SYSCOM TOWERS
18m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).
18m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 Standards
- High Elevation / Low cost
- 100% Assembly Inspection Section by Section
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008
- Ideal for high-humidity coastal areas or industrial zones
Physical Characteristics
- Maximum Axial Load: 500 kg
- Height: 18 meters (6 sections)
- Wind Resistance: 200 km/h
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 6 | STZ45G | Tower section 45 cm face width |
| 1 | SCZ45G | 45 cm tower top cap with lightning rod set screw |
| 1 | SBZ45G | 45 cm tower base |
| 1 | SAB45G | Anchor for 35/45 tower base |
| 2 | SJB45G | Guy wire bracket |
| 3 | SAZ45G | Ground anchor for guy wire |
| 12 | CUELLO-14-HDG | Thimble for guy wire |
| 36 | NUDO-14-FJG | 1/4' wire rope clip (dog type) |
Guy wire not included. 130 meters of 1/4' guy wire (SRET-635-CAM) or larger diameters are recommended.
Turnbuckles not included. 6 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
Complementary accessories (Not included)
*Failure to use installation accessories such as brackets, tower base, tower anchor, or guy anchors is considered a voiding of the equipment warranty, and any additional adaptation is the responsibility of the installer.
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. L810 type |
| 2 | HLU3R2 | Mounting for EIGSLSE obstruction light |
*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 reddish-orange bands and 3 white bands.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of fastening fittings |
| 1 | S-GULV | Line guide |
| 21 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
*NOM-009 mandates the use of systems to arrest accidental falls on a structure.
Recommended Grounding System for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Grounding bus bar with insulators, 1000A capacity (without cabinet) |
* The use of 4 AWG jacketed copper wire (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic Lightning Rod System Recommended for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode. With a bag of impedance improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic handhole |
| 1 | ANTIOX | Terminal protection spray |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 12 | TGAC114 | Tower insulator |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering the electrode is installed at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting work)
- It is recommended to light the tower, at least at the tip, with a red lamp
Representative Diagram: Guy Installation Version 2.0
Installation Images