Wishlist

18m Ground-Mounted Guyed Tower Kit with Galvanized STZ30 Section (Guy wire not included).

  • $ 16,699.00
  • Brand: SYSCOM TOWERS
  • Availability: 1 In stock
  • SKU: KTZ-30E-018

Key Features Product manufactured under ISO 9001:2015 standards High Elevation / Low cost 100% Inspection of section-by-section assembly Electrolytic galvanization according to ASTM B-633 standards Ideal for dry, corrosion-free zones...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30E-018 , supplier:Syscom , syscom

SYSCOM TOWERS Logo

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • High Elevation / Low cost
  • 100% Inspection of section-by-section assembly
  • Electrolytic galvanization according to ASTM B-633 standards
  • Ideal for dry, corrosion-free zones

Physical Characteristics

  • Maximum Axial Load: 200 Kg
  • Height: 18 meters (6 sections)
  • Wind Resistance: 200 km/h
  • Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633)
  • Application: Outdoor (Desert or low humidity areas)

Includes the following components

Quantity Model Description
6 STZ30 Tower section with 30 cm face width
1 SCZ30P 30 cm tower top with lightning rod set screw
1 SBA30 30 cm tower base
1 SAB30 Tower base anchor
3 SJB30 Guy wire clamp collar
3 SAP02 Ground anchor for guy wire
18 CUELLO-14-HDG Guy wire thimble
54 NUDO-316-FJG 3/16' cable clip

Does not include guy wire. We recommend 190 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters.

Does not include turnbuckles. We recommend 9 turnbuckles of 1/2' x 6'. (TEN1/2X6OGJ or TEN1/2X6OQJ)

**Failure to use installation accessories such as collars, tower base, tower anchor, or guy wire anchors is considered a voiding of the equipment warranty, and any additional adaptation is the installer's responsibility.**

Complementary accessories (Not included)

Signaling/Lighting System (Not included)

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. Type L810
2 HLU3R2 Mount for EIGSLSE obstruction lamp

*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 reddish-orange bands and 3 white bands.

Lifeline system (Not included)

Quantity Model Description
1 SHE-LV Pair of mounting brackets
1 S-GULV Line guide
20 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged cable clip
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer
1 SYS-USA7B (Optional) Full-body harness

*NOM-009 mandates the use of fall arrest systems when working on a structure.

New! Lightning rod + Grounding kit with cable. LINKEDPRO brand (Not included)

KLP-TZ18-PRO. - All included! Ideal for 18m towers, with dissipation array, wiring, and electrodes.

Alternatively, you can quote the following individual grounding or lightning rod components:

Recommended Grounding System for Tower and Mounted Equipment (Not included)

Quantity Model Description
1 TG45AB 45A grounding electrode with filter and H2Ohm compound
1 S610 Plastic access box
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 Grounding bus bar with insulators, 1000A capacity (without cabinet)

* We recommend using 4 AWG jacketed copper wire (SLY-287-GRN) for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Recommended Basic Lightning Rod System for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning rod tip with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp. electrode with one bag of impedance-improving compound (H2OHM), compass, and level.
1 S610 Small plastic inspection well
1 ANTIOX Aerosol for terminal protection
3 TGCR11 Eye terminal connector
2 TGAB18 Ground rod connector
12 TGAC Tower insulator

*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence

*2/0 gauge copper cable is recommended for the integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used

View physical ground + lightning rod connection diagram

Recommendations

  • Ensure that the installation is performed by a trained professional
  • Schedule a maintenance plan to check guy wire tension and tighten hardware
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
  • A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, resulting in structural failure
  • The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting)
  • It is recommended to illuminate the tower at least at the tip with a red lamp

Representative Diagram: Guy Installation Version 2.0

Guy Installation Diagram Version 2.0

Installation Images

Installation Images

Recently viewed