4-Inch Base / For Notifier, Farenhyt, Silent Knight, and Fire-Lite detectors / White Color

  • $ 499.00
  • Brand: SYSTEM SENSOR
  • Availability: In stock
  • SKU: B501-WHITE

General Features Base diameter: 4.0' (10.2 cm) Base height: 0.74' (18.8 mm) Compact and professional design High-quality resistant material Color: White Compatible with Notifier, Farenhyt, Silent Knight, and Fire-Lite detectors...

Tags: categoria:Detección de Fuego , marca:SYSTEM SENSOR , proveedor:Syscom , sku:B501-WHITE , supplier:Syscom , syscom , Tecnología Y Electrónica

General Features

  • Base diameter: 4.0' (10.2 cm)
  • Base height: 0.74' (18.8 mm)
  • Compact and professional design
  • High-quality resistant material
  • Color: White
  • Compatible with Notifier, Farenhyt, Silent Knight, and Fire-Lite detectors

Electrical Specifications

  • Operating voltage: 15 to 32 VDC
  • Standby current: 150 µA
  • Standards: UL268, ULC S529
  • Terminals: + and -, and connections for remote annunciator

Installation Features

  • Direct mounting on 4' square boxes with plaster ring
  • Compatibility with 3½' octagonal, 50 mm, 60 mm, and 70 mm centers
  • Includes space for recording zone, address, and detector type
  • For intelligent systems with screw terminals for power and remote annunciator connections

Security Features

  • Includes tamper-resistance feature
  • Requires tool to remove detector
  • Do not use the tamper-resistance feature if the removal tool is required
  • Can be deactivated by breaking and removing the plastic lever
Applications
  • Intelligent detection systems
  • Fire alarm systems
  • Systems with connection supervision requirements
Installation Requirements
  • Verify continuity and correct polarity before installing
  • Use wire gauge no smaller than 18 AWG (0.823 mm²)
  • Up to 12 AWG (3.31 mm²) can be used with the base
  • Comply with applicable local electrical codes
Warranty

3-year limited warranty against defects in materials and workmanship under normal conditions of use and service.


Electrical Connections

  • Terminal 1: Power (-), Remote annunciator connection (-)
  • Terminal 2: Power (+)
  • Terminal 3: Remote annunciator connection (+)

Important Considerations

  • Use only with ULC-listed detector heads for proper system operation
  • The detector must be tested and maintained regularly following NFPA 72 or CAN/ULC S536 standards
  • The detector must be cleaned at least once a year
  • It is not acceptable to have three stripped wires under the same terminal unless they are separated by a washer