Wishlist

21m Floor-Mounted Guyed Tower Kit with Galvanized STZ35 Section (Guy wires not included).

  • $ 32,999.00
  • Brand: SYSCOM TOWERS
  • Availability: In stock
  • SKU: KTZ-35E-021

Key Features: Product manufactured under ISO 9001:2015 standards High elevation / Low cost 100% assembly inspection section by section Electrolytic galvanization in accordance with ASTM B-633 standards Ideal for dry,...

Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35E-021 , supplier:Syscom , syscom

Logo SYSCOM TOWERS

Key Features:

  • Product manufactured under ISO 9001:2015 standards
  • High elevation / Low cost
  • 100% assembly inspection section by section
  • Electrolytic galvanization in accordance with ASTM B-633 standards
  • Ideal for dry, corrosion-free areas

Physical Specifications:

  • Maximum Axial Load: 350 kg
  • Height: 21 meters (7 sections)
  • Wind Resistance: 200 km/h
  • Anti-corrosive protection: Electrolytic Galvanization (ASTM B-633)
  • Application: Outdoor (Desert or low-humidity areas)

Includes the following components:

Quantity Model Description
7 STZ35 Tower section with 35 cm face width
1 SCZ35P 35 cm tower top cap with set screw for lightning rod
1 SBZ35 35 cm tower base
1 SAB45 Anchor for 35/45 tower base
3 SJB35 Guy wire clamp flange
3 SAZ45 Ground anchor for guy wire
18 CUELLO-14-HDG Thimble for guy wire
54 NUDO-316-FJG 3/16' wire rope clip

Guy wire not included. 215 meters of 3/16' guy wire is recommended (SRET-474-CAM or SRET-316-DA) or larger diameters.

Turnbuckles not included. 9 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).

**NOT using installation accessories such as flanges, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional modifications are the sole responsibility of the installer.**

Complementary accessories (Not included):

Signaling/Lighting System (Not included):

Quantity Model Description
2 EIGSLSE Self-contained LED strobe with photocell, solar panel, and battery. Type L810
2 HLU3R2 Mount for EIGSLSE obstruction lamp

*Signaling standards dictate that the tower must be painted with 7 equal-sized bands; 4 bands in international orange and 3 in white

Lifeline System (Not included):

Quantity Model Description
1 SHE-LV Pair of mounting brackets
1 S-GULV Line guide
24 SRET-338CAM 3/8' cable
6 NUDO-38FJG 3/8' forged wire rope clip
2 CUELLO-38-HDG 3/8' thimble
1 TRY-ACC-SLIDER (Optional) Safety slider for installer
1 SYS-USA7B (Optional) Suspension harness

*NOM-009 mandates the use of fall arrest systems on any structure

Physical Grounding System Recommended for Tower and Mounted Equipment (Not included):

Quantity Model Description
1 TG45AB 45A grounding electrode with electrode, filter, and H2Ohm compound
1 S610 Plastic access box
3 TGCR11 Eye connector
2 TGAB18 Rod connector
1 TGBUSG10 1000A capacity ground bus bar with insulators (no enclosure)

* Use of 4 AWG coated copper cable (SLY-287-GRN) is recommended for grounding the electrode to the tower. 6 AWG cable (SLY-291-GRN) may be used for equipment on the tower

Basic Lightning Protection System Recommended for Tower (Not included):

Quantity Model Description
1 TGTDPC Lightning rod with aluminum mast (MASTIL1.2)
1 TG45AB 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level
1 S610 Small plastic access box
1 ANTIOX Aerosol for terminal protection 3 TGCR11 Eye connector 2 TGAB18 Rod connector 14 TGAC114 Tower insulator

*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approx. 8 meters are used

See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM

Recommendations:

  • Ensure the installation is performed by a trained professional
  • Schedule a maintenance plan for checking guy wire tension and tightening hardware
  • Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts
  • A stress study must be performed when an eccentric load is placed on the tower. This can cause excessive torsion and bending in the tower, leading to structural failure
  • The tower must be painted in orange-red and white, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting work)
  • It is recommended to light the tower at least at the top with a red lamp

Representative Diagram: Guy Wire Installation Version 2.0

Guy Wire Installation Diagram Version 2.0

Installation Images

Installation Images

Recently viewed