3m x 35cm Guyed Tower Section, Electrolytic Galvanized, Up to 45m Elevation. Dry Zones.
- $ 3,299.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: STZ-35
Highlights Product manufactured under standard: ISO 9001:2015 Each section is manufactured using numerical control machinery Includes hardware for installation Recommended for Dry Zones (35% average humidity or less) and free...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:STZ-35 , supplier:Syscom , syscom
Highlights
- Product manufactured under standard: ISO 9001:2015
- Each section is manufactured using numerical control machinery
- Includes hardware for installation
- Recommended for Dry Zones (35% average humidity or less) and free of corrosive agents such as salt spray or other chemicals that accelerate the oxidation process
- Complies with electrolytic galvanizing standard: ASTMB-633
Physical Characteristics
- Maximum Load: 350 kg
- Maximum Height: 45 m (15 sections)
- Wind Resistance: 200 km/h
- Material: 1 1/4" industrial pipe (14 Gauge)
- Zig-zag Bracing: 5/16" round bar
- Nipple: 12 cm
- Face width: 35 cm
- Weight: 20.75 kg
- Dimensions: 3 m Length
- Structure material: Steel (A-36)
- Anticorrosive protection: Electrolytic galvanizing (ASTMB-633)
Application
- Point-to-Point systems
- Point-to-Multipoint systems
- Cellular signal amplification
- Lightning rod systems
- Base repeater radios
- Monitoring points
- Lighting
- Emergency audible signaling
- And more
Important Technical Notes
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts
- A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The stated weight is for equipment without accessories and without packaging
- Towers can be purchased in complete kits VIEW TOWER KITS
Warning
- Electrolytic galvanizing is not recommended for humid zones, salt spray environments, and/or corrosive areas such as coasts, dams, or industrial parks with gas discharge VIEW AREA MAP
- The tower must be painted in accordance with (at minimum) CFE D8500-02 specifications (7 symmetrical orange and white alternating stripes, starting and ending with orange)
- Must include night lighting, with at least two beacons, one in the middle and one at the top
- Local municipal regulations must be consulted to ensure a correct and legal tower installation
- We strongly recommend following the guy wire installation guidelines at all times: VIEW GUY WIRE INSTALLATION DIAGRAM