SYSCOM TOWERS
21 m Guyed Ground Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wire not included).
21 m Guyed Ground Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wire not included).
Couldn't load pickup availability

Highlighted Features:
- Product manufactured under ISO 9001:2015 standards.
- High Elevation / Low cost.
- 100% Section-by-Section Assembly Inspection.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for coastal areas with high humidity or industrial zones.
Physical Characteristics:
- Maximum Axial Load: 350 Kg.
- Height: 21 meters (7 sections).
- Wind resistance: 200 km/h.
- Anticorrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoor (Humid zones).
Includes the following components:
- Quantity: 7 - STZ35G - Tower section with 35 cm face width.
- Quantity: 1 - SCZ35PG - 35 cm tower top with set screw for lightning rod.
- Quantity: 1 - SBZ35G - 35 cm tower base.
- Quantity: 1 - SAB45G - Anchor for 35/45 tower base.
- Quantity: 3 - SJB35G - Guy wire attachment flange.
- Quantity: 3 - SAZ45G - Floor anchor for guy wire.
- Quantity: 18 - CUELLO-14-HDG - Thimble for guy wire.
- Quantity: 54 - NUDO-316-FJG - 3/16' cable clamp.
Guy wire not included. 215 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.
Turnbuckles not included. 9 turnbuckles of 5/8' x 9' are recommended (TEN5/8X9OGJ or TEN5/8X9OQJ).
Complementary accessories (Not included):
Signaling/Lighting System (Not included):
*Signaling regulations state that the tower must be painted in 7 equal-sized bands; 4 bands in reddish-orange and 3 in white.
Lifeline system (Not included):
- Quantity: 1 - SHE-LV - Pair of mounting brackets.
- Quantity: 1 - S-GULV - Cable guide.
- Quantity: 24 - SRET-338CAM - 3/8' cable.
- Quantity: 6 - NUDO-38FJG - 3/8' forged cable clamp.
- Quantity: 2 - CUELLO-38-HDG - 3/8' thimble.
- Quantity: 1 - TRY-ACC-SLIDER - (Optional) Safety slider for installer.
- Quantity: 1 - SYS-USA7B - (Optional) Suspension harness.
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Recommended Physical Grounding System for Tower and Mounted Equipment (Not included):
*Using 4 AWG jacketed copper wire (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Recommended Basic Lightning Rod System for Tower (Not included):
- Quantity: 1 - TGTDPC - Lightning rod tip with aluminum mast (MASTIL1.2).
- Quantity: 1 - TG45AB - 45 Amp electrode with a bag of impedance-improving compound (H2OHM), compass, and level.
- Quantity: 1 - S610 - Small plastic inspection box.
- Quantity: 1 - ANTIOX - Spray for terminal protection.
- Quantity: 3 - TGCR11 - Eye connector.
- Quantity: 2 - TGAB18 - Rod connector.
- Quantity: 14 - TGAC114 - Tower insulator.
*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper wire is recommended for the integration (SLY-346-BLK). Considering an electrode installation at most 3 meters from the tower, approx. 8 meters are used.
DIAGRAM for Physical Ground + Lightning Rod connection
Recommendations:
- Ensure installation is carried out by a trained professional.
- Schedule a maintenance plan for checking guy tension and adjusting hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress study must be conducted when an eccentric load is placed on the tower. This can cause excessive torsion and bending, leading to structural failure.
- The tower must be painted in reddish-orange and white, in 7 equal-height bands starting and ending in reddish-orange (SYSCOM does not perform tower painting).
- It is recommended to illuminate the tower, at least at the top, with a red lamp.