SYSCOM TOWERS
15m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wires not included).
15m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wires not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standards.
- High elevation / Low cost.
- 100% section-by-section assembly inspection.
- Hot-dip galvanized according to NMX-H-004-SCFI-2008.
- Ideal for high-humidity coastal zones or industrial areas.
Physical Characteristics
- Maximum Axial Load: 350 kg.
- Height: 15 meters (5 sections).
- Wind Resistance: 200 km/h.
- Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoor (Humid zones).
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 5 | STZ35G | 35 cm face width tower section. |
| 1 | SCZ35PG | 35 cm tower top with lightning rod clamp. |
| 1 | SBZ35G | 35 cm tower base. |
| 1 | SAB45G | Anchor for 35/45 tower base. |
| 2 | SJB35G | Guy wire support clamp. |
| 3 | SAZ45G | Floor anchor for guy wire. |
| 12 | CUELLO-14-HDG | Thimble for guy wire |
| 36 | NUDO-316-FJG | 3/16' wire rope clip. |
Does not include guy wire. 115 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.
Does not include turnbuckles. 6 turnbuckles of 5/8' x 9' (TEN5/8X9OGJ or TEN5/8X9OQJ) are recommended.
Complementary accessories (Not included)
*Failure to use installation accessories such as clamps, tower base, tower anchor, or guy anchors is considered a voiding of the equipment warranty, and any additional modifications are the responsibility of the installer.
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810. |
| 2 | HLU3R2 | Mounting for EIGSLSE obstruction light |
*Signaling regulations dictate that the tower must be painted in 7 strips of equal size; 4 strips in reddish-orange and 3 in white.
Lifeline System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 18 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged rope clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety carriage for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Grounding System Recommended for Tower and Mounted Equipment (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Grounding bus bar with insulators, 1000A capacity (without cabinet) |
*The use of 4 AWG jacketed copper wire (SLY-287-GRN) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic Lightning Protection System Recommended for Tower (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With one bag of impedance improvement compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic access box. |
| 1 | ANTIOX | Aerosol for terminal protection. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 10 | TGAC114 | Tower insulator. |
*The dipole-type tip offers a 72° protection cone under the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure that the installation is performed by a trained professional.
- Schedule a maintenance plan for checking guy wire tension and tightening hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress analysis must be performed when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
- The tower must be painted in an orange-red and white tone, in 7 stripes of equal height starting and ending in orange-red (SYSCOM does not perform tower painting work).
- It is recommended to illuminate the tower at least at the top with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images