SYSCOM TOWERS
18m Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wire not included).
18m Guyed Tower Kit with STZ35G Hot-Dip Galvanized Section (Guy wire not included).
Couldn't load pickup availability
Key Features:
- Product manufactured under ISO 9001:2015 standard
- High elevation / Low cost
- 100% section-by-section assembly inspection
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
- Ideal for coastal areas with high humidity or industrial zones
Physical Characteristics:
- Maximum Axial Load: 350 kg
- Height: 18 meters (6 sections)
- Wind resistance: 200 km/hr
- Anti-corrosion protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid zones)
Includes the following components:
| Quantity | Model | Description |
|---|---|---|
| 6 | STZ35G | Tower section with 35 cm face width |
| 1 | SCZ35PG | 35 cm tower top with lightning rod clamp |
| 1 | SBZ35G | 35 cm tower base |
| 1 | SAB45G | Anchor for 35/45 tower base |
| 2 | SJB35G | Guy wire clamp |
| 3 | SAZ45G | Ground anchor for guy wire |
| 12 | CUELLO-14-HDG | Thimble for guy wire |
| 36 | NUDO-316-FJG | 3/16' cable clamp |
Guy wire not included. 130 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.
Turnbuckles not included. 6 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
**FAILURE to use installation accessories such as clamps, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the responsibility of the installer.**
Complementary accessories (Not included):
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe light with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
* Signaling standards dictate that the tower must be painted in 7 stripes of equal size; 4 orange-red stripes and 3 white stripes.
Lifeline System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 21 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged cable clamp |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
*NOM-009 mandates the use of systems to prevent accidental falls on a structure.
Grounding System Recommended for the Tower and Mounted Equipment (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with Electrode, Filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity busbar with insulators (without cabinet) |
* It is recommended to use 4 AWG coated copper cable (SLY-287-GRN) for electrode grounding to the tower. For equipment on the tower, 6 AWG cable (SLY-291-GRN) can be used.
Basic Lightning Protection System Recommended for Tower (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With a bag of impedance improvement compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection housing |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 12 | TGAC114 | Tower insulator |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended to perform the integration (SLY-346-BLK). Considering an installation of the electrode at a maximum of 3 meters from the tower, approx. 8 meters are used.
DIAGRAM for physical grounding + lightning rod connection
Recommendations:
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan for checking guy wire tension and adjusting fasteners
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform the tower painting work)
- It is recommended to illuminate the tower at least at the top with a red light
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images