1
/
of
1
INDEX
Chemical Anchor Capsule 16X125MM
Chemical Anchor Capsule 16X125MM
Regular price
$ 99.00
Regular price
Sale price
$ 99.00
Taxes included.
Shipping calculated at checkout.
Quantity
Couldn't load pickup availability
Vendido por Glaretum, Proveedor de Servicio Autorizado Apple
Paga con tarjeta, Apple Pay o PayPal
¿Dudas? Escríbenos por WhatsApp o llama al 800 461 0096
Key features
- Easy installation in non-cracked concrete
- Temperature range -40°C to +80°C (max. +50°C long-term)
- Supports medium-high static or quasi-static loads
- Available in zinc-plated steel, A2 and A4 stainless steel
- Compatibility with approved M8-M24 studs
Technical information
- Type: Chemical capsule anchor
- Base material: Non-cracked concrete C20/25
- Approval: ETA 08/0350 option 8
- Resin: Epoxy acrylate with quartz and catalyst
- Anchor depth: 125 mm
- Capsule diameter: 17 mm
- Capsule length: 95 mm
- Tightening torque: 80 Nm
- Drill hole diameter: 18 mm
- Minimum base material depth: 160 mm
Compatibility
- Compatible diameters: M16
- Stud types: Zinc-plated, stainless A2 and A4
- Stud classes: 5.8, 8.8, A4-70, A4-80
- Installation conditions: Dry or wet holes
- Environments: Indoor and outdoor
Tensile loads
- Non-cracked concrete: 39 kN
- Steel class 5.8: 31.2 kN
- Steel class 8.8: 50.4 kN
- Stainless A4-70: 35.3 kN
- Stainless A4-80: 46.6 kN
Shear loads
- Non-cracked concrete: 19.0 kN
- Steel class 5.8: 31.2 kN
- Steel class 8.8: 50.4 kN
- Stainless A4-70: 35.3 kN
- Stainless A4-80: 46.6 kN
Critical distances
- Between anchors: 250 mm
- To edge: 125 mm
- Min. between anchors: 65 mm
- Min. to edge: 65 mm
Applications
- Fixing machinery and elements with vibrations
- Structural applications in non-cracked concrete
- Not suitable for overhead installation
- Compatible with indoor and outdoor installations
Certifications
- Approval ETA 08/0350 option 8
- Certificate EVCP 1109-BPR-0044
- ETAG 001-5
Materials
- Capsule: Glass ampoule with epoxy acrylate resin
- Studs: Zinc-plated steel, stainless A2-70 and A4-70
- Washer: DIN 125 zinc-plated, A2-70 or A4-70
- Nut: DIN 934, zinc-plated, A2-70 or A4-70
Installation conditions
- Installation temperature: -40°C to +80°C
- Effective depth: 95 mm
- Minimum distance to edge: 65 mm
- Minimum distance between anchors: 65 mm
- Requires percussion drill and 18 mm drill bits
- Requires blow-out pump and cleaning brush
Tensile resistance
- Non-cracked concrete: 39 kN
- Steel class 5.8: 31.2 kN
- Steel class 8.8: 50.4 kN
- Stainless A4-70: 35.3 kN
- Stainless A4-80: 46.6 kN
Shear resistance
- Non-cracked concrete: 19.0 kN
- Steel class 5.8: 31.2 kN
- Steel class 8.8: 50.4 kN
- Stainless A4-70: 35.3 kN
- Stainless A4-80: 46.6 kN
Important notes
- Not suitable for overhead installation
- Not recommended for dynamic or eccentric loads
- Requires specific installation tools
- Must be installed in a clean and dry hole (according to standard)
- Actual resistance depends on distance to edge and between anchors
Technical references
- Approval ETA 08/0350 (ETAG 001-5) option 8
- Simplified calculation method according to ETAG 001 Annex C
- For precise calculations, use INDEXcal (INDEX calculation software)