Wishlist

Airlock Controller with electric locks for 2 Doors / 12VDC Power Supply / Programmable Timers 0-30 sec / NC and NO Inputs / 2 sec Pulse Outputs / Emergency Function

  • $ 1,899.00
  • Brand: Ruiz Electronics
  • Availability: In stock
  • SKU: RXC02CE

Ruiz Electronics model: RXC02CE The RXC02CE interlock controller is a professional electronic system designed for access control using two doors with electric locks. It operates exclusively in a normally locked...

Tags: categoria:Control de Acceso , Energía Y Alimentación , marca:Ruiz Electronics , proveedor:Syscom , sku:RXC02CE , supplier:Syscom , syscom

Ruiz Electronics model: RXC02CE

The RXC02CE interlock controller is a professional electronic system designed for access control using two doors with electric locks. It operates exclusively in a normally locked door mode, requiring normally closed sensors on each door and normally open buttons for unlocking. The system features programmable timers from 0 to 30 seconds for opening and closing delays, in addition to an emergency function that sequentially activates the locks. The architecture includes time protections that ensure system safety, returning to the initial state if no opening is detected within the established 30 seconds.

General Features

  • Type: 2-door interlock controller
  • Operating Mode: Normally locked doors
  • Board Power Supply: +12VDC
  • Lock Power Supply: 12VAC
  • Timers: 2 programmable selectors 0-30 sec
  • Inputs: 2 NC sensors, 2 NO buttons, 1 NO emergency
  • Outputs: 2-second pulse for locks
  • Emergency Function: Sequential activation with 3 sec pause
Electrical Specifications
  • Power Supply: +12VDC for board
  • Lock Power Supply: 12VAC
  • Sensor Inputs: Normally Closed (dry contact)
  • Button Inputs: Normally Open (dry contact)
  • Outputs: 2-second pulse for locks
  • Emergency Relay: Remains activated during emergency
Timing and Control
  • Selector1: Button→unlock time (0-30 sec)
  • Selector2: Time before locking (0-30 sec)
  • Lock Pulse: 2 seconds
  • Retry: 3 seconds if opening is not detected
  • Timeout: 30 seconds maximum
  • Emergency: Sequential activation 2s ON / 3s OFF
Terminals and Connections
  • +12V-: 12VDC input
  • S1, S2: NC sensors 1 and 2
  • B1, B2: NO buttons 1 and 2
  • E: NO emergency button
  • Vo1, Vo2: Outputs 1 and 2
  • VAC: 12VAC lock power supply
  • NC, C, NA: Relay contacts
Timing Table
  • SW1-SW4: Binary selectors (0-30 sec)
  • 0000: 0 seconds
  • 0001: 2 seconds
  • 0010: 4 seconds
  • 0011: 6 seconds
  • 0100: 8 seconds
  • 0101: 10 seconds
  • 0110: 12 seconds
  • 0111: 14 seconds
  • 1000: 16 seconds
  • 1001: 18 seconds
  • 1010: 20 seconds
  • 1011: 22 seconds
  • 1100: 24 seconds
  • 1101: 26 seconds
  • 1110: 28 seconds
  • 1111: 30 seconds
Operation
  • Normal Mode: B1/B2 → door unlock → close detection
  • Timeout: 30 seconds without opening → initial state
  • Retry: 3 seconds without detection → repeat pulse
  • Emergency: E activated → Vo1/Vo2 sequence 2s ON / 3s OFF
  • Relay E: Remains ON during emergency
Recommendations
  • Transformer: 12VAC, 2.5A (RT1230LS)
  • Lock: Electric 12VAC (ACCESSRIM)
  • Sensors: Normally Closed
  • Buttons: Normally Open
  • Connections: Dry contact


Recently viewed