Key Features
- Product manufactured under ISO 9001:2015 standards
- High Elevation / Low cost
- 100% Section-by-Section Assembly Inspection
- Electrolytic galvanization according to ASTM B-633 standards
- Ideal for dry, corrosion-free areas
Physical Characteristics
- Maximum Axial Load: 200 kg
- Height: 21 meters (7 sections)
- Wind resistance: 200 km/hr
- Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633)
- Application: Outdoor (Desert or low-humidity areas)
Includes the following components
| Quantity | Model | Description |
| 7 | STZ30 | 30 cm face tower section |
| 1 | SCZ30P | 30 cm tower top with lightning rod set screw |
| 1 | SBA30 | 30 cm tower base |
| 1 | SAB30 | Tower base anchor |
| 4 | SJB30 | Guy wire clamp |
| 3 | SAP02 | Ground anchor for guy wire |
| 24 | CUELLO-14-HDG | Thimble for guy cable |
| 72 | NUDO-316-FJG | 3/16' cable clamp |
Guy cable not included
290 meters of 1/8' guy cable (SRET-318-CAM) or larger diameters are recommended
Turnbuckles not included
12 turnbuckles of 1/2' x 6' are recommended. (TEN1/2X6OGJ or TEN1/2X6OQJ)
Failure to use installation accessories such as clamps, tower base, tower anchor, or guy wire anchors will result in the loss of the equipment warranty, and any additional adaptation is the installer's responsibility
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mounting for EIGSLSE obstruction light |
* Signaling standards dictate that the tower must be painted in 7 equal bands; 4 in orange-red and 3 in white
Lifeline system (Not included)
* NOM-009 mandates the use of fall protection systems for structures
Recommended Grounding System for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
| 1 | TG45AB | 45 A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Bonding bar with insulators, 1000A capacity (without cabinet) |
* It is recommended to use 4 AWG jacketed copper wire (SLY-287-GRN) for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Recommended Basic Lightning Protection System for Tower (Not included)
| Quantity | Model | Description |
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp. electrode with a bag of impedance-improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic access box |
| 1 | ANTIOX | Spray for terminal protection |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 14 | TGAC | Insulator for tower |
The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.
Recommendations
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan to check guy wire tension and tighten hardware
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
- A stress study must be conducted when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure
- The tower must be painted in orange-red and white, in 7 stripes of equal height, starting and ending with orange-red (SYSCOM does not perform tower painting)
- It is recommended to illuminate the tower at least at the top with a red lamp