SYSCOM TOWERS
24m Floor-Mounted Guyed Tower Kit with Electro-Galvanized STZ30 Section (Guy wire not included).
24m Floor-Mounted Guyed Tower Kit with Electro-Galvanized STZ30 Section (Guy wire not included).
Couldn't load pickup availability
Key Features:
- Product manufactured under ISO 9001:2015 standards.
- High elevation / Low cost.
- 100% inspection of section-by-section assembly.
- Electrolytic galvanization in accordance with ASTM B-633 standards.
- Ideal for dry, corrosion-free areas.
Physical Characteristics:
- Maximum Axial Load: 200 kg.
- Height: 24 meters (8 sections).
- Wind Resistance: 200 km/h.
- Anticorrosive Protection: Electrolytic Galvanization (ASTM B-633).
- Application: Outdoor (desert or low-humidity zones).
Includes the following components:
| Quantity | Model | Description |
|---|---|---|
| 8 | STZ30 | Tower section with 30 cm face width. |
| 1 | SCZ30P | 30 cm tower top with lightning rod set screw. |
| 1 | SBA30 | Base for 30 cm tower. |
| 1 | SAB30 | Anchor for tower base. |
| 4 | SJB30 | Guy wire bracket. |
| 3 | SAP02 | Ground anchor for guy wire. |
| 24 | CUELLO-14-HDG | Thimble for guy wire. |
| 72 | NUDO-316-FJG | 3/16" wire rope clip. |
Guy wire not included. 315 meters of 1/8" guy wire (SRET-318-CAM) or larger diameters are recommended.
Turnbuckles not included. 12 1/2" x 6" turnbuckles are recommended (TEN1/2X6OGJ or TEN1/2X6OQJ).
**Failure to use installation accessories such as brackets, tower base, tower anchor, or guy anchors will void the equipment warranty, and any additional adaptations are the responsibility of the installer.**
Complementary accessories (Not included):
Signaling/Lighting System (Not included):
| Quantity | Model | Description |
|---|---|---|
| 2 | EIGSLSE | Autonomous LED strobe with photocell, solar panel, and battery. L810 type. |
| 2 | HLU3R2 | Mount for EIGSLSE obstruction light. |
*Signaling standards dictate that the tower must be painted in 7 equal-sized bands; 4 reddish-orange bands and 3 white bands.
Lifeline system (Not included):
| Quantity | Model | Description |
|---|---|---|
| 1 | SHE-LV | Pair of mounting hardware. |
| 1 | S-GULV | Line guide. |
| 27 | SRET-338CAM | 3/8" cable. |
| 6 | NUDO-38FJG | 3/8" forged wire rope clip. |
| 2 | CUELLO-38-HDG | 3/8" thimble. |
| 1 | TRY-ACC-SLIDER | (Optional) Safety slider for installer. |
| 1 | SYS-USA7B | (Optional) Suspension harness. |
*NOM-009 mandates the use of systems that arrest accidental falls on a structure.
New! Lightning Rod + Grounding Kit with Cable. LINKEDPRO Brand (Not included)
KLP-TZ24-PRO.- All-inclusive! Ideal for 24m towers with corona dipole, wiring, and electrodes.
Or you may quote the following grounding or lightning rod components individually:
Recommended Grounding System for Tower and Mounted Equipment (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TG45AB | 45A grounding electrode with electrode, filter, and H2Ohm compound. |
| 1 | S610 | Plastic access box. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 1 | TGBUSG10 | Grounding bus bar with 1000A insulators (no cabinet). |
* 4 AWG coated copper wire (SLY-287-GRN) is recommended for grounding the electrode to the tower. For equipment on the tower, 6 AWG (SLY-291-GRN) can be used.
Recommended Basic Lightning Rod System for Tower (Not included)
| Quantity | Model | Description |
|---|---|---|
| 1 | TGTDPC | Lightning rod with aluminum mast (MASTIL1.2). |
| 1 | TG45AB | 45 Amp. electrode with one bag of impedance-improving compound (H2OHM), compass, and level. |
| 1 | S610 | Small plastic access box. |
| 1 | ANTIOX | Terminal protection spray. |
| 3 | TGCR11 | Eye connector. |
| 2 | TGAB18 | Rod connector. |
| 16 | TGAC | Tower insulator. |
*The dipole-type tip offers a 72° protection cone below the coil. Recommended for areas with low lightning incidence.
*2/0 gauge copper cable is recommended for integration (SLY-346-BLK). Considering an electrode installation at a maximum of 3 meters from the tower, approximately 8 meters are used.
See the Physical Ground + Lightning Rod connection diagram in the following DIAGRAM.
Recommendations:
Ensure that the installation is performed by a trained professional.
Schedule a maintenance plan to check guy wire tension and tighten hardware.
Do not install solar panels at a height greater than 6 meters. Check compatibility between solar cells and mounts.
A stress study must be performed when placing an eccentric load on the tower. This can cause excessive twisting and bending in the tower, leading to structural failure.
The tower must be painted in orange-red and white tones, in 7 stripes of equal height, starting and ending in orange-red (SYSCOM does not perform tower painting work).
It is recommended to illuminate the tower at least at the top with a red lamp.
Representative Diagram: Guy Wire Installation Version 2.0
Installation Images