Emergency Interface for Plant with Electric Generator
Emergency Interface for Plant with Electric Generator
Couldn't load pickup availability
Operation
The device is basically a relay that, in its normal state, is powered by plug A (as any device would normally be powered), but in the event of a power outage, the power source quickly switches to plug B (approx. 15 ms) to prevent equipment from shutting down.
Specifications
- Input voltage: 110 VAC 50/60 Hz
- Plug A input type: Nema 5-15P (connected to utility grid, constant power)
- Plug B input type: Nema 5-15P (connected to backup system: typically batteries + inverter)
- Output voltage: 110 VAC 50/60 Hz
- Output type: 4 x Nema 5-15R
- Maximum output current: 20 A total across 4 outlets.
- Switching Voltage: 75 VAC ± 5 VAC.
- Power switchover time: 15-20 ms.
Safety Notes
- When operating with grid power, the PETRANSFER is transparent: it provides the same electrical values already present in the network.
- A system with PETRANSFER does not provide voltage correction, nor does it include protection against transient spikes or overvoltages.
- A PETRANSFER has a switching voltage of 77 to 75 VAC; therefore, an undervoltage could enter your system and potentially damage sensitive equipment.
Technical Note
It should only be used when the plug powering the main system provides a clean signal, a constant voltage, and includes proper grounding and protection against permanent and transient overvoltages suitable for the environment, and on the B side (emergency), a system that offers the same conditions.
The cable closest to the contacts is the one that goes to the inverter or backup system (circled in red). The other is connected to the permanent electrical power line.