21 m Guyed Ground Tower Kit with Hot-Dip Galvanized STZ35G Section (Guy wire not included).
- $ 41,399.00
- Brand: SYSCOM TOWERS
- Availability: In stock
- SKU: KTZ-35G-021
Highlighted Features: Product manufactured under ISO 9001:2015 standards. High Elevation / Low cost. 100% Section-by-Section Assembly Inspection. Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008. Ideal for coastal areas with high humidity...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-35G-021 , supplier:Syscom , syscom

Highlighted Features:
- Product manufactured under ISO 9001:2015 standards.
- High Elevation / Low cost.
- 100% Section-by-Section Assembly Inspection.
- Hot-dip galvanized in accordance with NMX-H-004-SCFI-2008.
- Ideal for coastal areas with high humidity or industrial zones.
Physical Characteristics:
- Maximum Axial Load: 350 Kg.
- Height: 21 meters (7 sections).
- Wind resistance: 200 km/h.
- Anticorrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008).
- Application: Outdoor (Humid zones).
Includes the following components:
Guy wire not included. 215 meters of 3/16' guy wire (SRET-474-CAM or SRET-316-DA) or larger diameters are recommended.
Turnbuckles not included. 9 turnbuckles of 5/8' x 9' are recommended (TEN5/8X9OGJ or TEN5/8X9OQJ).
Complementary accessories (Not included):
Signaling/Lighting System (Not included):
*Signaling regulations state that the tower must be painted in 7 equal-sized bands; 4 bands in reddish-orange and 3 in white.
Lifeline system (Not included):
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
Recommended Physical Grounding System for Tower and Mounted Equipment (Not included):
*Using 4 AWG jacketed copper wire (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Recommended Basic Lightning Rod System for Tower (Not included):
*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper wire is recommended for the integration (SLY-346-BLK). Considering an electrode installation at most 3 meters from the tower, approx. 8 meters are used.
DIAGRAM for Physical Ground + Lightning Rod connection
Recommendations:
- Ensure installation is carried out by a trained professional.
- Schedule a maintenance plan for checking guy tension and adjusting hardware.
- Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
- A stress study must be conducted when an eccentric load is placed on the tower. This can cause excessive torsion and bending, leading to structural failure.
- The tower must be painted in reddish-orange and white, in 7 equal-height bands starting and ending in reddish-orange (SYSCOM does not perform tower painting).
- It is recommended to illuminate the tower, at least at the top, with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images