vac input range\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eUnbalanced, inductive, or capacitive loads\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e0 ms transfer time\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 250px;\"\u003e \u003ch5 style=\"font-size: 16px; font-weight: bold; margin-top: 0; color: inherit; opacity: 0.9;\"\u003eScalability:\u003c\/h5\u003e \u003cul style=\"padding-left: 20px; margin: 10px 0; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eUp to 6 units in parallel\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eLBS function for synchronization\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 250px;\"\u003e \u003ch5 style=\"font-size: 16px; font-weight: bold; margin-top: 0; color: inherit; opacity: 0.9;\"\u003eIntelligent management:\u003c\/h5\u003e \u003cul style=\"padding-left: 20px; margin: 10px 0; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eUSB, RS232, RS485, SNMP, dry contact\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003ePower Walk-In for generators\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch4 style=\"font-size: 20px; border-bottom: 2px solid rgba(150,150,150,0.3); padding-bottom: 8px; margin-top: 0; color: inherit; opacity: 0.85;\"\u003eTechnical Specifications:\u003c\/h4\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 30px; margin-top: 20px;\"\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 250px;\"\u003e \u003ch5 style=\"font-size: 16px; font-weight: bold; margin-top: 0; color: inherit; opacity: 0.9;\"\u003eInput:\u003c\/h5\u003e \u003cul style=\"padding-left: 20px; margin: 10px 0; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e208\/120 Vac or 220\/127 Vac\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e132-275 Vac (100% load from 176 Vac)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e40-70 Hz, Power factor ≥0.99, THDi ≤3%\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 250px;\"\u003e \u003ch5 style=\"font-size: 16px; font-weight: bold; margin-top: 0; color: inherit; opacity: 0.9;\"\u003eOutput:\u003c\/h5\u003e \u003cul style=\"padding-left: 20px; margin: 10px 0; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e208\/120 Vac or 220\/127 Vac, ±1%\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003ePower factor 1.0, THDv ≤2%\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eOverload: 110% 60min, 125% 10min, 150% 1min\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 250px;\"\u003e \u003ch5 style=\"font-size: 16px; font-weight: bold; margin-top: 0; color: inherit; opacity: 0.9;\"\u003eBatteries:\u003c\/h5\u003e \u003cul style=\"padding-left: 20px; margin: 10px 0; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e16 to 26 batteries per group\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e±192 to ±312 Vdc, Charging current 40 A\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 300px; min-width: 250px;\"\u003e \u003ch5 style=\"font-size: 16px; font-weight: bold; margin-top: 0; color: inherit; opacity: 0.9;\"\u003ePhysical:\u003c\/h5\u003e \u003cul style=\"padding-left: 20px; margin: 10px 0; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e400×935×1065mm, 150 kg\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e0-40°C, 0-95% humidity, less than 66 dB\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eUL 1778, CSA, FCC, Energy Star 2.0\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"margin-bottom: 30px; padding: 20px; border-left: 4px solid rgba(255, 255, 255, 0.3); background-color: rgba(255, 255, 255, 0.05);\"\u003e \u003ch5 style=\"font-size: 16px; font-weight: bold; margin-top: 0; margin-bottom: 15px; color: inherit; opacity: 0.9;\"\u003eNOTE:\u003c\/h5\u003e \u003cul style=\"padding-left: 20px; margin: 0; list-style-type: disc; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eInternal batteries not included\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eExternal batteries required\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eTower type, not rack-mountable\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eConsider installation accessories\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003chr style=\"border: 0; border-top: 1px solid rgba(150, 150, 150, 0.3); margin: 30px 0;\"\u003e \u003c!-- ========== SPARE PARTS ========== --\u003e \u003cdiv style=\"margin-bottom: 30px;\"\u003e \u003ch3 style=\"font-size: 22px; border-bottom: 2px solid currentColor; padding-bottom: 5px; margin-top: 0; color: inherit; opacity: 0.8;\"\u003eSpare Parts\u003c\/h3\u003e \u003cp style=\"font-size: 15px; color: inherit; margin-bottom: 15px;\"\u003eOriginal spare parts available for this model:\u003c\/p\u003e \u003cul style=\"padding-left: 20px; font-size: 15px; color: inherit;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\n\u003ca href=\"https:\/\/www.syscom.mx\/products?query=PWRLP20KYDC\" style=\"color: inherit; text-decoration: underline; font-weight: 500;\"\u003ePWRLP20KYDC\u003c\/a\u003e — Replacement Power Board for LP20KYDC UPS\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"LINKEDPRO BY EPCOM","offers":[{"title":"Default Title","offer_id":62837049458847,"sku":"LP20KYDC","price":108899.0,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0395\/9055\/9903\/files\/LP20KYDC-p.png?v=1784912355","url":"https:\/\/store.glaretum.com\/en\/products\/ups-de-20-kva-online-doble-conversion-3f-200-240-vac-de-entrada-200-240-vac-de-salida-terminal-hardwired-onda-senoidal-pura-no-incluye-banco-de-baterias","provider":"Glaretum","version":"1.0","type":"link"}