SYSCOM TOWERS
12m Guyed Floor Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wire not included).
12m Guyed Floor Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wire not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standard
- High elevation / Low cost
- 100% Section-by-Section Assembly Inspection
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
- Ideal for high-humidity coastal areas or industrial zones
Physical Characteristics
- Maximum Axial Load: 500 Kg
- Height: 12 meters (4 sections)
- Wind resistance: 200 km/hr
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid Areas)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 4 | STZ45G | Tower section with 45 cm face width |
| 1 | SCZ45G | 45 cm tower top with lightning rod clamp |
| 1 | SBZ45G | 45 cm tower base |
| 1 | SAB45G | Tower base anchor 35/45 |
| 2 | SJB45G | Guy wire bracket |
| 3 | SAZ45G | Ground anchor for guy wire |
| 12 | CUELLO-14-HDG | Guy wire thimble |
| 36 | NUDO-14-FJG | 1/4' wire rope clip |
Does not include guy wire.
95 meters of 1/4' guy wire (SRET-635-CAM) or larger diameters are recommended.
Does not include turnbuckles.
6 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
**Failure to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy Anchors will void the equipment warranty, and any additional modifications are the sole responsibility of the installer.**
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction lamp |
* Signaling standards dictate that the tower must be painted in 7 stripes of equal size; 4 stripes in reddish-orange and 3 in white.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 15 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged wire rope clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety carriage for installer |
| 1 | SYS-USA7B | (Optional) Full body harness |
*NOM-009 mandates the use of fall arrest systems on a structure.
Grounding system recommended for tower and mounted equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Ground bus bar with insulators, 1000A capacity (without cabinet) |
* We recommend using 4 AWG copper-clad cable (SLY-287-GRN) for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic lightning rod system recommended for tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With a bag of impedance improvement compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection box |
| 1 | ANTIOX | Terminal protection spray |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 8 | TGAC114 | Tower insulator |
*The dipole-type tip offers a 72° cone of protection below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan for checking guy wire tension and tightening hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in an orange-red and white tone, in 7 stripes of equal height, starting and ending in orange-red (SYSCOM does not perform tower painting work)
- It is recommended to illuminate the tower at least at the tip with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images