15 m Guyed Tower Kit with Galvanized STZ35 Section (Guy wires not included).
15 m Guyed Tower Kit with Galvanized STZ35 Section (Guy wires not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standard
- High Elevation / Low cost
- 100% Section-by-Section Assembly Inspection
- Electrolytic galvanization according to ASTM B-633 standard
- Ideal for dry, corrosion-free areas
Physical Characteristics
- Maximum Axial Load: 350 Kg
- Height: 15 meters (5 sections)
- Wind resistance: 200 km/h
- Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633)
- Application: Outdoor (Desert or low-humidity areas)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 5 | STZ35 | 35 cm face width tower section |
| 1 | SCZ35P | 35 cm tower top cap with lightning rod clamp |
| 1 | SBZ35 | 35 cm tower base |
| 1 | SAB45 | Anchor for 35/45 tower base |
| 2 | SJB35 | Guy wire attachment bracket |
| 3 | SAZ45 | Floor anchor for guy wire |
| 12 | CUELLO-14-HDG | Thimble for guy wire |
| 36 | NUDO-316-FJG | 3/16' cable clamp |
Does not include guy wire. 115 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.
Does not include turnbuckles. 6 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
Failure to use installation accessories such as Brackets, Tower Base, Tower Anchor, or Guy Anchors is considered a voidance of the equipment warranty, and any additional modifications remain the responsibility of the installer.
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Self-contained LED strobe with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mounting for EIGSLSE obstruction light |
* The signaling standard dictates that the tower must be painted in 7 strips of equal size; 4 strips in reddish-orange and 3 in white.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of attachment brackets |
| 1 | S-GULV | Line guide |
| 18 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged cable clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety Slider for Installer |
| 1 | SYS-USA7B | (Optional) Suspension Harness |
* NOM-009 makes the use of systems that arrest accidental falls on a structure mandatory.
Recommended Grounding System for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with Electrode, Filter, and H2Ohm compound |
| 1 | S610 | Plastic inspection well |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Grounding bus bar with insulators, 1000A capacity (Without cabinet) |
* The use of 4 AWG coated copper cable (SLY-287-GRN) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Recommended Basic Lightning Rod System for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode with one bag of impedance improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection well |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 10 | TGAC114 | Tower insulator |
*The dipole-type rod offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for the integration (SLY-346-BLK). Considering an installation of the electrode at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and adjust hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting work)
- It is recommended to illuminate the tower at least at the tip with a red light
Representative Diagram: Guy Wire Installation Version 2.0