SYSCOM TOWERS
15 m Floor-Mounted Guyed Tower Kit with Galvanized STZ30 Section (Guy wires not included).
15 m Floor-Mounted Guyed Tower Kit with Galvanized STZ30 Section (Guy wires not included).
Couldn't load pickup availability
Highlighted Features
- Standard: ISO 9001:2015
- High Elevation / Low cost
- 100% Inspection of Section-by-Section Assembly
- Galvanization: Electrolytic (ASTM B-633)
- Application: Dry, corrosion-free areas
Physical Characteristics
- Maximum Axial Load: 200 kg
- Height: 15 meters (5 sections)
- Wind Resistance: 200 km/h
- Anti-corrosive Protection: Electrolytic Galvanization (ASTM B-633)
- Application: Outdoor (Desert areas or low humidity)
- 5 x STZ30 - Tower section, 30 cm face width
- 1 x SCZ30P - 30 cm tower top with lightning rod clamp
- 1 x SBA30 - 30 cm tower base
- 1 x SAB30 - Tower base anchor
- 3 x SJB30 - Guy wire attachment flange
- 3 x SAP02 - Floor anchor for guy wire
- 18 x CUELLO-14-HDG - Guy wire thimble
- 54 x NUDO-316-FJG - 3/16' wire rope clip
Not included: Guy wire (we recommend 160 meters of SRET-318-CAM)
Not included: Turnbuckles (we recommend 9 TEN1/2X6OGJ or TEN1/2X6OQJ)
**Do not use installation accessories such as flanges, tower base, tower anchor, or guy anchors; doing so will void the equipment warranty**
- 1 x SHE-LV - Pair of mounting brackets
- 1 x S-GULV - Line guide
- 18 x SRET-338CAM - 3/8' cable
- 6 x NUDO-38FJG - 3/8' forged clip
- 2 x CUELLO-38-HDG - 3/8' thimble
- 1 x TRY-ACC-SLIDER - Safety slider for installer (Optional)
- 1 x SYS-USA7B - Suspension harness (Optional)
*NOM-009 mandates the use of fall arrest systems on structures
- 1 x TG45AB - 45 A grounding electrode with electrode, filter, and H2Ohm compound
- 1 x S610 - Plastic inspection well
- 3 x TGCR11 - Eye connector
- 2 x TGAB18 - Rod connector
- 1 x TGBUSG10 - 1000A capacity ground bus bar with insulators (without enclosure)
*We recommend using 4 AWG jacketed copper cable (SLY-287-GRN) for electrode grounding to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) may be used
- 1 x TGTDPC - Lightning rod with aluminum mast (MASTIL1.2)
- 1 x TG45AB - 45 Amp electrode with bag of impedance-improving compound (H2OHM), compass, and level
- 1 x S610 - Small plastic inspection well
- 1 x ANTIOX - Spray for terminal protection
- 3 x TGCR11 - Eye connector
- 2 x TGAB18 - Rod connector
- 10 x TGAC - Tower insulator
*The dipole-type rod offers a 72° cone of protection below the coil. Recommended for low lightning incidence zones
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used
Recommendations
- Ensure installation is performed by a trained professional
- Schedule a maintenance plan for checking guy wire tension and adjusting fasteners
- Do not install solar panels at a height greater than 6 meters. Verify compatibility between solar cells and mounts
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torque and bending, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red
- It is recommended to light the tower at least at the tip with a red lamp
Lightning Protection + Grounding Kit
KLP-TZ15-PRO - Complete kit ideal for 15m towers with corona dipole, cabling, and electrodes
Or you can quote the Grounding or Lightning Protection components individually
Installation Images