21 m Floor-Mounted Guyed Tower Kit with Hot-Dip Galvanized STZ45G Section (Guy wires not included).
- $ 50,899.00
- Brand: SYSCOM TOWERS
- Availability: 9 In stock
- SKU: KTZ-45G-021
Key Features Product manufactured under ISO 9001:2015 standard High elevation / Low cost 100% Section-by-section assembly inspection Hot-dip galvanized according to NMX-H-004-SCFI-2008 Ideal for coastal areas with high humidity or...
Tags: categoria:Redes e IT , marca:SYSCOM TOWERS , proveedor:Syscom , Redes Y Conectividad , sku:KTZ-45G-021 , supplier:Syscom , syscom
Key Features
- Product manufactured under ISO 9001:2015 standard
- High elevation / Low cost
- 100% Section-by-section assembly inspection
- Hot-dip galvanized according to NMX-H-004-SCFI-2008
- Ideal for coastal areas with high humidity or industrial zones
Physical Characteristics
- Maximum Axial Load: 500 Kg
- Height: 21 meters (7 sections)
- Wind resistance: 200 km/hr
- Anti-corrosive protection: Hot-dip galvanized (NMX-H-004-SCFI-2008)
- Application: Outdoor (Humid zones)
Includes the following components
| Quantity | Model | Description |
|---|---|---|
| 7 | STZ45G | 45 cm face width tower section |
| 1 | SCZ45G | 45 cm tower top with lightning rod clamp |
| 1 | SBZ45G | Base for 45 cm tower |
| 1 | SAB45G | Anchor for 35/45 tower base |
| 3 | SJB45G | Guy wire clamp |
| 3 | SAZ45G | Ground anchor for guy wire |
| 18 | CUELLO-14-HDG | Thimble for guy wire |
| 54 | NUDO-14-FJG | 1/4' wire rope clip |
Does not include guy wire. 215 meters of 1/4' guy wire (SRET-635-CAM) or higher diameters are recommended.
Does not include turnbuckles. 9 turnbuckles of 5/8' x 9' are recommended. (TEN5/8X9OGJ or TEN5/8X9OQJ).
*Failure to use installation accessories such as clamps, tower base, tower anchor, or guy wire anchors results in the loss of equipment warranty, and any additional adaptation is the responsibility of the installer.
Complementary accessories (Not included)
Signaling/Lighting System (Not included)
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe light with photocell, solar panel, and battery. Type L810 |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light |
*The signaling standard dictates that the tower must be painted in 7 equal-sized bands; 4 bands in reddish-orange and 3 in white.
Lifeline system (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting brackets |
| 1 | S-GULV | Line guide |
| 24 | SRET-338CAM | 3/8' cable |
| 6 | NUDO-38FJG | 3/8' forged wire rope clip |
| 2 | CUELLO-38-HDG | 3/8' thimble |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer |
| 1 | SYS-USA7B | (Optional) Suspension harness |
*NOM-009 mandates the use of systems to arrest accidental falls on a structure.
Physical Grounding System Recommended for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45 A grounding electrode with electrode, filter, and H2Ohm compound |
| 1 | S610 | Plastic access box |
| 3 | TGCR11 | Eye connector |
| 2 | TGAB18 | Rod connector |
| 1 | TGBUSG10 | Grounding bar with insulators, 1000A capacity (without cabinet) |
* The use of 4 AWG coated copper cable (SLY-287-GRN) is recommended for connecting the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Basic Lightning Protection System Recommended for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning Rod Tip with Aluminum Mast (MASTIL1.2) |
| 1 | TG45AB | 45 Amp Electrode. Includes a bag of impedance-improving compound (H2OHM), compass, and level |
| 1 | S610 | Small plastic inspection box |
| 1 | ANTIOX | Aerosol for terminal protection |
| 3 | TGCR11 | Eye Connector |
| 2 | TGAB18 | Rod Connector |
| 14 | TGAC114 | Tower Insulator |
*The dipole-type tip offers a 72° protection cone below the coil. It is recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.
Recommendations:
- Ensure that the installation is performed by a trained professional
- Schedule a maintenance plan for checking guy wire tension and tightening hardware
- Do not install solar panels more than 6 meters high. Check for compatibility between solar cells and mounts
- A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failures
- The tower must be painted in orange-red and white tones, in 7 stripes of equal height starting and ending with orange-red (SYSCOM does not perform tower painting)
- It is recommended to illuminate the tower at least at the tip with a red lamp
Representative Diagram: Guy Wire Installation Version 2.0