SYSCOM TOWERS
21 m Floor-Mounted Guyed Tower Kit with STZ30G Hot-Dip Galvanized Section (guy wires not included).
21 m Floor-Mounted Guyed Tower Kit with STZ30G Hot-Dip Galvanized Section (guy wires not included).
Couldn't load pickup availability
Key Features
- Product manufactured under ISO 9001:2015 standards.
- High elevation / Low cost.
- 100% assembly inspection section by section.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for high-humidity coastal zones or industrial areas.
Physical Characteristics
- Maximum Axial Load: 200 Kg.
- Height: 21 meters (7 sections).
- Wind Resistance: 200 km/hr.
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoor (Humid zones).
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 7 | STZ30G | Tower section with 30 cm face width. |
| 1 | SCZ30PG | 30 cm tower top with set screw for lightning rod. |
| 1 | SBA30G | Base for 30 cm tower. |
| 1 | SAB30G | Anchor for tower base. |
| 4 | SJB30G | Guy wire attachment flange. |
| 3 | SAP02G | Floor anchor for guy wire. |
| 24 | CUELLO-14-HDG | Thimble for guy wire |
| 72 | NUDO-316-FJG | 3/16' wire rope clip. |
Does not include guy wire. 290 meters of 1/8' guy wire (SRET-318-CAM) or larger diameters are recommended.
Does not include turnbuckles. 12 turnbuckles of 1/2' x 6' are recommended. (TEN1/2X6OGJ or TEN1/2X6OQJ).
* NOT using installation accessories such as flanges, tower base, tower anchor, or guy wire anchors is considered a forfeiture of the equipment warranty, and any additional adaptation is the sole responsibility of the installer.
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 24 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged wire rope clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
* NOM-009 mandates the use of systems that prevent accidental falls on a structure.
New! Lightning Rod Kit + Grounding with Cable. Brand: LINKEDPRO (Not included)
KLP-TZ21-PRO. - All inclusive! Ideal for 21m towers with corona dipole, wiring, and electrodes.
Or you can quote the following Grounding or Lightning Rod components individually:
Recommended Grounding System for Tower and mounted equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | 1000A capacity ground bus bar with insulators (No cabinet) |
* 4 AWG insulated copper cable (SLY-287-GRN) is recommended for grounding from the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Recommended Basic Lightning Rod System for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod tip with aluminum mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic access box. |
| 1 | ANTIOX | Terminal protection spray. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
*The dipole-type tip offers a 72° protection cone under the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used.
See the Grounding + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations
- Ensure the installation is performed by a trained professional.
- Schedule a maintenance plan to check guy wire tension and tighten hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress analysis must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure.
- The tower must be painted in orange-red and white tones, in 7 stripes of equal height, starting and ending in orange-red (SYSCOM does not perform tower painting services).
- It is recommended to illuminate the tower at least at the tip with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images