SYSCOM TOWERS
15 m Ground-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).
15 m Ground-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standards
- High Elevation / Low cost
- 100% Assembly Inspection, Section by Section
- Hot-Dip Galvanized in accordance with NMX-H-004-SCFI-2008
- Ideal for high-humidity coastal zones or industrial areas
Physical Characteristics
- Maximum Axial Load: 500 Kg
- Height: 15 meters (5 sections)
- Wind resistance: 200 km/hr
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid Zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 5 | STZ45G | 45 cm face width tower section |
| 1 | SCZ45G | 45 cm tower top with lightning rod set screw |
| 1 | SBZ45G | 45 cm tower base |
| 1 | SAB45G | Anchor for 35/45 tower base |
| 2 | SJB45G | Guy wire clamp flange |
| 3 | SAZ45G | Ground anchor for guy wire |
| 12 | CUELLO-14-HDG | Thimble for guy wire |
| 36 | NUDO-14-FJG | 1/4' wire rope clip |
Guy wire not included. 115 meters of 1/4' guy wire (SRET-635-CAM) or larger diameters are recommended.
Turnbuckles not included. 6 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction lamp |
* The signaling standard dictates that the tower must be painted in 7 equal-sized bands; 4 reddish-orange bands and 3 white ones.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 18 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged rope clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
*NOM-009 mandates the use of fall arrest systems when working on a structure.
Recommended Grounding System for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with Electrode, Filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity ground bus bar with insulators (Without cabinet) |
* It is recommended to use 4 AWG coated copper cable (SLY-287-GRN) for electrode grounding to the tower. For equipment on the tower, 6 AWG can be used (SLY-291-GRN).
Recommended Basic Lightning Protection System for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With one bag of impedance-improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic access box |
| 1 | ANTIOX | Terminal protection spray |
| 3 | TGCR11 |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.
Recommendations
- Ensure the installation is performed by a trained professional
- Schedule a maintenance plan for checking guy wire tension and adjusting hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when placing an eccentric load on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting work)
- It is recommended to illuminate the tower at least at the tip with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM