18m Ground-Mounted Guyed Tower Kit with Galvanized STZ30 Section (Guy wire not included).
- $ 16,699.00
- Brand: SYSCOM TOWERS
- Availability: 1 In stock
- SKU: KTZ-30E-018
Key Features Product manufactured under ISO 9001:2015 standards High Elevation / Low cost 100% Inspection of section-by-section assembly Electrolytic galvanization according to ASTM B-633 standards Ideal for dry, corrosion-free zones...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30E-018 , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 standards
- High Elevation / Low cost
- 100% Inspection of section-by-section assembly
- Electrolytic galvanization according to ASTM B-633 standards
- Ideal for dry, corrosion-free zones
Physical Characteristics
- Maximum Axial Load: 200 Kg
- Height: 18 meters (6 sections)
- Wind Resistance: 200 km/h
- Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633)
- Application: Outdoor (Desert or low humidity areas)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 6 | STZ30 | Tower section with 30 cm face width |
| 1 | SCZ30P | 30 cm tower top with lightning rod set screw |
| 1 | SBA30 | 30 cm tower base |
| 1 | SAB30 | Tower base anchor |
| 3 | SJB30 | Guy wire clamp collar |
| 3 | SAP02 | Ground anchor for guy wire |
| 18 | CUELLO-14-HDG | Guy wire thimble |
| 54 | NUDO-316-FJG | 3/16' cable clip |
Does not include guy wire. We recommend 190 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters.
Does not include turnbuckles. We recommend 9 turnbuckles of 1/2' x 6'. (TEN1/2X6OGJ or TEN1/2X6OQJ)
**Failure to use installation accessories such as collars, tower base, tower anchor, or guy wire anchors is considered a voiding of the equipment warranty, and any additional adaptation is the installer's responsibility.**
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction lamp |
*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 reddish-orange bands and 3 white bands.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 20 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged cable clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Full-body harness |
*NOM-009 mandates the use of fall arrest systems when working on a structure.
New! Lightning rod + Grounding kit with cable. LINKEDPRO brand (Not included)
KLP-TZ18-PRO. - All included! Ideal for 18m towers, with dissipation array, wiring, and electrodes.
Alternatively, you can quote the following individual grounding or lightning rod components:
Recommended Grounding System for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with filter and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Grounding bus bar with insulators, 1000A capacity (without cabinet) |
* We recommend using 4 AWG jacketed copper wire (SLY-287-GRN) for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Recommended Basic Lightning Rod System for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp. electrode with one bag of impedance-improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic inspection well |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye terminal connector |
| 2 | TGAB18 | Ground rod connector |
| 12 | TGAC | Tower insulator |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence
*2/0 gauge copper cable is recommended for the integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used
Recommendations
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, resulting in structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting)
- It is recommended to illuminate the tower at least at the tip with a red lamp
Representative Diagram: Guy Installation Version 2.0
Installation Images