Wishlist

18 m Height Guyed Floor Tower Kit with Hot-Dip Galvanized STZ30G Section. (Guy wires not included).

  • $ 25,099.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-30G-018

Key Features Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% section-by-section assembly inspection Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008 Ideal for high-humidity coastal zones or industrial...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-30G-018 , supplier:Syscom , syscom

Logo SYSCOM TOWERS

Key Features

  • Product manufactured under ISO 9001:2015 standards
  • High elevation / Low cost
  • 100% section-by-section assembly inspection
  • Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
  • Ideal for high-humidity coastal zones or industrial areas

Physical Characteristics

  • Maximum Axial Load: 200 kg
  • Height: 18 meters (6 sections)
  • Wind Resistance: 200 km/h
  • Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
  • Application: Outdoor (Humid zones)

Includes the following components

Quantity Model Description
6 STZ30G 30 cm face width tower section
1 SCZ30PG 30 cm tower top with lightning rod clamp
1 SBA30G Base for 30 cm tower
1 SAB30G Tower base anchor
3 SJB30G Guy wire support flange
3 SAP02G Ground anchor for guy wire
18 CUELLO-14-HDG Thimble for guy wire
54 NUDO-316-FJG 3/16' wire rope clip

Guy wire not included.

We recommend 190 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters.

Turnbuckles not included.

We recommend 9 turnbuckles of 1/2' x 6'. (TEN1/2X6OGJ or TEN1/2X6OQJ).

**NOT using installation accessories such as flanges, tower bases, tower anchors, or guy anchors is considered a voiding of the equipment warranty, and any additional modifications are the sole responsibility of the installer.**

Complementary accessories (Not included)

Signaling/Lighting System (Not included):

Quantity Model Description
2 EIGSLSE Autonomous LED strobe with photocell, solar panel, and battery. Type L810
2 HLU3R2 Mount for EIGSLSE obstruction lamp

* Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 orange-red bands and 3 white bands.

Lifeline system (Not included)

Quantity Model Description
1 SHE-LV Pair of mounting hardware
1 S-GULV Line guide
20 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged cable clip
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer
1 SYS-USA7B (Optional) Full body harness

*NOM-009 mandates the use of systems that arrest accidental falls on a structure.

New! Lightning Rod Kit + Grounding with cable. Brand: LINKEDPRO (Not included)

KLP-TZ18-PRO. - All-inclusive! Ideal for 18m towers with crown dipole, wiring, and electrodes.

Alternatively, you can quote the following individual grounding or lightning rod components:

Recommended Grounding System for Tower and tower-mounted equipment (Not included):

Quantity Model Description
1 TG45AB 45A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic junction box
3 TGCR11 Eye bolt connector
2 TGAB18 Rod connector
1 TGBUSG10 1000A capacity grounding busbar (no cabinet)

* We recommend using 4 AWG jacketed copper wire (SLY-287-GRN) for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.

Recommended Basic Lightning Rod System for Tower (Not included)

Quantity Model Description
1 TGTDPC Lightning Rod Tip with Aluminum Mast (MASTIL1.2)
1 TG45AB 45 Amp Electrode with a bag of impedance-improving compound (H2OHM), compass, and level
1 S610 Small plastic inspection box
1 ANTIOX Aerosol for terminal protection
3 TGCR11 Eye bolt connector
2 TGAB18 Rod connector
12 TGAC Tower insulator

*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.

*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an installation of the electrode at a maximum of 3 meters from the tower, approximately 8 meters are used.

See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.

Recommendations

  • Ensure the installation is performed by a trained professional
  • Schedule a maintenance plan for checking guy wire tension and adjusting fasteners
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
  • A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure
  • The tower must be painted in orange-red and white, in 7 bands of equal height starting and ending in orange-red (SYSCOM does not perform tower painting work)
  • It is recommended to illuminate the tower, at least at the top, with a red lamp

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram

Installation Images

Installation Images

Recently viewed